1. ບົດແນະນຳ
The ELEGRP Extension Cord Ends are designed for replacing worn or damaged plugs and connectors on existing extension cords, or for creating custom-length cords. This set includes both a male plug (NEMA 5-15P) and a female connector (NEMA 5-15R), rated for 15 Amps and 125 Volts, featuring a 2-pole, 3-wire grounding design. These components are UL Listed, ensuring compliance with safety standards for reliable electrical connections.

ຮູບພາບ 1.1: ຫຼາຍກວ່າview of ELEGRP 2-Pole, 3-Wire Grounding Plugs and Connectors (NEMA 5-15P and NEMA 5-15R).
2. ຂໍ້ມູນຄວາມປອດໄພ
Please read and understand all safety instructions before installation and use. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- ຕັດການເຊື່ອມຕໍ່ໄຟຟ້າສະເໝີ to the circuit before working with electrical components.
- Ensure the wire gauge of your extension cord is compatible with these connectors (recommended #14 AWG).
- Verify all wire connections are secure and properly insulated to prevent short circuits.
- Do not exceed the rated capacity of 15 Amps, 125 Volts, or 1875 Watts.
- Ensure proper grounding by connecting the green wire to the ground terminal.
- Consult a qualified electrician if you are unsure about any installation steps or electrical safety procedures.
- Keep children and pets away from electrical work areas.
3. ເນື້ອໃນຊຸດ
Each set typically includes the following components:
- 1x ELEGRP Straight Blade Male Plug (NEMA 5-15P)
- 1x ELEGRP Straight Blade Female Connector (NEMA 5-15R)
4. ຂໍ້ມູນຈໍາເພາະ
| ຄຸນສົມບັດ | ຂໍ້ມູນຈໍາເພາະ |
|---|---|
| ລາຍລະອຽດ | 2-pole, 3-wire grounding |
| ຄະແນນ | 15A 125V |
| ການຕັ້ງຄ່າ NEMA | 5-15P (Plug) / 5-15R (Connector) |
| ອັດຕາການຕິດໄຟ | Rated V-2 per UL94 |
| ແນະນໍາ Wire Gauge | #14 AWG |
| ການລະບຸຕົວຕົນຂອງສະຖານີ | Brass-Hot, Green-Ground, Silver-Neutral |
| ອຸນຫະພູມປະຕິບັດການ | -40°C ເຖິງ 60°C |
| ວັດສະດຸ | Insulated and Solid Nylon Housing, Brass Contacts |
| ການຢັ້ງຢືນ | UL ລາຍຊື່ (File E355464) |

Image 4.1: Detailed product specifications and dimensions for the ELEGRP plug and connector.
5. ການຕິດຕັ້ງແລະການຕິດຕັ້ງ
Follow these steps to safely install the ELEGRP replacement plug or connector onto your extension cord.
- ກະກຽມສາຍ: Carefully cut the damaged end of your extension cord. Using a wire stripper, remove approximately 1 inch of the outer jacket from the cord. Then, strip about 1/2 inch of insulation from each of the three inner wires (Hot, Neutral, Ground).
- Disassemble the Plug/Connector: Unscrew the single screw on the housing of the ELEGRP plug or connector and separate the two halves.
- ກະທູ້ສາຍ: Slide the outer housing piece onto the prepared extension cord. Ensure it is oriented correctly so it can be reassembled later.
- ເຊື່ອມຕໍ່ສາຍ:
- Twist the strands of each wire tightly.
- Identify the terminals: The ທອງເຫຼືອງ screw is for the ຮ້ອນ wire (usually black). The ເງິນ screw is for the ເປັນກາງ wire (usually white). The ສີຂຽວ screw is for the ດິນ wire (usually green or bare copper).
- Loosen the terminal screws. Wrap each wire clockwise around its corresponding screw terminal and tighten securely. Ensure no stray wire strands are present.
- ການບັນເທົາຄວາມເຄັ່ງຕຶງທີ່ປອດໄພ: The internal design provides a strain relief mechanism. Ensure the conductor is wrapped around the brass contact for additional strain relief before fully tightening the terminal screws.
- ການປະກອບທີ່ຢູ່ອາໄສ: Carefully align the two halves of the plug or connector housing, ensuring all wires are tucked inside and not pinched. Secure the housing by tightening the single screw.

Image 5.1: Visual guide for fast and easy assembly, showing wire connections and terminal identification.


ຮູບພາບທີ 5.2: ໄລຍະໃກ້ views of wiring for the male plug and female connector.
6. ຄໍາແນະນໍາການດໍາເນີນງານ
Once the ELEGRP plug or connector is securely installed on your extension cord:
- Ensure all connections are tight and the housing is fully closed.
- Plug the male end (NEMA 5-15P) into a compatible 125V grounded electrical outlet.
- Connect the female end (NEMA 5-15R) to the desired appliance or tool.
- Always ensure the total current draw of connected devices does not exceed 15 Amps.
- To disconnect, grasp the plug or connector firmly and pull straight out from the outlet or appliance. Avoid pulling by the cord itself.

ຮູບພາບ 6.1: ຕົວຢ່າງample of an extension cord assembled with ELEGRP ends, ready for use.
7. ບໍາລຸງຮັກສາ
Regular maintenance helps ensure the longevity and safe operation of your ELEGRP extension cord ends.
- ກວດສອບເປັນປົກກະຕິ: Periodically check the plug and connector for any signs of physical damage, cracks in the housing, frayed wires, or discoloration from overheating.
- ກວດສອບການເຊື່ອມຕໍ່: If you notice any intermittent power or flickering, disconnect the cord and re-check the internal wire connections. Re-tighten any loose terminal screws.
- ຮັກສາຄວາມສະອາດ: Ensure the contacts are free from dirt, dust, or corrosion. Use a dry cloth to wipe clean if necessary.
- ການເກັບຮັກສາ: Store extension cords with ELEGRP ends in a dry, cool place when not in use. Avoid extreme temperatures.
8. ການແກ້ໄຂບັນຫາ
If you encounter issues with your ELEGRP extension cord ends, refer to the following troubleshooting guide:
| ບັນຫາ | ສາເຫດທີ່ເປັນໄປໄດ້ | ການແກ້ໄຂ |
|---|---|---|
| ບໍ່ມີໄຟກັບອຸປະກອນ |
|
|
| Plug/Connector feels hot |
|
|
| ພະລັງງານແບບບໍ່ຢຸດຢັ້ງ |
|
|
9. ການຮັບປະກັນແລະການສະຫນັບສະຫນູນ
For warranty information or technical support, please refer to the ELEGRP official webເວັບໄຊ ຫຼືຕິດຕໍ່ບໍລິການລູກຄ້າຂອງເຂົາເຈົ້າໂດຍກົງ. ຮັກສາໃບຮັບເງິນການຊື້ຂອງທ່ານໄວ້ເປັນຫຼັກຖານການຊື້.