Reznor UDXC-45

Reznor UDXC-45 ຄູ່ມືການສອນເຄື່ອງເຮັດຄວາມຮ້ອນຫນ່ວຍອາຍແກັສທໍາມະຊາດ

Model: UDXC-45

1. ບົດແນະນຳ

The Reznor UDXC-45 is a 45,000 BTU natural gas unit heater designed for indoor use in various spaces, including commercial, industrial, and residential garages, workshops, and warehouses. This manual provides essential information for the safe and efficient installation, operation, and maintenance of your heater. Please read all instructions thoroughly before proceeding with installation or operation.

2. ຂໍ້ມູນຄວາມປອດໄພ

ຄໍາເຕືອນ: ການຕິດຕັ້ງ, ການປັບ, ການປ່ຽນແປງ, ການບໍລິການ, ຫຼືການບໍາລຸງຮັກສາທີ່ບໍ່ເຫມາະສົມສາມາດເຮັດໃຫ້ເກີດຄວາມເສຍຫາຍຕໍ່ຊັບສິນ, ການບາດເຈັບ, ຫຼືເສຍຊີວິດ. ອ່ານ​ຄໍາ​ແນະ​ນໍາ​ການ​ຕິດ​ຕັ້ງ​, ການ​ປະ​ຕິ​ບັດ​, ແລະ​ການ​ບໍາ​ລຸງ​ຮັກ​ສາ​ຢ່າງ​ລະ​ອຽດ​ກ່ອນ​ທີ່​ຈະ​ຕິດ​ຕັ້ງ​ຫຼື​ການ​ບໍ​ລິ​ການ​ອຸ​ປະ​ກອນ​ນີ້​.

  • ການສະຫນອງອາຍແກັສ: Ensure the gas supply is turned off before any installation or maintenance. All gas connections must be leak-tested.
  • ການລະບາຍອາກາດ: Proper venting is critical to prevent carbon monoxide poisoning. Ensure the vertical Category 1 B-vent kit is installed correctly and maintained.
  • ການເຊື່ອມຕໍ່ໄຟຟ້າ: All electrical wiring must comply with local codes and be performed by a qualified electrician. Disconnect power before servicing.
  • ການອະນາໄມ: Maintain adequate clearances from combustible materials as specified in the installation instructions.
  • ການຕິດຕັ້ງແບບມືອາຊີບ: Installation and service should be performed by a qualified installer, service agency, or gas supplier.

3. ຜະລິດຕະພັນເກີນview

The Reznor UDXC-45 unit heater is engineered for durability and efficient heating. It features a robust design suitable for demanding environments.

Reznor UDXC-45 Unit Heater with key features listed

ຮູບພາບ: ທາງຫນ້າ view of the Reznor UDXC-45 unit heater highlighting standard features such as 83% AFUE efficiency and TCORE2 heat exchanger.

ຄຸນ​ນະ​ສົມ​ບັດ​ທີ່​ສໍາ​ຄັນ​:

  • ປະສິດທິພາບສູງ: Rated for 45,000 BTU with an 83% thermal efficiency rating.
  • ການກໍ່ສ້າງທົນທານ: ມີຕົວແລກປ່ຽນຄວາມຮ້ອນເຫຼັກອະລູມິນຽມທີ່ເສີມຄວາມໝັ້ນຄົງດ້ວຍທາດ titanium TCORE2.
  • Advanced Ignition: Patented single-burner combustion with multi-try direct spark ignition and time lockout.
  • ການໂຕ້ຕອບຜູ້ໃຊ້: Integrated circuit board with a 7-segment display for troubleshooting and status-indicating LED.
  • ການດໍາເນີນງານງຽບ: Low noise operation with vibration-isolated fan and venter motors.
  • ຄວາມຍືດຫຍຸ່ນການຕິດຕັ້ງ: Threaded-nut retainers at four suspension points for ceiling or wall mounting (mounting hardware sold separately).
  • ການເຂົ້າເຖິງການບໍາລຸງຮັກສາ: Hinged access door panel with a quarter-turn latch and external gas connection for ease of maintenance.
Icons representing scratch resistance, durable build, modern design, and quiet operation

Image: Visual representation of the heater's attributes including scratch resistance, durable build, modern design, and quiet operation.

4. ຂໍ້ມູນຈໍາເພາະ

Detailed technical specifications for the Reznor UDXC-45 unit heater.

Diagram showing dimensions of the 45,000 BTU Reznor heater

Image: Diagram illustrating the physical dimensions of the 45,000 BTU Reznor UDXC-45 heater.

ຂໍ້ມູນຈໍາເພາະມູນຄ່າ
ໝາຍເລກຕົວແບບUDXC-45
ຜົນຜະລິດຄວາມຮ້ອນ45,000 ໜ່ວຍຄວາມຮ້ອນຂອງອັງກິດ (BTU)
ປະສິດທິພາບຄວາມຮ້ອນ83%
ປະເພດນໍ້າມັນເຊື້ອໄຟອາຍແກັສທໍາມະຊາດ
ວິທີການເຮັດຄວາມຮ້ອນອາກາດບັງຄັບ
ການນຳໃຊ້ພາຍໃນ/ນອກພາຍໃນ
ປັດໄຈແບບຟອມເພດານ
ຂະໜາດສິນຄ້າ (ກວ້າງ x ຍາວ x ສູງ)29.75" x 27" x 13.75"
ຈໍານວນຄວາມໄວ2

5. ການຕິດຕັ້ງ

The Reznor UDXC-45 is designed for ceiling or wall mounting. A vertical Category 1 double wall B-vent kit is included for roof venting. Consult a qualified professional for installation to ensure compliance with all local codes and safety standards.

ການຕິດຕັ້ງ:

  • The unit features threaded-nut retainers at four suspension points for secure mounting.
  • Mounting hardware is sold separately and should be selected based on the specific installation environment and structural requirements.
  • Ensure the mounting location can support the weight of the unit and provides adequate clearance from combustible surfaces.
Reznor UDXC-45 heater installed on a ceiling in a garage

Image: A Reznor UDXC-45 heater mounted on a ceiling, demonstrating a typical installation in a garage or workshop setting.

ການລະບາຍອາກາດ:

The included vertical Category 1 double wall B-vent kit is essential for safely expelling combustion byproducts. Follow the kit's instructions and local codes for proper installation.

  • The kit typically includes components such as a Reznor CCI Vent Cap, Draft Hood Connector, Straight Pipes (12" and 24" lengths), Adjustable Elbows (60° and 90°), Roof Flashing, and a Storm Collar.
  • Ensure all vent connections are sealed properly to prevent leaks.
Components of a 4-inch diameter double wall B-vent kit

Image: Various components of a 4-inch diameter double wall B-vent kit, used for vertical venting applications.

6. ການດໍາເນີນງານ

Once properly installed and connected to the natural gas and electrical supplies, the Reznor UDXC-45 heater is ready for operation. This unit utilizes forced air for efficient heat distribution.

ການເປີດເຄື່ອງເຮັດຄວາມຮ້ອນ:

  1. Ensure the gas supply valve to the heater is open.
  2. ເປີດໄຟຟ້າໄປຫາຫນ່ວຍບໍລິການ.
  3. Set the thermostat to the desired temperature. The heater will initiate its ignition sequence.
  4. Observe the status-indicating LED and 7-segment display for operational status.

ການໄຫຼວຽນຂອງອາກາດ:

The low static pressure axial fan and power venting system are designed to reduce heat loss and ensure effective air circulation throughout the heated space.

Diagram illustrating air circulation patterns from a unit heater

Image: A diagram showing the air circulation patterns generated by a unit heater, indicating effective heat distribution.

7. ບໍາລຸງຮັກສາ

Regular maintenance ensures the longevity and efficient operation of your Reznor UDXC-45 heater. Always disconnect electrical power and turn off the gas supply before performing any maintenance.

  • ການກວດກາປະຈຳປີ: Have a qualified service technician inspect the heater annually, including the heat exchanger, burner, ignition system, and venting.
  • ທໍາຄວາມສະອາດ: Keep the area around the heater clean and free of obstructions. Periodically clean the fan blades and motor to prevent dust buildup.
  • ກວດ​ສອບ​ລະ​ບົບ​ລະບາຍ​ອາກາດ​: Inspect the vent system for any signs of corrosion, blockages, or leaks. Ensure the vent cap is clear.
  • ເຄື່ອງແລກປ່ຽນຄວາມຮ້ອນ: The TCORE2 titanium-stabilized aluminized steel heat exchanger is designed for durability, but should be inspected for any signs of damage or wear during annual service.

8. ການແກ້ໄຂບັນຫາ

The Reznor UDXC-45 is equipped with an integrated circuit board and a 7-segment display for diagnostics, along with a status-indicating LED to assist in troubleshooting. Refer to the specific error codes displayed on the 7-segment display for detailed guidance.

ບັນຫາທົ່ວໄປ:

  • ບໍ່ມີຄວາມຮ້ອນ: Check if the thermostat is set correctly, the gas supply is open, and the electrical power is on. Look for error codes on the display.
  • Pilot Light/Ignition Failure: The multi-try direct spark ignition system will attempt to light the burner multiple times. If it fails, an error code will be displayed. This may indicate a gas supply issue or a problem with the ignition components.
  • ສິ່ງລົບກວນທີ່ຜິດປົກກະຕິ: While designed for quiet operation, any new or unusual noises should be investigated. This could indicate a fan issue or other mechanical problem.
  • Heater Cycles On/Off Frequently: This could be due to an improperly sized unit, thermostat placement, or airflow restrictions.

ສໍາລັບບັນຫາທີ່ຍັງຄົງຄ້າງ ຫຼືບັນຫາທີ່ຊັບຊ້ອນ, ໃຫ້ຕິດຕໍ່ກັບຊ່າງບໍລິການທີ່ມີຄຸນວຸດທິ.

9. ການຮັບປະກັນແລະການສະຫນັບສະຫນູນ

For warranty information, please refer to the documentation provided with your Reznor UDXC-45 unit heater or contact the manufacturer directly. Support for this product may also be available through the seller, 1HVAC. Keep your purchase receipt and model number (UDXC-45) handy when contacting support.

ເອກະສານທີ່ກ່ຽວຂ້ອງ - UDXC-45

ກ່ອນview Reznor Ceiling Suspension Kit ຄູ່ມືການຕິດຕັ້ງສໍາລັບເຄື່ອງເຮັດຄວາມຮ້ອນຫນ່ວຍບໍລິການໄຟຟ້າແລະອາຍແກັສ
ຄຳແນະນຳໃນການຕິດຕັ້ງ ແລະ ລາຍລະອຽດຂອງສ່ວນປະກອບສຳລັບຊຸດຕິດຕັ້ງເພດານ Reznor CK22, ເຂົ້າກັນໄດ້ກັບເຄື່ອງເຮັດຄວາມຮ້ອນໄຟຟ້າ EHU ແລະ ເຄື່ອງເຮັດຄວາມຮ້ອນທີ່ໃຊ້ແກັສ UDXC, UDX, UDZ. ຮຽນຮູ້ວິທີການຕິດຕັ້ງເຄື່ອງເຮັດຄວາມຮ້ອນ Reznor ຂອງທ່ານຢ່າງປອດໄພ.
ກ່ອນview ການຕິດຕັ້ງຊຸດແປງອາຍແກັສ Reznor ສໍາລັບເຄື່ອງເຮັດຄວາມຮ້ອນຫົວຫນ່ວຍທີ່ມີອາຍແກັສ
ເອກະສານນີ້ໃຫ້ຄໍາແນະນໍາການຕິດຕັ້ງສໍາລັບຊຸດແປງອາຍແກັສ Reznor ສໍາລັບເຄື່ອງເຮັດຄວາມຮ້ອນຫົວຫນ່ວຍທີ່ມີອາຍແກັສຕ່າງໆ, ລວມທັງ UBX, UBXC, UBZ, UDX, UDXC, UDZ, UDAP, UDAS, UDBP, ແລະ UDBS. ມັນລາຍລະອຽດການຄັດເລືອກອົງປະກອບ, ລະມັດລະວັງຄວາມປອດໄພ, ແລະຂັ້ນຕອນການຕິດຕັ້ງສໍາລັບການປ່ຽນລະຫວ່າງອາຍແກັສທໍາມະຊາດແລະ propane, ເຊັ່ນດຽວກັນກັບການຕິດຕັ້ງສູງ.
ກ່ອນview ການຕິດຕັ້ງຊຸດລະງັບເພດານ Reznor ສໍາລັບເຄື່ອງເຮັດຄວາມຮ້ອນດ້ວຍໄຟຟ້າ ແລະນໍ້າມັນເຊື້ອໄຟ (ທາງເລືອກ CK22)
ຄູ່ມືການຕິດຕັ້ງສຳລັບຊຸດຕິດຕັ້ງເພດານ Reznor CK22, ອອກແບບມາສຳລັບເຄື່ອງເຮັດຄວາມຮ້ອນໄຟຟ້າ ແລະ ເຄື່ອງເຮັດຄວາມຮ້ອນທີ່ໃຊ້ແກັສ EHU, UDX, UDXC, ແລະ UDZ. ລວມມີອຸປະກອນຂອງຊຸດ ແລະ ຂັ້ນຕອນການຕິດຕັ້ງ.
ກ່ອນview ຄໍາແນະນໍາການລະບາຍຄວາມຮ້ອນຂອງຫນ່ວຍ Reznor ສໍາລັບແບບ UBX ແລະ UDX
Comprehensive venting instructions for Reznor UBX (Standard Power Vent Blower Type) and UDX (Standard Power Vent Fan Type) unit heaters. Covers general information, safety precautions, venting requirements, condensation mitigation, vent terminal specifications, and installation procedures for both commercial/industrial and residential applications.
ກ່ອນview Reznor Vertical Louver Kit ຄູ່ມືການຕິດຕັ້ງສໍາລັບເຄື່ອງເຮັດຄວາມຮ້ອນຫົວຫນ່ວຍທີ່ມີອາຍແກັສ (OPT-CD1)
ຄໍາແນະນໍາການຕິດຕັ້ງສໍາລັບຊຸດ Louver Reznor OPT-CD1 Vertical, ອອກແບບສໍາລັບເຄື່ອງເຮັດຄວາມຮ້ອນຂອງຫນ່ວຍງານທີ່ມີອາຍແກັສ (ແບບ UBX, UBXC, UBZ, UDX, UDXC, UDZ, UEZ). ປະກອບມີບັນຊີລາຍຊື່ອົງປະກອບແລະຄູ່ມືການປະກອບຂັ້ນຕອນໂດຍຂັ້ນຕອນ.
ກ່ອນview ຄູ່ມືການຕິດຕັ້ງຊຸດ Reznor ສໍາລັບການຄວບຄຸມຫຼາຍຫນ່ວຍ (CL31/CL32)
ຄູ່ມືການຕິດຕັ້ງທີ່ສົມບູນແບບສໍາລັບຊຸດ Relay Reznor CL31 ແລະ CL32, ເຮັດໃຫ້ການຄວບຄຸມຫຼາຍຫນ່ວຍສໍາລັບເຄື່ອງເຮັດຄວາມຮ້ອນໄຟຟ້າແລະອາຍແກັສ Reznor ຕ່າງໆ. ລວມມີລາຍການອົງປະກອບ, ຂັ້ນຕອນການຕິດຕັ້ງລະອຽດ, ແລະຂໍ້ກໍາຫນົດສາຍໄຟ.