This manual provides comprehensive instructions for the installation, operation, and maintenance of your ECOELER YWT102 Countdown Timer Switch. This in-wall timer switch is designed to automatically turn off connected loads such as lights, ceiling fans, bathroom fans, and heaters after a preset time, contributing to energy savings and convenience. It features multiple preset countdown options and a manual override function.

Image: The ECOELER Countdown Timer Switch in Ivory, shown as a 2-pack.
ຄຸນສົມບັດຜະລິດຕະພັນ
- 8 Pre-Set Options: Offers countdown settings of 1 minute, 5 minutes, 10 minutes, 15 minutes, 30 minutes, 60 minutes, 2 hours, or 4 hours.
- ຍົກເລີກຄູ່ມື: Allows instant ON/OFF control, overriding any active countdown.
- ການປະຫຍັດພະລັງງານ: Automatically turns off loads, preventing accidental energy waste. Ideal for lights, ceiling fans, bathroom fans, and heaters.
- ການດໍາເນີນງານງ່າຍດາຍ: Features Countdown mode and Constant On mode. Select time with a button press; hold ON/OFF for 5 seconds to activate Constant On.
- ຕົວຊີ້ວັດ LED: An always-on LED light makes the switch easy to locate in low-light conditions.
- ຄໍາຮ້ອງສະຫມັກກ້ວາງ: Suitable for bathrooms, closets, pantries, garages, laundry rooms, spas, and enclosed patios.
- ປອດໄພ ແລະເຊື່ອຖືໄດ້: ETL listed, supporting LED/CFL, Incandescent (800W), Fluorescent (1200VA) light bulbs, and motors (1/2 HP).

ຮູບພາບ: ລາຍລະອຽດ view of the ECOELER Countdown Timer Switch buttons and LED indicator labels, highlighting its features.
ເນື້ອໃນຊຸດ
Upon opening your ECOELER Countdown Timer Switch package, you should find the following items:
- ECOELER YWT102 Countdown Timer Switch
- Matching Wall Plate
- ເສັ້ນລວດ
- ຄູ່ມືການຕິດຕັ້ງ

Image: The ECOELER Countdown Timer Switch, wire nuts, and face plate, along with product dimensions.
ຂໍ້ມູນຄວາມປອດໄພ
ຄຳເຕືອນ: To prevent serious injury or death from electric shock, always turn OFF the power at the circuit breaker or fuse box before wiring. This device is intended for installation in accordance with the National Electric Code and local regulations. Use copper wires only. If you are unsure about any part of these instructions, consult a qualified electrician.
ຂໍ້ມູນຈໍາເພາະ
| ຂໍ້ມູນຈໍາເພາະ | ມູນຄ່າ |
|---|---|
| ຍີ່ຫໍ້ | ECOELER |
| ໝາຍເລກຕົວແບບ | YWT102 |
| ສີ | ງາຊ້າງ |
| ຂະໜາດສິນຄ້າ | 4.19 x 3.71 x 11.99 cm |
| ພະລັງງານ/ວັດtage | 1800 ວັດ |
| ວັດສະດຸ | Copper, Metal, Polycarbonate |
| ນ້ໍາຫນັກລາຍການ | 136 g |
| ຮູບແບບການເຮັດວຽກ | ປິດແລ້ວ |
| ການຈັດອັນດັບປັດຈຸບັນ | 15 Amps |
| ການດໍາເນີນງານ Voltage | 120 ໂວນ (AC) |
| ປະເພດການຕິດຕໍ່ | ເປີດປົກກະຕິ |
| ປະເພດສະຫຼັບ | ປຸ່ມກົດ |
| ສະຖານີ | Wiring Lead |
ການຕິດຕັ້ງ
Follow these steps carefully to install your ECOELER Countdown Timer Switch. If you are not comfortable performing electrical work, please consult a qualified electrician.
ການຕິດຕັ້ງກ່ອນ
- ປິດໄຟ: Locate your circuit breaker panel and turn off the power to the switch box where you will be installing the timer. Verify that the power is off using a voltage ເຄື່ອງທົດສອບ.
- ລຶບສະວິດທີ່ມີຢູ່ແລ້ວອອກ: Carefully remove the screws holding the existing wall plate and switch. Gently pull the switch out of the wall box.
- ກໍານົດສາຍ: Identify the wires connected to your existing switch. Typically, you will find:
- Hot Wire: Usually black, brings power from the circuit breaker.
- ໂຫຼດສາຍ: Usually black or red, carries power to the light/fan.
- ສາຍກາງ: ປົກກະຕິແລ້ວສີຂາວ. A neutral wire is required for this timer switch.
- ສາຍດິນ: ໂດຍປົກກະຕິແລ້ວມີສີຂຽວ ຫຼື ທອງແດງເປົ່າ.
ການເຊື່ອມຕໍ່ສາຍໄຟ
Connect the wires from the wall box to the ECOELER Countdown Timer Switch as follows:

Image: Wiring diagram for the ECOELER Countdown Timer Switch, illustrating connections for Load (Red), Hot (Black), Ground (Green), and Neutral (White) wires. Note: Neutral Wire Must Be Required.
- ເຊື່ອມຕໍ່ ສາຍສີແດງ from the timer to the ໂຫຼດສາຍ from the wall box using a wire nut.
- ເຊື່ອມຕໍ່ ສາຍ ດຳ from the timer to the ສາຍໄຟຮ້ອນ from the wall box using a wire nut.
- ເຊື່ອມຕໍ່ ສາຍສີຂາວ from the timer to the ສາຍກາງ from the wall box using a wire nut.
- ເຊື່ອມຕໍ່ ສາຍສີຂຽວ from the timer to the ສາຍດິນ from the wall box using a wire nut.
ຫລັງການຕິດຕັ້ງ
- ຄ່ອຍໆຍູ້ສາຍໄຟທັງໝົດກັບຄືນເຂົ້າໄປໃນກ່ອງຕິດຝາ.
- Secure the timer switch to the wall box with the provided screws.
- Attach the new wall plate over the timer switch.
- ຟື້ນຟູພະລັງງານ: Return to your circuit breaker panel and turn the power back ON.
ຄໍາແນະນໍາການດໍາເນີນງານ
The ECOELER Countdown Timer Switch offers two primary operating modes: Countdown Mode and Constant On Mode.
ແບບນັບຖອຍຫລັງ
To activate a countdown:
- Press the desired time button (1 Min, 5 Min, 10 Min, 15 Min, 30 Min, 60 Min, 2 Hour, or 4 Hour).
- The corresponding LED indicator will illuminate, and the countdown will begin.
- The connected load (light, fan, etc.) will turn off automatically once the selected time expires.
- To cancel a countdown manually, press the large ON/OFF button at the bottom.
Constant On Mode (Manual Override)
To keep the connected load continuously ON, bypassing the timer function:
- Press and hold the large ON/OFF button at the bottom for more than 5 seconds.
- The load will remain ON until the ON/OFF button is pressed again to turn it off.

Image: The ECOELER Countdown Timer Switch with its LED indicator illuminated, making it visible in a dark environment.
ບໍາລຸງຮັກສາ
The ECOELER Countdown Timer Switch requires minimal maintenance. To ensure optimal performance and longevity:
- Keep the switch and wall plate clean by wiping with a soft, damp ຜ້າ. ຫຼີກລ້ຽງການເຮັດຄວາມສະອາດຂັດຫຼືສານລະລາຍ.
- Ensure the switch is not exposed to excessive moisture or extreme temperatures.
- Periodically check the connections for any signs of loosening, though this should only be done with the power turned off at the circuit breaker.
ການແກ້ໄຂບັນຫາ
If you encounter issues with your ECOELER Countdown Timer Switch, consider the following:
- ສະຫຼັບບໍ່ຕອບສະໜອງ: Ensure the power is ON at the circuit breaker. Check all wire connections for tightness.
- Load Not Turning Off: Verify that the switch is not in Constant On mode (manual override). If it is, press the ON/OFF button to turn it off.
- ຕົວຊີ້ວັດ LED ບໍ່ສະຫວ່າງ: Check power supply and connections. If the switch is functioning otherwise, the LED might be faulty, but this is rare.
- ການດໍາເນີນງານແບບບໍ່ຢຸດຢັ້ງ: Ensure all wire connections are secure. Loose connections can cause inconsistent performance.
If problems persist after checking these points, please contact customer support.
ການຮັບປະກັນແລະການສະຫນັບສະຫນູນ
The ECOELER Countdown Timer Switch comes with a ຮັບປະກັນ 1 ປີ. For any questions, technical assistance, or warranty claims, please contact ECOELER customer support. You can reach us via email at SUPPORTS@ECOELER.COM. We aim to respond to all inquiries within 24 hours.
Manufacturer: ECOELER ELECTRIC INC