Fieldpiece VC1G

Fieldpiece VC1G Valve Core Remover Instruction Manual

Model: VC1G | Brand: Fieldpiece

1. ບົດແນະນຳ

The Fieldpiece VC1G Valve Core Remover is a specialized tool designed for HVACR professionals to efficiently remove and insert valve cores in refrigeration and air conditioning systems. This manual provides essential information for the safe and effective use, maintenance, and troubleshooting of your VC1G Valve Core Remover.

2. ຂໍ້ມູນຄວາມປອດໄພ

Always prioritize safety when working with refrigeration systems. Failure to follow these safety guidelines may result in injury or damage to equipment.

  • ໃສ່ອຸປະກອນປ້ອງກັນສ່ວນບຸກຄົນ (PPE): Always wear safety glasses, gloves, and appropriate clothing to protect against refrigerant exposure and mechanical hazards.
  • ລະບົບ Depressurize: Ensure the system is properly depressurized or isolated before attempting to remove or insert a valve core.
  • Handle Refrigerants Safely: Be aware of the type of refrigerant in the system and follow all applicable safety data sheet (SDS) guidelines.
  • Avoid Cross-Contamination: Use dedicated tools for different refrigerants to prevent cross-contamination.
  • ກວດ​ສອບ​ເຄື່ອງ​ມື​ກ່ອນ​ການ​ນໍາ​ໃຊ້​: Check the valve core remover for any damage, wear, or debris before each use. Ensure all connections are clean and secure.
  • ການກໍາຈັດທີ່ຖືກຕ້ອງ: Dispose of recovered refrigerants and any contaminated materials according to local regulations.

3. ຄຸນລັກສະນະຂອງຜະລິດຕະພັນ

The Fieldpiece VC1G Valve Core Remover is engineered with features to enhance efficiency and safety during HVACR service.

Fieldpiece VC1G Valve Core Remover highlighting its key features

Image: Fieldpiece VC1G Valve Core Remover highlighting its key features.

  • Swappable Service Port Fitting: Easily swap 1/4" standard service port fitting with an optional 5/16" fitting for mini-splits, offering versatility.
  • Integrated Sight Glass: Visually verify the valve core is engaged and refrigerant is flowing before removal, ensuring controlled operation.
  • ຫມວກແມ່ເຫຼັກ: Allows for easy and secure placement of the valve core set during service, preventing loss.
  • Vacuum-Rated: Rated to 20 microns, ensuring deep vacuum capabilities.
  • A2L Compatible: Designed for compatibility with A2L refrigerants.
Table comparing features of VC1, VC1G, and VC2G valve core removers

Image: Feature comparison table for Fieldpiece valve core removers, including VC1G.

Additional Features (VC1G Specific):

  • Valve Core Capture Gasket: Ensures secure capture of the valve core.
  • Free Spinning, Comfort Cap: Designed for ease of use and comfort during operation.
  • Dual Ball Valves: Provides enhanced control over refrigerant flow.

4. ຕັ້ງຄ່າ

Before operating the Fieldpiece VC1G Valve Core Remover, ensure proper setup to guarantee safe and effective use.

  1. ກວດສອບເຄື່ອງມື: Verify that the valve core remover is clean and free from any damage or debris. Check the integrity of all seals and connections.
  2. Select Correct Fitting: The VC1G comes with a 1/4" standard service port fitting. If working with mini-split systems, ensure you have the optional 5/16" fitting available and swap it if necessary.
  3. ການ​ກະ​ກຽມ​ລະ​ບົບ​: Ensure the HVACR system is in a safe state for service. This may involve isolating the section of the system you are working on and verifying pressure levels.
  4. Attach to Service Port: Securely thread the valve core remover onto the system's service port. Ensure a tight, leak-free connection.

Video: Demonstrates the setup and use of a valve core removal tool, including attaching it to a system and preparing for core removal.

Video: Illustrates the process of using an HVAC valve core removal tool, showing connection and initial steps.

5. ຄໍາແນະນໍາການດໍາເນີນງານ

Follow these steps for safe and effective removal and insertion of valve cores using the Fieldpiece VC1G.

5.1. Removing a Valve Core

  1. Connect to Service Port: Ensure the VC1G is securely attached to the system's service port.
  2. Retract Core Tool: Fully retract the internal core removal tool by turning the knurled knob counter-clockwise until it stops.
  3. Open Ball Valve: Open the ball valve on the VC1G to allow system pressure into the tool.
  4. Engage Valve Core: Slowly turn the knurled knob clockwise to extend the core removal tool. You will feel it engage with the valve core. Continue turning until the core is fully seated in the tool.
  5. Close Ball Valve: Close the ball valve to isolate the system pressure from the core removal tool.
  6. Remove Core: ສືບຕໍ່ຫັນ kn ໄດ້urled knob clockwise to extract the valve core from the system. The integrated sight glass allows you to visually confirm the core's removal and the cessation of refrigerant flow.
  7. Vent Pressure: Use the side port to vent any trapped refrigerant pressure from the tool before fully detaching the core removal tool.
  8. Retrieve Core: Once pressure is safely vented, fully unscrew the knurled knob and retrieve the valve core. Use the magnetic cap for temporary storage.

5.2. Inserting a Valve Core

  1. Load Core: Place the new valve core onto the tip of the internal core insertion tool.
  2. ເຄື່ອງມືໃສ່: Insert the core insertion tool into the VC1G and thread it clockwise until the core is positioned just before the ball valve.
  3. Open Ball Valve: Open the ball valve to equalize pressure.
  4. Seat Core: Slowly turn the knurled knob clockwise to push the valve core into its seat in the service port. Ensure it is fully tightened to prevent leaks.
  5. Retract Tool: ຫັນ kn ໄດ້urled knob counter-clockwise to retract the core insertion tool.
  6. Close Ball Valve: ປິດວາວບານ.
  7. ຕັດການເຊື່ອມຕໍ່: Carefully disconnect the VC1G from the service port.

Video: Demonstrates the operation of an HVAC valve core removal tool, showing the core removal and insertion process.

Video: Shows a leakage test for a valve core, which is crucial after insertion to ensure system integrity.

6. ບໍາລຸງຮັກສາ

Regular maintenance ensures the longevity and reliable performance of your Fieldpiece VC1G Valve Core Remover.

  • ທໍາຄວາມສະອາດ: After each use, clean the tool thoroughly to remove any refrigerant oils or debris. Use a clean cloth and appropriate cleaning agents.
  • ການລະບາຍສີ: Periodically apply a small amount of refrigeration-grade lubricant to the internal moving parts and O-rings to ensure smooth operation and prevent wear.
  • ການກວດກາປະທັບຕາ: Regularly inspect all O-rings and seals for signs of wear, cracking, or damage. Replace them immediately if any issues are found to prevent leaks.
  • ການເກັບຮັກສາ: Store the valve core remover in a clean, dry place, protected from extreme temperatures and physical damage.

7. ການແກ້ໄຂບັນຫາ

If you encounter issues with your VC1G Valve Core Remover, refer to the following common problems and solutions.

ບັນຫາສາເຫດທີ່ເປັນໄປໄດ້ການແກ້ໄຂ
Difficulty engaging/removing valve core.Worn or damaged core tool tip; valve core is stuck or corroded.Inspect the core tool tip for damage and replace if necessary. Apply penetrating oil to the valve core if it appears stuck. Ensure the tool is properly aligned.
Refrigerant leakage during operation.Damaged O-rings or seals; loose connections; debris on sealing surfaces.Inspect and replace any worn or damaged O-rings/seals. Ensure all connections are tightened securely. Clean sealing surfaces thoroughly before connecting.
Sight glass remains cloudy or shows bubbles after vacuum.Incomplete vacuum; moisture in the system.Ensure the vacuum pump is operating correctly and the system is pulled to a deep vacuum (20 microns or lower). Allow sufficient time for dehydration. Check for leaks in the system or connections.

8. ຂໍ້ມູນຈໍາເພາະ

Key technical specifications for the Fieldpiece VC1G Valve Core Remover.

Fieldpiece VC1G Valve Core Remover with specifications

Image: Fieldpiece VC1G Valve Core Remover with detailed specifications.

  • ຕົວແບບ: VC1G
  • ຍີ່ຫໍ້: ສະ ໜາມ
  • ນ້ໍາຫນັກລາຍການ: 12 ອອນ
  • ຂະໜາດແພັກເກດ: 7.91 x 3.5 x 2.28 ນິ້ວ
  • UPC: 872641005542
  • ຄະແນນສູນຍາກາດ: 220 microns / 0.027 millibar / 0.020 Torr
  • ຄວາມກົດດັນໃນການເຮັດວຽກສູງສຸດ: 800 psi / 55 Bar
  • ຂະໜາດ: 5.06" x 2" x 1.5"
  • ນ້ຳໜັກ: 0.6 lbs / 272 g
  • ສີ: Clear or White (referring to the sight glass or specific components)
Fieldpiece VC1G Valve Core Remover product shot

ຮູບພາບ: ທາງຫນ້າ view of the Fieldpiece VC1G Valve Core Remover.

ວັດສະດຸ:

  • ການກໍ່ສ້າງ: Aluminum body with brass fittings.

9. ການຮັບປະກັນແລະການສະ ໜັບ ສະ ໜູນ

Fieldpiece stands behind the quality of its products. For warranty information, technical support, or service inquiries, please refer to the official Fieldpiece webເວັບໄຊ ຫຼືຕິດຕໍ່ບໍລິການລູກຄ້າຂອງເຂົາເຈົ້າໂດຍກົງ.

ຮັກສາຫຼັກຖານການຊື້ຂອງທ່ານສໍາລັບການຮຽກຮ້ອງການຮັບປະກັນໃດໆ.

ສໍາລັບຊັບພະຍາກອນເພີ່ມເຕີມແລະຂໍ້ມູນຜະລິດຕະພັນ, ໄປຢ້ຽມຢາມ ຮ້ານ Fieldpiece ໃນ Amazon.

ເອກະສານທີ່ກ່ຽວຂ້ອງ - VC1G

ກ່ອນview ຄູ່ມືຜູ້ໃຊ້ທໍ່ລະບາຍຄວາມຮ້ອນ Fieldpiece SMAN®
ຄູ່ມືຜູ້ໃຊ້ສຳລັບທໍ່ສົ່ງນ້ຳຢາເຮັດຄວາມເຢັນ Fieldpiece SMAN® ພ້ອມດ້ວຍເຄື່ອງວັດແທກສູນຍາກາດໃນຕົວ (ລຸ້ນ SM382V ແລະ SM482V), ເຊິ່ງລະບຸລາຍລະອຽດກ່ຽວກັບຄຸນສົມບັດ, ການເຮັດວຽກ, ລາຍລະອຽດສະເພາະ ແລະ ການບຳລຸງຮັກສາສຳລັບຜູ້ຊ່ຽວຊານດ້ານ HVACR.
ກ່ອນview Fieldpiece SMAN® Coletor de Refrigerante com Vacuómetro Incorporado - ຄູ່ມືປະຕິບັດການ
Manual do operador detalhado para os coletores de refrigerante Fieldpiece SMAN® com vacuómetro incorporado (modelos SM382VINT e SM482VINT). Abrange operação, segurança, manutenção e especificações para profissionais de HVACR.
ກ່ອນview Manuel d'utilisation des manifolds pour fluide frigorigène Fieldpiece SMAN® avec jauge à vide intégrée
Manuel d'utilisation complet pour les manifolds pour fluide frigorigène Fieldpiece SMAN® modèles SM382VINT (3 ພອດ) ແລະ SM482VINT (4 ພອດ). Ce document couvre les caractéristiques, le fonctionnement, les procédures de sécurité, l'entretien, les spécifications techniques et le dépann#age.
ກ່ອນview Fieldpiece VP55/VP85 Vacuum Pump Operator's Manual - RunQuick Oil Change System
Operator's manual for Fieldpiece VP55 and VP85 vacuum pumps featuring the RunQuick™ Oil Change System. Covers operation, maintenance, safety, troubleshooting, and specifications for HVAC/R professionals.
ກ່ອນview ຄູ່ມືຜູ້ໃຊ້ Fieldpiece SM480V SMAN Refrigerant Manifold + Micron Gauge
ຄູ່ມືຜູ້ປະຕິບັດງານທີ່ຄົບຖ້ວນສຳລັບເຄື່ອງວັດແທກທໍ່ສົ່ງນ້ຳຢາເຮັດຄວາມເຢັນ Fieldpiece SM480V SMAN ແລະ Micron Gauge, ເຊິ່ງລະບຸລາຍລະອຽດກ່ຽວກັບຄຸນສົມບັດ, ການດຳເນີນງານ, ການບຳລຸງຮັກສາ, ລາຍລະອຽດສະເພາະ ແລະ ການປະຕິບັດຕາມຂໍ້ກຳນົດສຳລັບຜູ້ຊ່ຽວຊານດ້ານ HVACR. ກວມເອົາການຕັ້ງຄ່າ, ການວັດແທກ, ການຄິດໄລ່, ໜ້າທີ່ຂອງເມນູ ແລະ ການແກ້ໄຂບັນຫາ.