GODIYMODULES XYWJ01-001

GODIYMODULES DC 6-30V Timer Switch LED Digital Time Delay Relay Module (Model XYWJ01-001) User Manual

Model: XYWJ01-001 | Brand: GODIYMODULES

ແນະນຳ

This manual provides detailed instructions for the installation, operation, and programming of the GODIYMODULES DC 6-30V Timer Switch LED Digital Time Delay Relay Module, Model XYWJ01-001. Please read this manual thoroughly before use to ensure proper functionality and safety.

GODIYMODULES DC 6-30V Timer Switch LED Digital Time Delay Relay Module, front view

ຮູບ 1: ດ້ານຫນ້າ view of the DC 6-30V Timer Switch LED Digital Time Delay Relay Module.

ຂໍ້ມູນຄວາມປອດໄພ

ປະຕິບັດຕາມຄວາມລະມັດລະວັງດ້ານຄວາມປອດໄພຕໍ່ໄປນີ້ສະເໝີ:

  • ຮັບປະກັນການສະຫນອງພະລັງງານ voltage is within the specified range of 6V to 30V DC.
  • ຕັດການເຊື່ອມຕໍ່ໄຟຟ້າກ່ອນທີ່ຈະເຮັດການເຊື່ອມຕໍ່ຫຼືປັບສາຍໄຟ.
  • ຫຼີກລ່ຽງການໃຫ້ໂມດູນຖືກຄວາມຊຸ່ມຊື່ນ, ອຸນຫະພູມທີ່ຮຸນແຮງ, ຫຼື ສະພາບແວດລ້ອມທີ່ກັດກ່ອນ.
  • Do not attempt to disassemble or modify the module beyond the instructions provided.
  • ການຕິດຕັ້ງຄວນໄດ້ຮັບການປະຕິບັດໂດຍບຸກຄະລາກອນທີ່ມີຄຸນວຸດທິຖ້າທ່ານບໍ່ແນ່ໃຈກ່ຽວກັບສາຍໄຟຟ້າ.

ການຕິດຕັ້ງ ແລະ ສາຍໄຟ

The module requires a DC power supply between 6V and 30V. It features a terminal block for power input and relay output connections.

ການເຊື່ອມຕໍ່ຢູ່ປາຍຍອດ

ຫລັງ view of the timer module showing terminal block

ຮູບ 2: ດ້ານຫລັງ view showing the terminal block for power and relay connections.

The terminal block typically includes connections for:

  • V+: Positive power input (DC 6-30V)
  • V-: ພະລັງງານໄຟຟ້າລົບ (ຕໍ່ພື້ນດິນ)
  • L1: Relay Normally Open (NO) contact
  • L2: Relay Common (COM) contact
  • L3: Relay Normally Closed (NC) contact (if applicable, check module markings)

Refer to the markings on your specific module for exact terminal identification.

DC 6.0~30V Wiring Mode

Wiring diagram for DC 6-30V power supply and load

Figure 3: Wiring diagram for connecting the module to a DC 6-30V power supply and a DC load.

For DC loads, connect the positive terminal of your DC power supply to V+ and the negative terminal to V-. The load should be connected in series with the relay's common (COM) and normally open (NO) contacts, or normally closed (NC) depending on desired operation.

220V Wiring Mode (AC Load)

Wiring diagram for 220V AC load with DC 6-30V power supply

Figure 4: Wiring diagram for connecting the module to a DC 6-30V power supply and an AC 220V load.

ຄຳເຕືອນ: When connecting AC loads, extreme caution must be exercised. Ensure all power is disconnected before wiring. AC wiring should only be performed by individuals with appropriate electrical knowledge and safety training.

For AC loads, the module itself is powered by DC 6-30V. The relay contacts then switch the AC 220V circuit. Connect the AC 220V live (fire) line to the relay's common (COM) contact, and the normally open (NO) contact to one side of your AC load. The other side of the AC load connects to the AC neutral (zero) line.

Trigger Input and Serial Communication

Diagram showing trigger input, relay output, and UART access

Figure 5: Trigger input connections, relay output, and location of UART port.

The module supports high and low-level trigger inputs. Connect your trigger signal to the designated trigger input pin (refer to module markings or the diagram above). The signal ground (GND) should be common with the module's power ground.

For UART communication, the port is located behind the back cover. Carefully remove the back cover to access the UART pins. The default UART settings are 9600 baud, 8 data bits, 1 stop bit (9600,8,1).

UART Commands:

  • ອ່ານ: Read system parameters
  • OP:xxxx: Set ON time (e.g., OP:1s, OP:0.1s, OP:0.01s, OP:1min)
  • CL:xxxx: Set OFF time (e.g., CL:1s, CL:0.1s, CL:0.01s, CL:1min)
  • LP:xxxx: Set loop cycles
  • ເລີ່ມ: Trigger/Start (P0-P7 Active)
  • ຢຸດ: Pause (P0-P7 Active)
  • PX: Set the working mode (P0-P9)

ຄໍາແນະນໍາການດໍາເນີນງານ

The module features an LCD display and several buttons for operation and programming.

Button Functions and Display

Labeled diagram of the timer module's buttons and LCD display

Figure 6: Front panel with labeled buttons and display elements.

  • Setting Button (Gear icon): Used to enter and navigate programming modes.
  • Add Button (Up arrow): Increases parameter values.
  • Reduce Button (Down arrow): Decreases parameter values.
  • Pause/Trigger Button (Power icon): Pauses/resumes timing or acts as a manual trigger.
  • ຈໍ LCD: Shows current working mode (e.g., P0.0P), timing status, and time values. "OUT" indicates the relay is closed.

Programming Modes (P0-P9)

The module supports various operating modes, typically designated as P0.0 to P9.9. To enter programming mode, press and hold the ປຸ່ມຕັ້ງ. ໃຊ້ ເພີ່ມ ແລະ ຫຼຸດຜ່ອນ buttons to select the desired mode. Press the ປຸ່ມຕັ້ງ again to confirm and enter parameter settings for that mode. Use ເພີ່ມ ແລະ ຫຼຸດຜ່ອນ to adjust values (OP, CL, LP) and the Pause/Trigger Button to switch between time units (seconds, minutes, hours).

Common Modes (Example):

  • P0.0: Timer ON (OP) then OFF (CL) once.
  • P1.0: Timer ON (OP) then OFF (CL) in a loop (LP cycles).
  • P2.0: Trigger ON (OP) then OFF (CL) once.
  • P3.0: Trigger ON (OP) then OFF (CL) in a loop (LP cycles).
  • (Specific mode details may vary; refer to the module's on-screen prompts or detailed documentation for your exact firmware version.)

After setting parameters, press and hold the ປຸ່ມຕັ້ງ ເພື່ອບັນທຶກ ແລະອອກຈາກໂໝດການຂຽນໂປຣແກຣມ.

ລັດພະລັງງານຕໍ່າ

If no operation is performed for 5 minutes, the module will enter a low-power state. Any button press will wake it up.

ບໍາລຸງຮັກສາ

The GODIYMODULES Timer Switch is designed for low maintenance. To ensure optimal performance:

  • ຮັກສາໂມດູນໃຫ້ສະອາດ ແລະ ບໍ່ມີຝຸ່ນ ແລະ ສິ່ງເສດເຫຼືອ. ໃຊ້ຜ້າອ່ອນ ແລະ ແຫ້ງເພື່ອທຳຄວາມສະອາດ.
  • ກວດສອບການເຊື່ອມຕໍ່ສາຍໄຟເປັນໄລຍະເພື່ອຮັບປະກັນວ່າພວກມັນປອດໄພ.
  • Avoid exposing the module to direct sunlight or excessive heat, which can degrade electronic components.

ການແກ້ໄຂບັນຫາ

If you encounter issues with your timer module, refer to the following common problems and solutions:

ບັນຫາສາເຫດທີ່ເປັນໄປໄດ້ການແກ້ໄຂ
ໂມດູນບໍ່ເປີດ.ການສະຫນອງພະລັງງານບໍ່ຖືກຕ້ອງ voltage or polarity; loose wiring.Verify power supply is 6-30V DC and connected correctly (V+ to positive, V- to negative). Check all wiring connections.
ຣີເລບໍ່ເຮັດວຽກ.Incorrect programming mode; load wiring issue; trigger not detected.Check the selected programming mode and parameters (OP, CL). Ensure the load is correctly wired to the relay contacts. If using a trigger, verify the trigger signal is correct and connected properly.
Display shows unexpected characters or behavior.Power fluctuations; internal error.Disconnect power for a few seconds, then reconnect. If the issue persists, contact support.
Difficulty programming the module.Unfamiliarity with button sequence or mode logic.Carefully re-read the "Operating Instructions" section, especially "Programming Modes." Practice the button sequences. Consider using UART for programming if comfortable.

ຂໍ້ມູນຈໍາເພາະ

  • ຕົວແບບ: XYWJ01-001
  • ການສະຫນອງພະລັງງານ: DC 6V ~ 30V
  • ຈໍສະແດງຜົນ: LCD with two columns
  • ໂໝດ Trigger: High level, Low level, Switch quantity
  • UART Communication: ແມ່ນແລ້ວ (9600,8,1)
  • ໂໝດພະລັງງານຕ່ຳ: Automatic entry after 5 minutes of inactivity
  • ຂະໜາດຜະລິດຕະພັນ: 2.24 x 1.17 x 0.8 ນິ້ວ (56.9 x 29.7 x 20.3 ມມ)
  • ນ້ໍາຫນັກລາຍການ: 1.76 ອອນສ໌ (50 ກຣາມ)
  • ຜູ້ຜະລິດ: GODIYMODULES

ການຮັບປະກັນແລະການສະຫນັບສະຫນູນ

For warranty information or technical support, please contact your retailer or the manufacturer, GODIYMODULES. Keep your purchase receipt as proof of purchase.

Manufacturer: GODIYMODULES

Model: XYWJ01-001

ເອກະສານທີ່ກ່ຽວຂ້ອງ - XYWJ01-001

ກ່ອນview ຄູ່ມືແກ້ໄຂບັນຫາສໍາລັບການຈັບເວລານ້ໍາ HiOazo
ຄູ່ມືການແກ້ໄຂບັນຫາທີ່ສົມບູນແບບສໍາລັບ HiOazo 4 Zones Water Timer, ກວມເອົາບັນຫາທົ່ວໄປເຊັ່ນ: ຄວາມຫນາແຫນ້ນໃນຫນ້າຈໍ, ຄວາມກົດດັນນ້ໍາຕ່ໍາ, ຈັບເວລາເຮັດວຽກຜິດປົກກະຕິ, ແລະການຮົ່ວໄຫລ, ມີວິທີແກ້ໄຂສໍາລັບແຕ່ລະບັນຫາ.
ກ່ອນview μBEEP ຄູ່ມືຜູ້ໃຊ້ - ລະບົບກໍານົດເວລາ Microgate
ຄູ່​ມື​ການ​ນໍາ​ໃຊ້​ທີ່​ສົມ​ບູນ​ແບບ​ສໍາ​ລັບ​ອຸ​ປະ​ກອນ Microgate μBEEP​, ລາຍ​ລະ​ອຽດ​ຫນ້າ​ທີ່​ຂອງ​ຕົນ​, ທິ​ບາຍ​ຮູບ​ແບບ​, ການ​ເຊື່ອມ​ຕໍ່​, ແລະ​ການ​ດໍາ​ເນີນ​ງານ​ສໍາ​ລັບ​ຄໍາ​ຮ້ອງ​ສະ​ຫມັກ​ກໍາ​ນົດ​ເວ​ລາ​ກິ​ລາ​. ຮຽນ​ຮູ້​ວິ​ທີ​ການ​ຕັ້ງ​ຄ່າ​ແລະ​ການ​ນໍາ​ໃຊ້ μBEEP ສໍາ​ລັບ​ການ​ກິ​ລາ​ຕ່າງໆ​ເຊັ່ນ​: ສະ​ກີ​ແລະ​ການ​ແຂ່ງ​ຂັນ​.
ກ່ອນview CRF-300 Relay Control Module Installation and Maintenance Instructions
Detailed installation and maintenance guide for the Fire-Lite Alarms CRF-300 Relay Control Module, including specifications, wiring diagrams, and operational details for addressable fire alarm systems.
ກ່ອນview Casio Module 3247 Watch ຄູ່ມືຜູ້ໃຊ້
Comprehensive user manual for the Casio Module No. 3247 wristwatch, covering timekeeping, world time, stopwatch, timer, alarm functions, water resistance, care, and specifications.
ກ່ອນview Microgate µSEM User Manual - Start Signal Light Unit
Comprehensive user manual for the Microgate µSEM start signal light unit, detailing its features, manual and cable operation, power sources, battery recharge, and mounting instructions.
ກ່ອນview ຂໍ້ມູນສະເພາະດ້ານເຕັກນິກຂອງລະບົບລຳໂພງມືອາຊີບ JBL VLA601
ລາຍລະອຽດທາງເທັກນິກ, ລາຍຊື່ອົງປະກອບ, ແລະແຜນວາດສາຍໄຟສຳລັບລະບົບລຳໂພງມືອາຊີບ JBL VLA601. ລວມທັງຂໍ້ມູນດ້ານສຽງ, ໄຟຟ້າ, ແລະທາງກາຍະພາບ.