UNI-T UPO1102

UNI-T UPO1102 100MHz 2-Channel Digital Oscilloscope Instruction Manual

Model: UPO1102

1. ບົດແນະນຳ

This instruction manual provides essential information for the safe and effective use of the UNI-T UPO1102 100MHz 2-Channel Digital Oscilloscope. The UPO1102 is a versatile instrument designed for electronic and electrical measurements, featuring a 100MHz bandwidth, 1 GSa/s real-time sample rate, 56 Mpts memory depth, and a 7-inch display. It incorporates Ultra Phosphor technology for enhanced waveform display and analysis capabilities.

ກະລຸນາອ່ານຄູ່ມືນີ້ຢ່າງລະອຽດກ່ອນທີ່ຈະໃຊ້ງານອຸປະກອນເພື່ອຮັບປະກັນການເຮັດວຽກທີ່ເໝາະສົມ ແລະ ເພື່ອປ້ອງກັນຄວາມເສຍຫາຍ.

2. ຂໍ້ມູນຄວາມປອດໄພ

Always observe the following safety precautions to avoid personal injury and prevent damage to the instrument or other connected devices.

3. ຜະລິດຕະພັນເກີນview

3.1 ກະດານດ້ານ ໜ້າ

ດ້ານໜ້າ view of the UNI-T UPO1102 Digital Oscilloscope, showing the 7-inch display, control knobs, and input connectors.

Figure 3.1: Front Panel of UPO1102 Oscilloscope

The front panel features the main display, various control knobs and buttons for waveform adjustment, trigger settings, and menu navigation. Input channels CH1 and CH2 are located at the bottom right.

3.2 ແຜງດ້ານຫລັງ

ຫລັງ view of the UNI-T UPO1102 Digital Oscilloscope, showing the power input, USB ports, and ventilation.

Figure 3.2: Rear Panel of UPO1102 Oscilloscope

The rear panel includes the AC power input, USB ports for data transfer and printing, and ventilation grilles to ensure proper cooling during operation.

3.3 ຂະໜາດ

Dimensions of the UNI-T UPO1102 Digital Oscilloscope, showing a width of 13.23 inches, height of 6.46 inches, and depth of 4.13 inches.

Figure 3.3: UPO1102 Oscilloscope Dimensions

The physical dimensions of the UPO1102 are approximately 13.23 inches (width) x 6.46 inches (height) x 4.13 inches (depth).

4. ຕັ້ງຄ່າ

4.1 ການຫຸ້ມຫໍ່ແລະການກວດກາ

Upon receiving your UPO1102 oscilloscope, carefully unpack all components and inspect them for any signs of damage. Retain the packaging for future transport or storage.

ອຸປະກອນເສີມມາດຕະຖານ:

4.2 ການເຊື່ອມຕໍ່ພະລັງງານ

  1. Ensure the oscilloscope is placed on a stable, level surface with adequate ventilation.
  2. Connect the provided power cord to the AC power input on the rear panel of the oscilloscope.
  3. ສຽບປາຍອີກດ້ານໜຶ່ງຂອງສາຍໄຟເຂົ້າກັບປລັກໄຟ AC ທີ່ມີສາຍດິນ.
  4. ກົດປຸ່ມເປີດ/ປິດຢູ່ເທິງແຜງດ້ານໜ້າເພື່ອເປີດອອດຊິວໂລສະໂຄບ.

4.3 ການເຊື່ອມຕໍ່ Probe ແລະການຊົດເຊີຍ

Before taking measurements, it is crucial to compensate the probes to ensure accurate readings.

  1. Connect a probe to one of the input channels (CH1 or CH2) on the front panel.
  2. Connect the probe tip to the "Probe Comp" terminal and the ground clip to the ground terminal next to it.
  3. ກົດ ອັດຕະໂນມັດ button. The oscilloscope will automatically adjust the settings to display the compensation signal.
  4. Observe the square wave displayed on the screen. If the waveform is not a perfect square (over-compensated or under-compensated), adjust the trimmer on the probe body using a non-metallic tool until a flat-top square wave is achieved.
  5. Repeat for the second probe if using both channels.
Example of a square wave displayed on the oscilloscope screen during probe compensation.

Figure 4.1: Probe Compensation Waveform

A correctly compensated probe displays a clean square wave. Adjust the probe's trimmer if the waveform shows overshoot or undershoot.

5. ຄໍາແນະນໍາການດໍາເນີນງານ

5.1 ການຄວບຄຸມພື້ນຖານ

5.2 Waveform Acquisition and Display

The UPO1102 features a 7-inch display and Ultra Phosphor technology for clear waveform visualization, even with complex signals.

Oscilloscope display showing a complex waveform with varying intensity, demonstrating Ultra Phosphor technology.

Figure 5.1: Ultra Phosphor Display

Ultra Phosphor technology provides a gradient display, where brighter areas indicate more frequent occurrences of the waveform, helping to visualize signal anomalies and variations.

Oscilloscope display showing two overlaid waveforms, demonstrating multi-channel measurement.

Figure 5.2: Multi-Channel Waveform Display

The UPO1102 can display and analyze two channels simultaneously, allowing for comparison of different signals.

5.3 ຫນ້າທີ່ການວັດແທກ

5.4 Digital Decoding

The innovative hardware decoding feature allows for real-time decoding of serial bus protocols. With a deep storage of 56 Mpts, decoding speed is maintained at millisecond levels, preventing delays when viewing decoded data. This function does not affect the waveform refresh rate, maintaining the digital fluorescence display effect.

Oscilloscope display showing decoded serial data alongside the raw waveform.

Figure 5.4: Digital Decoding Example

The decoding feature displays protocol information directly on the screen, simplifying debugging of serial communications.

5.5 ການເກັບຮັກສາຂໍ້ມູນ ແລະ ການເຊື່ອມຕໍ່

6. ບໍາລຸງຮັກສາ

6.1 ການເບິ່ງແຍງທົ່ວໄປ

6.2 ການທໍາຄວາມສະອາດ

To clean the exterior of the oscilloscope:

  1. Disconnect the power cord and all probes/cables.
  2. ໃຊ້ຜ້າອ່ອນ ງampened with mild detergent and water. Do not use abrasive cleaners or solvents.
  3. For the display, use a soft, lint-free cloth specifically designed for electronic screens.
  4. Ensure the instrument is completely dry before reconnecting power.

7. ການແກ້ໄຂບັນຫາ

This section addresses common issues you might encounter with the UPO1102 oscilloscope. For problems not listed here, contact UNI-T customer support.

ບັນຫາສາເຫດທີ່ເປັນໄປໄດ້ການແກ້ໄຂ
ບໍ່ມີການສະແດງຜົນຫຼັງຈາກເປີດໄຟ.Power cord not connected, power outlet faulty, instrument fault.Check power cord connection. Test power outlet. If problem persists, contact support.
ບໍ່ມີຮູບແບບຄື້ນສະແດງ.ບໍ່ໄດ້ເຊື່ອມຕໍ່ Probe, ສັນຍານນ້ອຍ/ໃຫຍ່ເກີນໄປ, Trigger ບໍ່ໄດ້ຕັ້ງຢ່າງຖືກຕ້ອງ, ປິດຊ່ອງ.Ensure probe is connected to signal source. Press ອັດຕະໂນມັດ button. Adjust vertical scale (Volts/Div) and horizontal scale (Sec/Div). Check trigger level. Ensure channel is enabled.
ຮູບແບບຄື້ນບໍ່ສະຖຽນ.Trigger level incorrect, trigger mode unsuitable, signal noise.Adjust trigger level. Try different trigger modes (e.g., Normal or Single). Reduce noise in the signal path.
ການວັດແທກບໍ່ຖືກຕ້ອງ.Probe compensation incorrect, probe attenuation setting wrong, measurement settings incorrect.Perform probe compensation (Section 4.3). Verify probe attenuation setting matches physical probe (e.g., 1X, 10X). Check measurement parameters.

8. ຂໍ້ມູນຈໍາເພາະ

ພາລາມິເຕີມູນຄ່າ
ແບນວິດ100 MHz
ຊ່ອງ2
ເວລາຈິງ S.ampອັດຕາ le1 GSa/ວິ
ຄວາມເລິກຂອງຫນ່ວຍຄວາມຈໍາ56 Mpts
ອັດຕາການຈັບພາບຄື້ນ500,000 wfm/s
ຈໍສະແດງຜົນ7 ນິ້ວ
FFT Sampຈຸດ ling1 Mpts
ຂະໜາດສິນຄ້າ13 x 4 x 6 ນິ້ວ (ປະມານ 330 x 102 x 152 ມມ)
ນ້ໍາຫນັກລາຍການ8.13 ປອນ (ປະມານ 3.69 ກິ​ໂລ​)
ຜູ້ຜະລິດUNI-T
ASINB0D7F2D9MS
ວັນທີທໍາອິດທີ່ມີວັນທີ 19 ມິຖຸນາ 2024

9. ການຮັບປະກັນແລະການສະຫນັບສະຫນູນ

For warranty information, technical support, or service inquiries regarding your UNI-T UPO1102 oscilloscope, please refer to the official UNI-T webເວັບໄຊ ຫຼືຕິດຕໍ່ພະແນກບໍລິການລູກຄ້າຂອງເຂົາເຈົ້າ.

UNI-T Official Store: Visit the UNI-T Store on Amazon

Please have your product model (UPO1102) and ASIN (B0D7F2D9MS) available when contacting support.