National Instruments NI-9218 Channel Analogue Input Module
ຂໍ້ມູນຈໍາເພາະ
- ຊື່ຜະລິດຕະພັນ: NI-9218
- ປະເພດຕົວເຊື່ອມຕໍ່: LEMO ແລະ DSUB
- ປະເພດການວັດແທກ: ສະຫນັບສະຫນູນໃນຕົວສໍາລັບປະເພດຕ່າງໆ
- Sensor Excitation: ທາງເລືອກ 12V excitation
ປະເພດຕົວເຊື່ອມຕໍ່
NI-9218 ມີຫຼາຍກວ່າຫນຶ່ງປະເພດຕົວເຊື່ອມຕໍ່: NI-9218 ກັບ LEMO ແລະ NI-9218 ກັບ DSUB. ເວັ້ນເສຍແຕ່ຈະລະບຸປະເພດຂອງຕົວເຊື່ອມຕໍ່, NI-9218 ຫມາຍເຖິງທັງສອງປະເພດຕົວເຊື່ອມຕໍ່.
NI-9218 Pinout
Signals by Measurement Type
ໂໝດ | ປັກໝຸດ
1 |
|||||||||
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | |
±16 V | EX+ | — | AI-, EX- | — | — | AI+ | — | — | — | — |
±65 mV | EX+ 2 [2] | — | EX- [2] | — | — | AI+ | AI- 3 | — | — | — |
ເຕັມ-
ຂົວ |
EX+ [2] | — | EX- [2] | RS+ | RS- | AI+ | AI- | SC | SC | — |
IEPE | — | AI+ | AI- | — | — | — | — | — | — | — |
TEDS | — | T+ 4 | T- | — | — | — | — | — | — | T+ 5 |
ລາຍລະອຽດສັນຍານ
ສັນຍານ | ລາຍລະອຽດ |
AI+ | Positive analogue input signal connection |
AI- | Negative analogue input signal connection |
EX+ | Positive sensor excitation connection |
EX- | Negative sensor excitation connection |
RS+ | Positive remote sensing connection |
RS- | Negative remote sensing connection |
SC | Shunt calibration connection |
T+ | TEDS data connection |
T- | TEDS return connection |
ປະເພດການວັດແທກ
NI-9218 ສະຫນອງການສະຫນັບສະຫນູນໃນຕົວສໍາລັບປະເພດການວັດແທກຕໍ່ໄປນີ້.
- ±16 V
- ±65 mV
- Full-Bridge
- IEPE
- NI-9218 with LEMO only.
- Optional sensor excitation.
- Tie to pin 3.
- TEDS Class 1 data connection.
- TEDS Class 2 data connection.
ເຄັດລັບ NI recommends using the NI-9982 screw-terminal adapter when using built-in measurement types on the NI-9218.
NI-9218 ສະຫນອງການສະຫນັບສະຫນູນເພີ່ມເຕີມສໍາລັບປະເພດການວັດແທກຕໍ່ໄປນີ້ເມື່ອໃຊ້ອະແດບເຕີສະເພາະການວັດແທກ.
- ±20 mA, requires the NI-9983
- ±60 V, requires the NI-9987
- Half-Bridge requires the NI-9986
- Quarter-Bridge requires the NI-9984 (120 Ω) or NI-9985 (350 Ω)
±16 V ການເຊື່ອມຕໍ່
NI-9218 ສະຫນອງການກະຕຸ້ນເຊັນເຊີ 12 V ທາງເລືອກ. ເພື່ອໃຊ້ການກະຕຸ້ນ 12 V, ເຊື່ອມຕໍ່ການສະຫນອງພະລັງງານ 9 VDC ກັບ 30 VDC ກັບ Vsup, ເຊື່ອມຕໍ່ຈຸດກະຕຸ້ນໃນເຊັນເຊີຂອງທ່ານກັບ EX+/EX-, ແລະເປີດໃຊ້ 12 V excitation ໃນຊອບແວຂອງທ່ານ.
ອ້າງອີງທີ່ກ່ຽວຂ້ອງ:
- NI-9982 ±16 V ການເຊື່ອມຕໍ່ Pinout
ການເຊື່ອມຕໍ່ ±65 mV
- You must connect AI to EX- on the NI-9218.
- NI-9218 ສະຫນອງການກະຕຸ້ນເຊັນເຊີ 12 V ທາງເລືອກ. ເພື່ອໃຊ້ການກະຕຸ້ນ 12 V, ເຊື່ອມຕໍ່ການສະຫນອງພະລັງງານ 9 VDC ກັບ 30 VDC ກັບ Vsup, ເຊື່ອມຕໍ່ຈຸດກະຕຸ້ນໃນເຊັນເຊີຂອງທ່ານກັບ EX+/EX-, ແລະເປີດໃຊ້ 12 V excitation ໃນຊອບແວຂອງທ່ານ.
ອ້າງອີງທີ່ກ່ຽວຂ້ອງ
- NI-9982 ±65 mV Pinout ການເຊື່ອມຕໍ່
ການເຊື່ອມຕໍ່ຂົວເຕັມ
- The NI-9218 provides 2 V excitation to loads ≥120 Ω or 3.3 V excitation to loads ≥350 Ω.
- The NI-9218 provides optional connections for remote sensing (RS) and shunt calibration (SC). Remote sensing corrects for errors in excitation leads, and shunt calibration corrects for errors caused by resistance within one leg of the bridge.
ອ້າງອີງທີ່ກ່ຽວຂ້ອງ:
- NI-9982 Full-Bridge Connection Pinout
ການເຊື່ອມຕໍ່ IEPE
- The NI-9218 provides an excitation current for each channel that powers IEPE sensors.
- AI+ provides DC excitation, and AI- provides the excitation return path.
ອ້າງອີງທີ່ກ່ຽວຂ້ອງ:
- Pinout ການເຊື່ອມຕໍ່ NI-9982 IEPE
ການເຊື່ອມຕໍ່ ±20 mA
- Connecting ±20 mA signals requires the NI-9983.
- NI-9218 ສະຫນອງການກະຕຸ້ນເຊັນເຊີ 12 V ທາງເລືອກ. ເພື່ອໃຊ້ການກະຕຸ້ນ 12 V, ເຊື່ອມຕໍ່ການສະຫນອງພະລັງງານ 9 VDC ກັບ 30 VDC ກັບ Vsup, ເຊື່ອມຕໍ່ຈຸດກະຕຸ້ນໃນເຊັນເຊີຂອງທ່ານກັບ EX+/EX-, ແລະເປີດໃຊ້ 12 V excitation ໃນຊອບແວຂອງທ່ານ.
Connecting a loop-powered 2-wire or 3-wire transducer requires adding a 20 kΩ resistor between AI- and Ex-.
ອ້າງອີງທີ່ກ່ຽວຂ້ອງ:
- NI-9983 Pinout
±60 V ການເຊື່ອມຕໍ່
Connecting ±60 V signals requires the NI-9987.
ອ້າງອີງທີ່ກ່ຽວຂ້ອງ:
- NI-9987 Pinout
ການເຊື່ອມຕໍ່ເຄິ່ງຂົວ
- Connecting half bridges requires the NI-9986.
- The NI-9218 provides 2 V excitation to half bridges of ≥240 Ω total or 3.3 V excitation to half bridges of ≥700 Ω total.
- The NI-9218 provides optional connections for remote sensing (RS) and shunt calibration (SC). Remote sensing corrects for errors in excitation leads, and shunt calibration corrects for errors caused by resistance within one leg of the bridge.
ອ້າງອີງທີ່ກ່ຽວຂ້ອງ:
- NI-9986 Pinout
ການເຊື່ອມຕໍ່ Quarter-Bridge
- Connecting 120 Ω quarter bridges requires the NI-9984.
- Connecting 350 Ω quarter bridges requires the NI-9985.
ເຄັດລັບ NI-recommends 2 V excitation when using a NI-9984 with 120 Ω quarter bridges and 3.3 V excitation when using the NI-9985 with 350 Ω quarter bridges.
ອ້າງອີງທີ່ກ່ຽວຂ້ອງ:
- NI-9984/9985 Pinout
ການເຊື່ອມຕໍ່ TEDS
For more information about TEDS, visit ni.com/info and enter the Info Code rdteds.
TEDS ສະຫນັບສະຫນູນ
- ເຊັນເຊີ TEDS Class 1 ສະຫນອງການໂຕ້ຕອບສໍາລັບການໂອນຂໍ້ມູນຈາກເຊັນເຊີ. NI-9218 ກັບ LEMO, NI-9218 ກັບ DSUB, NI-9982L, NI-9982D, NI-9982F ສະຫນັບສະຫນູນເຊັນເຊີ TEDS Class 1.
- TEDS Class 2 sensors provide an interface for transferring information from TEDS-enabled sensors. The NI-9218 with LEMO, NI-9982L, NI-9983L, NI-9984L, NI-9985L, and NI-9986L support TEDS Class 2 sensors.
Vsup Daisy Chain Topology
NI-9218 ກັບ LEMO ສະຫນອງສີ່ pins ໃນຕົວເຊື່ອມຕໍ່ Vsup ສໍາລັບສາຍໂສ້ daisy.
ຂໍ້ແນະນຳການເຊື່ອມຕໍ່ NI-9218
Make sure that the devices you connect to the NI-9218 are compatible with the module specifications.
ຂໍ້ແນະນຳສາຍເຄເບີ້ນແບບກຳນົດເອງ
- ສັງເກດເບິ່ງຄໍາແນະນໍາຕໍ່ໄປນີ້ເມື່ອໃຊ້ອະແດບເຕີຕົວເຊື່ອມຕໍ່ຈອກ solder NI-9988 ຫຼືຕົວເຊື່ອມຕໍ່ LEMO crimp (784162-01) ເພື່ອສ້າງສາຍທີ່ກໍາຫນົດເອງ.
- Use a shielded cable for all signals.
- Connect the cable shield to the earth ground.
- Use twisted-pair wiring for the AI+/AI- and RS+/RS- signals to achieve specified EMC performance.
NI-9218 Block Diagram
- Two 24-bit analogue-to-digital converters (ADCs) simultaneously sample ທັງສອງຊ່ອງທາງ AI.
- The NI-9218 provides channel-to-channel isolation.
- The NI-9218 reconfigures the signal conditioning for each measurement type.
- The NI-9218 provides excitation for IEPE and bridge completion measurement types.
- The NI-9218 can provide optional 12 V sensor excitation for ±16 V, ±65 mV, and ±20 mA measurement types.
±16 V ແລະ ±65 mV ການປັບສັນຍານ
ສັນຍານເຂົ້າໃນແຕ່ລະຊ່ອງແມ່ນ buffed, conditioned, ແລະຫຼັງຈາກນັ້ນ sampນຳພາໂດຍ ADC.
ການປັບສະພາບສັນຍານເຕັມຂົວ
- The analogue input connections sense and then amplify the incoming analogue signal.
- The excitation connections provide differential bridge-excitation voltage.
- Remote sensing continuously and automatically corrects for lead-wire induced excitation voltage loss when using the RS connections.
- Shunt calibration can be used to correct for lead-wire-induced desensitisation of the bridge.
ການປັບສະພາບສັນຍານ IEPE
- The incoming analogue signal is referenced to an isolated ground.
- Each channel is configured for AC coupling with an IEPE current.
- Each channel provides a TEDS Class 1 interface.
±20 mA ການປັບສັນຍານ
The NI-9983 provides a current shunt for the incoming analogue signal.
±60 V ການປັບສັນຍານ
The NI-9987 provides an attenuator for the incoming analogue signal.
ການປັບສະພາບສັນຍານເຄິ່ງຂົວ
- The NI-9886 provides half-bridge completion resistors for the incoming analogue signal.
- You must connect AI+, EX+, and EX-.
- RS+ and RS- connections are optional.
- You do not need to connect the AI signal because it is connected internally.
ການປັບປ່ຽນໂໝດຂົວຂ້າມສີ່
The NI-9984 and NI-9985 provide a quarter-bridge completion resistor and a half-bridge completion resistor.
ການກັ່ນຕອງ
The NI-9218 uses a combination of analogue and digital filtering to provide an accurate representation of in-band signals while rejecting out-of-band signals. The filters discriminate between signals based on the frequency range, or bandwidth, of the signal. The three important bandwidths to consider are the passband, the stopband, and the alias-free bandwidth.
NI-9218 ເປັນຕົວແທນຂອງສັນຍານພາຍໃນ passband, ຕາມການຄິດໄລ່ຕົ້ນຕໍໂດຍ passband ripple ແລະໄລຍະ nonlinearity. ສັນຍານທັງຫມົດທີ່ປາກົດຢູ່ໃນແບນວິດທີ່ບໍ່ມີນາມແຝງແມ່ນເປັນສັນຍານທີ່ບໍ່ມີນາມແຝງຫຼືສັນຍານທີ່ຖືກກັ່ນຕອງໂດຍຢ່າງຫນ້ອຍປະລິມານການປະຕິເສດແຖບຢຸດ.
Passband
ສັນຍານພາຍໃນ passband ມີການເພີ່ມ ຫຼືຫຼຸດຄວາມຖີ່ຂື້ນກັບຄວາມຖີ່. ຈໍານວນເລັກນ້ອຍຂອງການປ່ຽນແປງທີ່ເພີ່ມຂຶ້ນກ່ຽວກັບຄວາມຖີ່ແມ່ນເອີ້ນວ່າ passband flatness. ຕົວກອງດິຈິຕອນຂອງ NI-9218 ປັບລະດັບຄວາມຖີ່ຂອງ passband ໃຫ້ກົງກັບອັດຕາຂໍ້ມູນ. ດັ່ງນັ້ນ, ຈໍານວນການເພີ່ມຂຶ້ນຂອງຫຼືການຫຼຸດຫນ້ອຍລົງໃນຄວາມຖີ່ໃດຫນຶ່ງແມ່ນຂຶ້ນກັບອັດຕາຂໍ້ມູນ.
ແຖບຢຸດ
ການກັ່ນຕອງຫຼຸດລົງຢ່າງຫຼວງຫຼາຍສັນຍານທັງຫມົດຂ້າງເທິງຄວາມຖີ່ຂອງການຢຸດ. ເປົ້າຫມາຍຕົ້ນຕໍຂອງການກັ່ນຕອງແມ່ນເພື່ອປ້ອງກັນການໃສ່ນາມແຝງ. ດັ່ງນັ້ນ, ຂະຫນາດຄວາມຖີ່ stopband ຊັດເຈນກັບອັດຕາຂໍ້ມູນ. ການປະຕິເສດແຖບຢຸດແມ່ນຈໍານວນການຫຼຸດຜ່ອນຕໍາ່ສຸດທີ່ນໍາໃຊ້ໂດຍການກັ່ນຕອງກັບສັນຍານທັງຫມົດທີ່ມີຄວາມຖີ່ພາຍໃນແຖບຢຸດ.
ແບນວິດທີ່ບໍ່ມີນາມແຝງ
Any signal that appears in the alias-free bandwidth of the NI-9218 is not an aliased artefact of signals at a higher frequency. The alias-free bandwidth is defined by the ability of the filter to reject frequencies above the stopband frequency, and it is equal to the data rate minus the stopband frequency.
ການເປີດຕົວດັດແປງການວັດແທກ
ສິ່ງທີ່ຕ້ອງເຮັດ
- Unlock the measurement adapter housing/cover.
- Slide the measurement adapter housing/cover to access the screw terminals.
ການຕິດຕັ້ງ NI-998xD/998xL
ສິ່ງທີ່ຄວນໃຊ້
- NI-998xD or NI-998xL Measurement Adapter
- M4 or Number 8 Screw
- ໄຂຄວງ
ສິ່ງທີ່ຕ້ອງເຮັດ
Mount the measurement adapter to a flat surface using the mounting hole on the measurement adapter and the screw.
ການວັດແທກສາຍດິນຂອງອະແດບເຕີ
terminals ດິນໃນອະແດບເຕີການວັດແທກແມ່ນເຊື່ອມຕໍ່ກັບ chassis ground ເມື່ອອະແດບເຕີການວັດແທກເຊື່ອມຕໍ່ກັບ NI-9218 ແລະ NI-9218 ຖືກຕິດຕັ້ງຢູ່ໃນ chassis.
ການວັດແທກ Pinouts Adapter
ພາກສ່ວນຕໍ່ໄປນີ້ປະກອບມີ pinouts ສໍາລັບອະແດບເຕີການວັດແທກ NI-9218.
NI-9982 ±16 V ການເຊື່ອມຕໍ່ Pinout
Pins 3a and 3b are tied together on the NI-9982.
ອ້າງອີງທີ່ກ່ຽວຂ້ອງ:
- ±16 V ການເຊື່ອມຕໍ່
NI-9982 ±65 mV Pinout ການເຊື່ອມຕໍ່
Pins 3a and 3b are tied together on the NI-9982.
ອ້າງອີງທີ່ກ່ຽວຂ້ອງ:
- ການເຊື່ອມຕໍ່ ±65 mV
NI-9982 Full-Bridge Connection Pinout
Pins 3a and 3b are tied together on the NI-9982.
ອ້າງອີງທີ່ກ່ຽວຂ້ອງ:
- ການເຊື່ອມຕໍ່ຂົວເຕັມ
Pinout ການເຊື່ອມຕໍ່ NI-9982 IEPE
Pins 3a and 3b are tied together on the NI-9982.
ອ້າງອີງທີ່ກ່ຽວຂ້ອງ:
- ການເຊື່ອມຕໍ່ IEPE
NI-9983 Pinout
Pins 3a and 3b are tied together on the NI-9983.
ອ້າງອີງທີ່ກ່ຽວຂ້ອງ:
- ການເຊື່ອມຕໍ່ ±20 mA
NI-9984/9985 Pinout
ອ້າງອີງທີ່ກ່ຽວຂ້ອງ:
- ການເຊື່ອມຕໍ່ Quarter-Bridge
NI-9986 Pinout
Pins 3a and 3b are tied together on the NI-9986.
ອ້າງອີງທີ່ກ່ຽວຂ້ອງ:
- ການເຊື່ອມຕໍ່ເຄິ່ງຂົວ
NI-9987 Pinout
Pins 3a and 3b are tied together on the NI-9987.
ອ້າງອີງທີ່ກ່ຽວຂ້ອງ:
- ±60 V ການເຊື່ອມຕໍ່
FAQ
ເອກະສານ / ຊັບພະຍາກອນ
![]() |
National Instruments NI-9218 Channel Analog Input Module [pdf] ຄູ່ມືການສອນ NI-9218 ກັບ LEMO, NI-9218 ກັບ DSUB, NI-9218 Channel Analog Input Module, NI-9218, Channel Analog Input Module, Analog Input Module, Input Module |