1. ບົດແນະນຳ
Thank you for choosing the MAXSafes Model 10002V Drop Down Biometric Handgun Safe. This safe is designed to provide secure storage and quick access to your firearm using advanced finger vein recognition, a digital keypad, or a mechanical key. Please read this manual thoroughly before installation and operation to ensure proper use and maximum security.

Figure 1: MAXSafes Model 10002V Drop Down Biometric Handgun Safe
2. ຂໍ້ມູນຄວາມປອດໄພ
ຄຳເຕືອນ: Always store firearms unloaded and separate from ammunition. Keep the safe locked and out of reach of children and unauthorized individuals. Never store the mechanical override keys inside the safe. Familiarize yourself with all local and federal laws regarding firearm storage.
- ຮັບປະກັນວ່າມີການຕິດຕັ້ງຢ່າງປອດໄພເພື່ອປ້ອງກັນການໂຍກຍ້າຍອອກໂດຍບໍ່ໄດ້ຮັບອະນຸຍາດ.
- Do not leave the safe open or unattended.
- Test all access methods periodically to ensure proper function.
- ປ່ຽນແບັດເຕີລີທັນທີເມື່ອຕົວຊີ້ບອກແບັດເຕີຣີຕໍ່າປະກົດຂຶ້ນ.
3. ເນື້ອໃນຊຸດ
ກວດສອບວ່າລາຍການທັງຫມົດແມ່ນມີຢູ່ໃນຊຸດ:
- MAXSafes Model 10002V Handgun Safe
- Mechanical Override Keys (2)
- ຮາດແວຕິດຕັ້ງ (ສະກູ, ສະມໍ)
- ຄູ່ມືແນະ ນຳ (ເອກະສານນີ້)
4. ຜະລິດຕະພັນເກີນview
The MAXSafes 10002V features a robust design with multiple access options for enhanced security and convenience.

Figure 2: Key Features of the MAXSafes 10002V
ອົງປະກອບ:
- Finger Vein Scanner: For advanced biometric access.
- ປຸ່ມກົດດິຈິຕອນ: For 4-6 digit combination code entry.
- ຮູກະແຈ: For mechanical override key access.
- ຊ່ອງໃສ່ຫມໍ້ໄຟ: Located on the underside or rear of the unit.
- ໄຟ LED ພາຍໃນ: Illuminates the safe's interior upon opening.
- ຈຸດເຊື່ອມຕໍ່: For securing the safe to a wall or desk.

Figure 3: Access Methods - Vein Recognition, Digital Keypad, Mechanical Key
5. ຕັ້ງຄ່າ
5.1 ການຕິດຕັ້ງຫມໍ້ໄຟ
- Locate the battery compartment, typically on the underside or rear of the safe.
- ເປີດຝາປິດ.
- ໃສ່ແບັດເຕີຣີ AA 4 ກ້ອນ (ບໍ່ລວມ), ຮັບປະກັນວ່າຂົ້ວທີ່ຖືກຕ້ອງ (+/-).
- ປິດຝາປິດຊ່ອງໃສ່ຫມໍ້ໄຟຢ່າງປອດໄພ.
- The safe will emit a beep, indicating successful power-up.
5.2 Initial Access and Programming
Upon first use, access the safe using the mechanical override key.
- Insert the mechanical key into the keyhole and turn it to unlock the safe.
- ເປີດປະຕູທີ່ປອດໄພ.
5.2.1 Setting a Digital Combination Code
- With the safe door open, locate the internal programming button (usually a small red or green button).
- Press the programming button. The indicator light on the keypad will illuminate.
- ໃສ່ລະຫັດ 4-6 ຕົວເລກທີ່ທ່ານຕ້ອງການໃສ່ເທິງປຸ່ມກົດ.
- Press the programming button again to confirm. The safe will beep to confirm the new code.
- ທົດສອບລະຫັດໃຫມ່ດ້ວຍການເປີດປະຕູກ່ອນທີ່ຈະປິດມັນ.
5.2.2 Registering Finger Vein IDs
The safe can store up to 50 finger vein IDs.
- With the safe door open, press the programming button. The indicator light will illuminate.
- Place your finger firmly on the vein scanner. The scanner will light up and beep.
- Lift and reposition your finger slightly, then place it on the scanner again. Repeat this process 3-5 times from different angles to ensure a comprehensive scan.
- A successful registration will be indicated by a series of beeps.
- Repeat for additional fingers or users (up to 50).
- Test registered finger veins with the door open before closing it.

Figure 4: Finger Vein Recognition Technology
5.3 ການຕິດຕັ້ງຕູ້ເຊັບ
The safe can be mounted to a wall or desk. Choose a secure location that is out of sight and reach of unauthorized persons.
- Select a suitable mounting location (e.g., under a desk, inside a cabinet, on a wall stud).
- Position the safe in the desired location and mark the mounting points through the pre-drilled holes on the safe's back or bottom.
- Drill pilot holes into the mounting surface using an appropriate drill bit size for the provided hardware.
- Align the safe with the drilled holes and secure it using the provided screws and anchors. Ensure the safe is firmly attached and does not wobble.

ຮູບທີ 5: ຕົວຢ່າງamples of Wall and Desk Mounting Options
6. ຄໍາແນະນໍາການດໍາເນີນງານ
6.1 Opening with Finger Vein Recognition
- Place a registered finger firmly on the vein scanner.
- The scanner will light up, and the safe will emit a confirmation beep if the vein pattern is recognized.
- The safe door will automatically drop down, providing quick access.
6.2 Opening with Digital Keypad
- Enter your programmed 4-6 digit combination code on the keypad.
- The safe will emit a confirmation beep if the code is correct.
- The safe door will automatically drop down.
6.3 Opening with Mechanical Key
Use the mechanical key as a backup in case of battery failure or forgotten codes.
- Locate the keyhole cover (if present) and remove it.
- Insert the mechanical key into the keyhole and turn it to unlock the safe.
- The safe door will open.
6.4 ໂໝດງຽບ
The safe features a silent mode for discreet access. Refer to the safe's specific button layout for activating/deactivating silent mode (often a dedicated button or a combination press).
6.5 ໂມດປຸກ
The safe is equipped with an audible alarm. This alarm may activate if multiple incorrect access attempts are made or if the safe is tampered with. Consult the safe's interface for specific alarm settings or deactivation procedures.
6.6 ໄຟ LED ພາຍໃນ
The interior LED light automatically illuminates when the safe door opens, providing visibility in low-light conditions.
7. ບໍາລຸງຮັກສາ
7.1 ການທົດແທນຫມໍ້ໄຟ
When the low battery indicator (usually a flashing light or specific beep pattern) appears, replace all 4 AA batteries promptly. Use high-quality alkaline batteries for optimal performance.
7.2 ການທໍາຄວາມສະອາດ
ເຊັດດ້ານນອກຂອງຕູ້ນິລະໄພດ້ວຍຜ້າອ່ອນ, ງamp cloth. Avoid using abrasive cleaners or solvents that could damage the finish or electronic components. Keep the finger vein scanner clean and free of debris.
7.3 Regular Function Check
Periodically test all access methods (finger vein, keypad, mechanical key) to ensure they are functioning correctly. This helps identify potential issues before they become critical.
8. ການແກ້ໄຂບັນຫາ
If you encounter issues with your MAXSafes 10002V, refer to the following common problems and solutions:
| ບັນຫາ | ສາເຫດທີ່ເປັນໄປໄດ້ | ການແກ້ໄຂ |
|---|---|---|
| Finger vein not recognized | Improper finger placement, unregistered finger, dirty scanner, skin conditions (e.g., very dry, damaged). | Ensure firm and consistent finger placement. Re-register the finger, trying different angles. Clean the scanner. Try another registered finger or access method. |
| ປຸ່ມກົດບໍ່ຕອບສະໜອງ | Low batteries, incorrect code, keypad malfunction. | Replace batteries. Re-enter code carefully. Use mechanical key if necessary. |
| ປອດໄພບໍ່ເປີດ | Low batteries, incorrect access, mechanical obstruction. | Replace batteries. Try all access methods. Check for any obstructions preventing the door from dropping. |
| ຕົວຊີ້ວັດແບັດເຕີຣີຕໍ່າ | ແບັດເຕີຣີເຫຼືອໜ້ອຍ. | ປ່ຽນແບັດເຕີຣີ AA ທັງ 4 ໜ່ວຍທັນທີ. |
9. ຂໍ້ມູນຈໍາເພາະ
Detailed specifications for the MAXSafes Model 10002V:
- ຍີ່ຫໍ້: MAX ປອດໄພ
- ໝາຍເລກຕົວແບບ: 10002V
- ຂະໜາດຜະລິດຕະພັນ: 11.1"D x 3.8"W x 13.8"H
- ນ້ໍາຫນັກລາຍການ: 9.55 ປອນ
- ປະເພດລັອກ: Biometric (Finger Vein), Electronic Combination Lock, Key
- ສີ: ດຳ
- ຄວາມອາດສາມາດ: 8.7 ປອນ
- ວັດສະດຸ: Carbon Steel (16 gauge)
- ຄຸນນະສົມບັດພິເສດ: Sensor Light, Audible Alarm
- ປະເພດການຕິດຕັ້ງ: Wall Mount, Desk Mount
- UPC: 762736839353

Figure 6: Product Dimensions and Included Keys
10. ການຮັບປະກັນແລະການສະຫນັບສະຫນູນ
MAXSafes products are manufactured to high-quality standards. For warranty information or technical support, please refer to the contact details provided with your purchase documentation or visit the official MAXSafes webເວັບໄຊ. ຮັກສາໃບຮັບເງິນການຊື້ຂອງທ່ານໄວ້ເປັນຫຼັກຖານການຊື້ສໍາລັບການຮຽກຮ້ອງການຮັບປະກັນໃດໆ.