1. ບົດແນະນຳ
This manual provides comprehensive instructions for the installation, operation, and maintenance of the Axis Communications D8208-R Industrial 8-Port Managed PoE++ Switch. This device is designed for robust industrial environments, offering reliable network connectivity and Power over Ethernet (PoE++) capabilities for connected devices. Please read this manual thoroughly before using the product to ensure proper and safe operation.
2. ຂໍ້ມູນຄວາມປອດໄພ
ປະຕິບັດຕາມຄວາມລະມັດລະວັງດ້ານຄວາມປອດໄພຕໍ່ໄປນີ້ເພື່ອປ້ອງກັນຄວາມເສຍຫາຍຂອງຜະລິດຕະພັນແລະຮັບປະກັນຄວາມປອດໄພຂອງຜູ້ໃຊ້:
- ແຫຼ່ງພະລັງງານ: Use only the specified power supply for this device. Ensure the power source meets the voltage ແລະຄວາມຕ້ອງການໃນປະຈຸບັນ.
- ສະພາບແວດລ້ອມ: Install the switch in an environment that complies with its operating temperature and humidity specifications. Avoid exposure to direct sunlight, excessive heat, moisture, or corrosive substances.
- ການລະບາຍອາກາດ: ຮັບປະກັນການລະບາຍອາກາດທີ່ພຽງພໍອ້ອມຮອບອຸປະກອນເພື່ອປ້ອງກັນຄວາມຮ້ອນເກີນໄປ. ຢ່າອຸດຕັນຊ່ອງລະບາຍອາກາດ.
- ການຕິດຕັ້ງ: ການຕິດຕັ້ງຄວນໄດ້ຮັບການປະຕິບັດໂດຍບຸກຄະລາກອນທີ່ມີຄຸນວຸດທິຕາມລະຫັດແລະກົດລະບຽບໄຟຟ້າທ້ອງຖິ່ນ.
- ບໍາລຸງຮັກສາ: Do not attempt to open or service the device yourself. Refer all servicing to qualified service personnel.
- ສາຍໄຟ: Use appropriate and certified cables for all connections.
3. ເນື້ອໃນຊຸດ
Verify that all items are present in the package. If any item is missing or damaged, contact your supplier.
- AXIS D8208-R Industrial 8-Port Managed PoE++ Switch
- ຄູ່ມືການຕິດຕັ້ງດ່ວນ
- Mounting Kit (e.g., DIN rail clip, screws)
- Terminal Block Connectors (for power input)
4. ຜະລິດຕະພັນເກີນview
The AXIS D8208-R is a robust industrial switch designed for demanding applications. It features multiple Ethernet ports with Power over Ethernet capabilities and advanced management features.
4.1 ຮູບແບບແຜງດ້ານໜ້າ

ຮູບທີ 1: ດ້ານໜ້າ view of the AXIS D8208-R Industrial Switch. This image displays the front panel of the switch, highlighting the various Ethernet ports, power input terminals, LED indicators, and the console port. Ports 1-4 are 1G PoE++ ports, ports 5-8 include 1G and 2.5G PoE++ capabilities, and ports 9-10 are 10G SFP+ ports.

ຮູບທີ 2: ລາຍລະອຽດດ້ານໜ້າ view of the AXIS D8208-R Industrial Switch. This image provides a closer look at the port configuration and LED indicators. It shows the two 10G SFP+ uplink ports (9 and 10) at the bottom, the console port, and the reset button. The power input terminals are visible on the right side.
4.2 Components Description
- ຜອດອີເທີເນັດ (1-4): 1 Gigabit Ethernet ports with PoE++ (802.3bt) support.
- ຜອດອີເທີເນັດ (5-8): 1 Gigabit and 2.5 Gigabit Ethernet ports with PoE++ (802.3bt) support.
- 10G Ports (9-10): 10 Gigabit SFP+ uplink ports for high-speed connections.
- Power Input (P1, P2): Redundant power input terminals for enhanced reliability.
- ຜອດຄອນໂຊນ: ພອດ RJ45 ສຳລັບການຄຸ້ມຄອງທ້ອງຖິ່ນ ແລະ ການຕັ້ງຄ່າຜ່ານການເຊື່ອມຕໍ່ແບບ serial.
- ປຸ່ມຣີເຊັດ: ໃຊ້ເພື່ອຕັ້ງຄ່າອຸປະກອນຄືນໃໝ່ໃຫ້ເປັນຄ່າເລີ່ມຕົ້ນຈາກໂຮງງານ ຫຼື ປິດເປີດເຄື່ອງໃໝ່.
- ຕົວຊີ້ວັດ LED:
- SYS: ຕົວຊີ້ບອກສະຖານະຂອງລະບົບ.
- P1, P2: Power input status indicators.
- ALM: ຕົວຊີ້ບອກປຸກ.
- RM, RC: Redundancy Management / Redundancy Control indicators.
5. ຕັ້ງຄ່າ
5.1 ການຕິດຕັ້ງ
The AXIS D8208-R is designed for DIN rail mounting.
- Attach the DIN rail clip (if not pre-installed) to the rear of the switch using the provided screws.
- Hook the top edge of the DIN rail clip onto the DIN rail.
- Push the bottom of the switch firmly towards the DIN rail until it clicks into place.
- Ensure the switch is securely fastened to the DIN rail.
5.2 ການເຊື່ອມຕໍ່ພະລັງງານ
The switch supports redundant power inputs (P1 and P2) for increased reliability.
- Ensure the power source is turned off before making any connections.
- Connect the positive (+) and negative (-) wires from your DC power supply to the corresponding terminals on the provided terminal block connector for P1.
- Insert the terminal block connector into the P1 power input port on the switch.
- (Optional) For redundant power, repeat steps 2 and 3 for the P2 power input.
- Once all connections are secure, turn on the power supply. The P1 and/or P2 LEDs should illuminate.
5.3 ການເຊື່ອມຕໍ່ເຄືອຂ່າຍ
Connect network devices and uplink connections.
- Standard Devices: Connect your network devices (e.g., IP cameras, access points) to ports 1-8 using standard Ethernet cables. These ports will provide PoE++ power if the connected device supports it.
- Uplink: For high-speed uplink to your core network, insert compatible SFP+ transceivers into ports 9 and 10, then connect fiber optic cables.
5.4 ການຕັ້ງຄ່າເບື້ອງຕົ້ນ
ສະຫຼັບສາມາດຕັ້ງຄ່າໄດ້ຜ່ານທາງ web-based interface or a command-line interface (CLI) through the console port.
- Web ການໂຕ້ຕອບ: Connect a computer to any Ethernet port on the switch. The switch will typically obtain an IP address via DHCP or use a default static IP. Refer to the Quick Installation Guide for the default IP address and login credentials.
- ຜອດຄອນໂຊນ: Connect a serial cable from your computer to the console port on the switch. Use a terminal emulation program (e.g., PuTTY) with the specified serial settings (e.g., 115200 baud, 8 data bits, no parity, 1 stop bit, no flow control) to access the CLI.
6. ການເຮັດວຽກ
6.1 ຕົວຊີ້ວັດ LED
Monitor the LED indicators for the operational status of the switch.
| LED | ສະຖານະ | ລາຍລະອຽດ |
|---|---|---|
| SYS | ສີຂຽວ (ແຂງ) | ລະບົບເຮັດວຽກເປັນປົກກະຕິ. |
| SYS | ສີຂຽວ (ກະພິບ) | System is booting or performing an operation. |
| P1/P2 | ສີຂຽວ (ແຂງ) | Corresponding power input is active. |
| ALM | Red (Solid/Flashing) | An alarm condition exists (e.g., power failure, port error). Check system logs. |
| ໄຟ LED Port | ສີຂຽວ (ແຂງ) | ສ້າງການເຊື່ອມຕໍ່. |
| ໄຟ LED Port | ສີຂຽວ (ກະພິບ) | ກິດຈະກຳຂໍ້ມູນ. |
6.2 ການຈັດການ ແລະການຕັ້ງຄ່າ
The AXIS D8208-R is a managed switch, offering a range of configuration options for network optimization and security.
- Web-GUI ອີງໃສ່: ເຂົ້າເຖິງສະວິດ web interface via a standard web browser to configure VLANs, QoS, port settings, PoE management, security features, and more.
- CLI: For advanced users, the Command Line Interface provides granular control over all switch functions.
- SNMP: The switch supports SNMP for integration with network management systems.
7. ບໍາລຸງຮັກສາ
7.1 ການທໍາຄວາມສະອາດ
To maintain optimal performance, periodically clean the exterior of the switch.
- ໃຫ້ແນ່ໃຈວ່າໄດ້ຕັດການເຊື່ອມຕໍ່ກ່ອນທີ່ຈະທໍາຄວາມສະອາດ.
- ໃຊ້ຜ້າປຽກອ່ອນໆເຊັດພື້ນຜິວພາຍນອກ.
- ຢ່າໃຊ້ນໍ້າຢາລ້າງຂອງແຫຼວ ຫຼື ນໍ້າຢາສີດ, ເພາະມັນອາດຈະເຮັດໃຫ້ອຸປະກອນເສຍຫາຍໄດ້.
- ຮັກສາຊ່ອງລະບາຍອາກາດໃຫ້ສະອາດຂອງຂີ້ຝຸ່ນແລະສິ່ງເສດເຫຼືອ.
7.2 ການອັບເດດເຟີມແວ
Regularly check the Axis Communications webເວັບໄຊທ໌ສໍາລັບການອັບເດດເຟີມແວຫຼ້າສຸດ. ການອັບເດດເຟີມແວສາມາດສະໜອງຄຸນສົມບັດໃໝ່, ການປັບປຸງປະສິດທິພາບ ແລະການປັບປຸງຄວາມປອດໄພ.
- ດາວໂຫລດເຟີມແວທີ່ເຫມາະສົມ file from the official Axis Communications support page for your model.
- Follow the instructions provided with the firmware update package for the correct update procedure, typically performed via the web ການໂຕ້ຕອບ.
8. ການແກ້ໄຂບັນຫາ
If you encounter issues with your AXIS D8208-R switch, refer to the following common troubleshooting steps.
- ບໍ່ມີພະລັງງານ:
- Check power cable connections to the switch and the power source.
- ກວດສອບວ່າແຫຼ່ງຈ່າຍໄຟເຮັດວຽກຢ່າງຖືກຕ້ອງ ແລະ ໃຫ້ລະດັບສຽງທີ່ຖືກຕ້ອງtage.
- Ensure the P1/P2 LEDs are illuminated.
- ບໍ່ມີການເຊື່ອມຕໍ່ເຄືອຂ່າຍ:
- Check Ethernet cable connections for both the switch and the connected device.
- Verify the link/activity LEDs on the respective port are active.
- Ensure the connected device is powered on and configured correctly.
- Check switch configuration (VLANs, port status) via the web ການໂຕ້ຕອບຫຼື CLI.
- ອຸປະກອນ PoE ບໍ່ເປີດ:
- Ensure the connected device is PoE compatible and within the switch's PoE budget.
- Check the PoE status for the port in the switch's management interface.
- Verify the Ethernet cable is a standard Cat5e/6 or higher.
- ການເຂົ້າເຖິງ Web Interface Fails:
- Confirm your computer's IP address is in the same subnet as the switch, or that DHCP is functioning.
- Try accessing the switch via the console port to verify its IP configuration.
- ລຶບລ້າງແຄດຂອງບຼາວເຊີຂອງທ່ານ ຫຼືລອງໃຊ້ໂປຣແກຣມທ່ອງເວັບອື່ນ.
- ປັບຄ່າໂຮງງານ: If issues persist and you need to restore default settings, press and hold the reset button for approximately 10-15 seconds until the SYS LED changes behavior, then release. Warning: This will erase all custom configurations.
9. ຂໍ້ມູນຈໍາເພາະ
| ຄຸນສົມບັດ | ລາຍລະອຽດ |
|---|---|
| ຍີ່ຫໍ້ | ການສື່ສານແກນ |
| ໝາຍເລກຕົວແບບ | 02621-001 |
| ຊື່ຜະລິດຕະພັນ | AXIS D8208-R Industrial 8-Port Managed PoE++ Switch |
| ທ່າເຮືອ | 8 x PoE++ Ethernet (1G/2.5G), 2 x 10G SFP+ |
| ການປ້ອນຂໍ້ມູນພະລັງງານ | Redundant DC power input (terminal blocks) |
| ນ້ໍາຫນັກລາຍການ | 3.37 ປອນ (ປະມານ 1.53 ກິໂລ) |
| ຂະໜາດແພັກເກັດ | 1.97 x 0.79 x 0.79 ນິ້ວ (ປະມານ 5 x 2 x 2 ຊມ) |
| ຜູ້ຜະລິດ | AXIS - ACCESS CONTROL |
| ວັນທີທໍາອິດທີ່ມີ | ວັນທີ 29 ພຶດສະພາ 2024 |
10. ການຮັບປະກັນແລະການສະຫນັບສະຫນູນ
For detailed warranty information, technical support, and additional resources, please visit the official Axis Communications webເວັບໄຊ.
Webເວັບໄຊ: www.axis.com
Contact Axis Communications support for assistance with product installation, configuration, or troubleshooting beyond the scope of this manual.