ຫຼາຍເຄົາເຕີ
ເຄື່ອງຈັບເວລາ, ເຄື່ອງນັບ, ຄວາມຖີ່, Geiger
ເອກະສານຄໍາແນະນໍາ

LB4071-101
ລາຍລະອຽດ:
The IEC ‘MULTI – COUNTER’ is a compact and versatile instrument for general laboratory timing to 0.1 ms, counting, measuring frequency or rate and for performing Geiger counting.
Each of the 3x modes (Timing, Counting/Freq and Geiger) has a set of ‘Functions’ to select the type of function you want for the mode you selected. All selection is by LED and the indication reminds you always of the mode and function that is operating
ຄຸນນະສົມບັດພິເສດແມ່ນ:
- High speed timing to 100 microseconds resolution.
- Large six digit LED display.
- All press button operation with LED indication of functions.
- Automatic loading memory up to a depth of 20 values.
- Memory items can be selectively deleted to remove errors. Memory items can be scrolled, totaled or averaged.
- Sockets for extension speaker.
- Speaker and volume control for all counts and frequency.
- Out put sockets for 12V.AC. supply for photogate lamps.
- Accepts both high voltage ທໍ່ GM ແລະຕ່ໍາ voltage ເຄື່ອງກວດຈັບ Alpha. ທັງສອງສາມາດໃຊ້ໄດ້ຈາກ IEC ຕາມການຮ້ອງຂໍ.
- Start/Stop TIME sockets also operate as remote Start/Stop sockets when running in COUNT, FREQUENCY or GEIGER modes.
ຄວາມຍາວ: 375mm
ຄວາມເລິກ: 170mm
ຄວາມສູງ: 107mm
ນ້ໍາຫນັກ: 2.4kg
ຂໍ້ມູນຈໍາເພາະ:
POWER: 220/240V.AC 50/60Hz.
ຄວາມແມ່ນຍໍາ: ການດໍາເນີນງານທັງຫມົດທີ່ກ່ຽວຂ້ອງກັບເວລາແລະຄວາມຖີ່ແມ່ນຖືກລັອກໄປເຊຍກັນເພື່ອຮັບປະກັນຄວາມຖືກຕ້ອງດີກວ່າ: 0.01% +/-1 ຕົວເລກທີ່ສໍາຄັນຫນ້ອຍ.
ຫນ້າທີ່ທັງຫມົດແມ່ນ microprocessor ຄວບຄຸມ.
ການເປີດເຄື່ອງເບື້ອງຕົ້ນ:
ໜ່ວຍຕ່າງໆຖືກຕິດຕັ້ງດ້ວຍຊັອກເກັດຫຼັກ IEC 3 pin ເພື່ອຮັບເອົາສາຍໄຟຫຼັກແຍກ. ສຽບເຂົ້າໄປໃນມາດຕະຖານ 240V.AC. ປ່ຽງໄຟ. ຈໍສະແດງຜົນດິຈິຕອນຄວນສະຫວ່າງ.
- Small LEDs indicate the Mode of operation and Function.
- Press MODE button to select the Mode of operation required.
- Press FUNCTION button to select Function required in that mode.
ກົດປຸ່ມດໍາເນີນງານ:
- START: initiates timing, counting or Geiger counting.
- STOP: stops timing or counting and value is stored in memory.
- RESET: operates after STOP. Zero display and also performs an Auto Mode external connection check on START/STOP sockets.
- MEM UP/MEM DOWN scrolls and recalls active memory locations.
ໜ່ວຍຄວາມຈຳ:
When STOP occurs by either press button or by remote socket, the last value is automatically stored into memory. When any value is stored, the small ‘MEM’ LED is on. When 20 values are stored (memory full), the memory LED flashes.
MEM ຂຶ້ນ/ລົງ
Buttons scroll through the active memory store. When the first or last stored memory is reached, a longer beep sounds.
TOTAL
ປຸ່ມເພີ່ມຄ່າຄວາມຈຳທັງໝົດຮ່ວມກັນ. ກົດຄ້າງໄວ້ຈົນກວ່າຈະໄດ້ຍິນສຽງບີບສອງເທື່ອ. ທັງໝົດຂອງຄ່າຄວາມຈຳຈະສະແດງໃນຂະນະທີ່ປຸ່ມຖືກກົດຄ້າງໄວ້.
AVRG
Button calculates the average of all the memory values. Press and hold until double beep is heard.
Average will display whilst button is held depressed.
ລ້າງ
Button removes selected memory values. Scroll to select the unwanted value. Press and hold button until double beep is heard. Selection is now erased from memory leaving the other values untouched.
Display shows ‘——‘.
ອະນາໄມ
Button empties all memory values. Press and hold button until double beep is heard. Memory store will be empty and the small ‘MEM’ LED will be off.
ໂໝດ:
Three different modes of operation are selectable:
- ເວລາ
- Counting & Frequency
- Geiger counting.
ເວລາ:
ຊ່ວງອັດຕະໂນມັດ:
0.0001s up to 99.9999 seconds, then Auto Ranges to 999.999 seconds by 0.001s.
ໂໝດ ອັດຕະໂນມັດ:
ຟັງຊັນນີ້ຖືກຕັ້ງໂດຍການກົດ STOP ຈາກນັ້ນກົດປຸ່ມ RESET ຕາມລໍາດັບ. ເມື່ອຕັ້ງ, ການເລີ່ມຕົ້ນແລະການຢຸດເວລາຈະເກີດຂື້ນກັບການປ່ຽນແປງຂອງສະຖານະຂອງການເຊື່ອມຕໍ່ໄຟຟ້າຂອງ START / STOP. ຄຸນນະສົມບັດອັດຕະໂນມັດນີ້ສາມາດປະຫຍັດເວລາແລະຄວາມຫຍຸ້ງຍາກໃນຫ້ອງຮຽນໂດຍການກໍາຈັດຄວາມຈໍາເປັນຂອງການສ້າງສະເພາະ 'ເຮັດ' ຫຼື 'ທໍາລາຍ' ການເຊື່ອມຕໍ່ພາຍນອກສໍາລັບການທົດລອງ.
ມີສີ່ຫນ້າທີ່ທີ່ແຕກຕ່າງກັນຂອງເວລາ:
ເລີ່ມຕົ້ນ / ຢຸດ:
ເມື່ອສະຖານະຂອງການເຊື່ອມຕໍ່ START ຖືກປ່ຽນເປັນຊ່ວງເວລາຕົວຈັບເວລາແລ່ນ. ການເຊື່ອມຕໍ່ເລີ່ມຕົ້ນຫຼັງຈາກນັ້ນບໍ່ມີຜົນ. ເມື່ອສະຖານະຂອງການເຊື່ອມຕໍ່ STOP ຖືກປ່ຽນແປງທັນທີ, ເຄື່ອງຈັບເວລາຢຸດ ແລະໜ່ວຍຄວາມຈຳຈະຖືກໂຫລດ.
ຖ່າຍຮູບ:
ເມື່ອສະຖານະຂອງການເຊື່ອມຕໍ່ START ຖືກປ່ຽນໂມງຈັບເວລາຈະແລ່ນ. ເມື່ອຊັອກເກັດດຽວກັນກັບໄປເປັນສະຖານະເດີມ, ເຄື່ອງຈັບເວລາຢຸດແລະຄ່າຈະຖືກເກັບໄວ້ໃນຫນ່ວຍຄວາມຈໍາ. ເຕົ້າຮັບຍັງສະຫນອງພະລັງງານທີ່ຈໍາເປັນເພື່ອດໍາເນີນການວົງຈອນ photogate ສ່ວນໃຫຍ່.
ໄລຍະເວລາ:
ເມື່ອສະຖານະຂອງການເຊື່ອມຕໍ່ START ຖືກປ່ຽນໂມງຈັບເວລາຈະແລ່ນ. ເມື່ອຊັອກເກັດດຽວກັນກັບໄປເປັນສະຖານະເດີມບໍ່ມີຜົນຫຍັງເລີຍ. ເມື່ອຊັອກເກັດດຽວກັນຖືກປ່ຽນແປງອີກເທື່ອຫນຶ່ງ, ຄ່າຈະຖືກເກັບໄວ້ໃນຫນ່ວຍຄວາມຈໍາ, ໂມງຈັບເວລາຖືກຕັ້ງໃຫມ່ແລະຫຼັງຈາກນັ້ນເລີ່ມຈັບເວລາໃນໄລຍະເວລາຕໍ່ໄປ. ເພື່ອຢຸດເວລາໃຫ້ກົດ STOP.
PENDULUM:
When the status of the START connections is changed the timer runs. When same sockets revert to original status there is no effect. When same sockets are changed again, there is no effect. Upon the fourth change, the value is stored in memory, the timer is reset and then starts timing the next pendulum period. To stop timing press STOP. Effectively this is a double ‘PERIOD’.
ການນັບ & ຄວາມຖີ່:
ປຸ່ມ START ແລະ STOP ຫຼືການເຂົ້າຮ່ວມຂອງຊັອກເກັດ TIME START/STOP ອະນຸຍາດໃຫ້ການນັບ ແລະຄວາມຖີ່ຂອງການວັດແທກເລີ່ມຕົ້ນ ຫຼືຢຸດ. ເມື່ອຢຸດ, ຄ່າສຸດທ້າຍຈະຖືກເກັບໄວ້ໃນຫນ່ວຍຄວາມຈໍາ.
ການຕອບສະໜອງການປ້ອນຂໍ້ມູນ:
ສາມາດນັບໄດ້ 20mv P/P ຫາ 100V. ຄວາມອ່ອນໄຫວຂອງການນັບເຂົ້າສາມາດປັບໄດ້ລະຫວ່າງຂໍ້ຈໍາກັດເຫຼົ່ານີ້. ສໍາລັບກໍາມະຈອນໃນລະດັບຕ່ໍາ, ເພີ່ມທະວີຄວາມອ່ອນໄຫວຈົນກ່ວາການນັບສະຫມໍ່າສະເຫມີແລະເຊື່ອຖືໄດ້ເກີດຂຶ້ນ.
ມີສີ່ຫນ້າທີ່ທີ່ແຕກຕ່າງກັນຂອງການນັບແລະຄວາມຖີ່:
ຢ່າງຕໍ່ເນື່ອງ:
Counting continues until Stop button pressed or Stop sockets change in state. Value is stored automatically.
100 SEC:
ນັບເປັນເວລາ 100 ວິນາທີ. ຫຼັງຈາກເວລານີ້ຫມົດອາຍຸ, ການນັບຢຸດແລະຈໍານວນທັງຫມົດຈະສະແດງ. ຄ່າຈະຖືກເກັບໄວ້ໂດຍອັດຕະໂນມັດໃນຫນ່ວຍຄວາມຈໍາ.
10 SEC:
ນັບເປັນເວລາ 10 ວິນາທີ. ຫຼັງຈາກເວລານີ້ຫມົດອາຍຸ, ການນັບຢຸດແລະຈໍານວນທັງຫມົດຈະສະແດງ. ຄ່າຈະຖືກເກັບໄວ້ໂດຍອັດຕະໂນມັດໃນຫນ່ວຍຄວາມຈໍາ.
ຄວາມຖີ່:
The pulses applied are counted per second and displayed as frequency to a maximum of 999,999Hz.
Starting and stopping of the frequency function is performed by the buttons or the sockets in the TIME mode section. Each time the frequency is updated, the last value is automatically stored in memory.
ການນັບ Geiger:
ການຕັ້ງຄ່າຂອງ GM VOLTS ຄວນເຫມາະສົມກັບປະເພດທໍ່ທີ່ໃຊ້. ລະດັບຄວາມກວ້າງປົກກະຕິ Alpha, Beta & Gamma halogen quenched GM tube (ປະເພດ MX168 ຫຼືຄ້າຍຄືກັນ), voltage ຄວນຈະມີປະມານ 450V.DC. ສໍາລັບຄວາມຫນ້າເຊື່ອຖືທີ່ດີທີ່ສຸດແລະຄວາມອ່ອນໄຫວ.
ມີສີ່ຫນ້າທີ່ທີ່ແຕກຕ່າງກັນຂອງການນັບ Geiger:
ຢ່າງຕໍ່ເນື່ອງ:
ການນັບສືບຕໍ່ໄປຈົນກວ່າຈະກົດປຸ່ມ STOP ຫຼື STOP sockets ປ່ຽນສະຖານະ. ການນັບ Geiger ແຕ່ລະຄົນທີ່ໃຊ້ກັບເຕົ້າຮັບແມ່ນນັບ. ສະບັບເລກທີtage ນໍາໃຊ້ກັບທໍ່ GM ສາມາດປັບໄດ້ຈາກ 200 ຫາ 600 V.DC. ສໍາລັບຄວາມອ່ອນໄຫວທີ່ດີທີ່ສຸດ ແລະສໍາລັບການທົດລອງທີ່ກ່ຽວຂ້ອງກັບ 'Plateau Voltages'.
In addition to the normal high voltage ລະບົບທໍ່ GM, IEC ຜະລິດເຄື່ອງກວດຈັບອະນຸພາກຂອງລັດແຂງພິເສດ ALPHA, ມີ inbuilt amplifier, ເຊິ່ງສາມາດຖືກນໍາໃຊ້ສໍາລັບການຊອກຄົ້ນຫາອະນຸພາກ Alpha ໃນລະດັບຕ່ໍາ.
TOTAL
ນັບໃນໄລຍະ 10 ຫຼື 100 ວິນາທີ: ຫຼັງຈາກເວລານີ້ຫມົດອາຍຸ, ການນັບ Geiger ຢຸດເຊົາແລະຈໍານວນທັງຫມົດຈະຖືກສະແດງ. ຄ່າຈະຖືກເກັບໄວ້ໂດຍອັດຕະໂນມັດໃນຫນ່ວຍຄວາມຈໍາ.
ອັດຕາ:
ກຳມະຈອນທີ່ກວດພົບແມ່ນນັບຕໍ່ວິນາທີ ແລະສະແດງເປັນຄວາມຖີ່ ຫຼືອັດຕາສູງສຸດເຖິງ 999,999Hz. ການເລີ່ມຕົ້ນແລະການຢຸດຟັງຊັນຄວາມຖີ່ແມ່ນປະຕິບັດຢູ່ທີ່ປຸ່ມຫຼືເຕົ້າຮັບໃນພາກສ່ວນໂຫມດ TIME. ແຕ່ລະຄັ້ງທີ່ຟັງຊັນຖືກຢຸດ, ຄ່າສຸດທ້າຍຈະຖືກເກັບໄວ້ໃນຫນ່ວຍຄວາມຈໍາ.
ລໍາໂພງ:
The instrument has an inbuilt speaker to monitor the ‘GM clicks’ together with sockets for an extension speaker (8 ohm impedance). A speaker volume control is provided.
Lamp ຜົນຜະລິດ:
ເຕົ້າຮັບຜົນຜະລິດໃຫ້ 12V.AC. ຢູ່ທີ່ 1 amp ສໍາລັບ Photogate lamps ແລະອື່ນໆ.
ໄລຍະໄກ:
Duplicates the RESET button function. Using a long cable, this socket can be joined to the common or ‘GRND’ socket by a switch or press button to create a remote RESET control.
ອຸປະກອນເສີມທາງເລືອກ:
- Photogates for experiments.
- Geiger Muller Tube with tube holder and lead.
- Solid state ALPHA particle detector with holder and lead.
- Extension speaker, 8 ohm impedance.
ອອກແບບແລະຜະລິດຢູ່ໃນອົດສະຕາລີ
LB 4071 – 101 ( new ) no slave display. doc
ເອກະສານ / ຊັບພະຍາກອນ
![]() |
IEC LB4071-101 Multi Counter Timer [pdf] ຄູ່ມືການສອນ LB4071-101, LB4071-101 Multi Counter Timer, LB4071-101, Multi Counter Timer, Counter Timer, Timer |