ບໍລິສັດ Axis Communications 02621-001

ຄູ່ມືຜູ້ໃຊ້ AXIS D8208-R ສະວິດ PoE++ 8 ພອດທີ່ມີການຈັດການແບບອຸດສາຫະກຳ

ແບບ ຈຳ ລອງ: 02621-001

1. ບົດແນະນຳ

This manual provides comprehensive instructions for the installation, operation, and maintenance of the Axis Communications D8208-R Industrial 8-Port Managed PoE++ Switch. This device is designed for robust industrial environments, offering reliable network connectivity and Power over Ethernet (PoE++) capabilities for connected devices. Please read this manual thoroughly before using the product to ensure proper and safe operation.

2. ຂໍ້ມູນຄວາມປອດໄພ

ປະຕິບັດຕາມຄວາມລະມັດລະວັງດ້ານຄວາມປອດໄພຕໍ່ໄປນີ້ເພື່ອປ້ອງກັນຄວາມເສຍຫາຍຂອງຜະລິດຕະພັນແລະຮັບປະກັນຄວາມປອດໄພຂອງຜູ້ໃຊ້:

  • ແຫຼ່ງພະລັງງານ: Use only the specified power supply for this device. Ensure the power source meets the voltage ແລະຄວາມຕ້ອງການໃນປະຈຸບັນ.
  • ສະພາບແວດລ້ອມ: Install the switch in an environment that complies with its operating temperature and humidity specifications. Avoid exposure to direct sunlight, excessive heat, moisture, or corrosive substances.
  • ການລະບາຍອາກາດ: ຮັບປະກັນການລະບາຍອາກາດທີ່ພຽງພໍອ້ອມຮອບອຸປະກອນເພື່ອປ້ອງກັນຄວາມຮ້ອນເກີນໄປ. ຢ່າອຸດຕັນຊ່ອງລະບາຍອາກາດ.
  • ການຕິດຕັ້ງ: ການຕິດຕັ້ງຄວນໄດ້ຮັບການປະຕິບັດໂດຍບຸກຄະລາກອນທີ່ມີຄຸນວຸດທິຕາມລະຫັດແລະກົດລະບຽບໄຟຟ້າທ້ອງຖິ່ນ.
  • ບໍາລຸງຮັກສາ: Do not attempt to open or service the device yourself. Refer all servicing to qualified service personnel.
  • ສາຍໄຟ: Use appropriate and certified cables for all connections.

3. ເນື້ອໃນຊຸດ

Verify that all items are present in the package. If any item is missing or damaged, contact your supplier.

  • AXIS D8208-R Industrial 8-Port Managed PoE++ Switch
  • ຄູ່ມືການຕິດຕັ້ງດ່ວນ
  • Mounting Kit (e.g., DIN rail clip, screws)
  • Terminal Block Connectors (for power input)

4. ຜະລິດຕະພັນເກີນview

The AXIS D8208-R is a robust industrial switch designed for demanding applications. It features multiple Ethernet ports with Power over Ethernet capabilities and advanced management features.

4.1 ຮູບແບບແຜງດ້ານໜ້າ

ດ້ານໜ້າ view of AXIS D8208-R Industrial Switch showing ports and indicators

ຮູບທີ 1: ດ້ານໜ້າ view of the AXIS D8208-R Industrial Switch. This image displays the front panel of the switch, highlighting the various Ethernet ports, power input terminals, LED indicators, and the console port. Ports 1-4 are 1G PoE++ ports, ports 5-8 include 1G and 2.5G PoE++ capabilities, and ports 9-10 are 10G SFP+ ports.

ລາຍລະອຽດດ້ານໜ້າ view of AXIS D8208-R Industrial Switch

ຮູບທີ 2: ລາຍລະອຽດດ້ານໜ້າ view of the AXIS D8208-R Industrial Switch. This image provides a closer look at the port configuration and LED indicators. It shows the two 10G SFP+ uplink ports (9 and 10) at the bottom, the console port, and the reset button. The power input terminals are visible on the right side.

4.2 Components Description

  • ຜອດອີເທີເນັດ (1-4): 1 Gigabit Ethernet ports with PoE++ (802.3bt) support.
  • ຜອດອີເທີເນັດ (5-8): 1 Gigabit and 2.5 Gigabit Ethernet ports with PoE++ (802.3bt) support.
  • 10G Ports (9-10): 10 Gigabit SFP+ uplink ports for high-speed connections.
  • Power Input (P1, P2): Redundant power input terminals for enhanced reliability.
  • ຜອດຄອນໂຊນ: ພອດ RJ45 ສຳລັບການຄຸ້ມຄອງທ້ອງຖິ່ນ ແລະ ການຕັ້ງຄ່າຜ່ານການເຊື່ອມຕໍ່ແບບ serial.
  • ປຸ່ມຣີເຊັດ: ໃຊ້ເພື່ອຕັ້ງຄ່າອຸປະກອນຄືນໃໝ່ໃຫ້ເປັນຄ່າເລີ່ມຕົ້ນຈາກໂຮງງານ ຫຼື ປິດເປີດເຄື່ອງໃໝ່.
  • ຕົວຊີ້ວັດ LED:
    • SYS: ຕົວຊີ້ບອກສະຖານະຂອງລະບົບ.
    • P1, P2: Power input status indicators.
    • ALM: ຕົວຊີ້ບອກປຸກ.
    • RM, RC: Redundancy Management / Redundancy Control indicators.

5. ຕັ້ງຄ່າ

5.1 ການຕິດຕັ້ງ

The AXIS D8208-R is designed for DIN rail mounting.

  1. Attach the DIN rail clip (if not pre-installed) to the rear of the switch using the provided screws.
  2. Hook the top edge of the DIN rail clip onto the DIN rail.
  3. Push the bottom of the switch firmly towards the DIN rail until it clicks into place.
  4. Ensure the switch is securely fastened to the DIN rail.

5.2 ການເຊື່ອມຕໍ່ພະລັງງານ

The switch supports redundant power inputs (P1 and P2) for increased reliability.

  1. Ensure the power source is turned off before making any connections.
  2. Connect the positive (+) and negative (-) wires from your DC power supply to the corresponding terminals on the provided terminal block connector for P1.
  3. Insert the terminal block connector into the P1 power input port on the switch.
  4. (Optional) For redundant power, repeat steps 2 and 3 for the P2 power input.
  5. Once all connections are secure, turn on the power supply. The P1 and/or P2 LEDs should illuminate.

5.3 ການເຊື່ອມຕໍ່ເຄືອຂ່າຍ

Connect network devices and uplink connections.

  • Standard Devices: Connect your network devices (e.g., IP cameras, access points) to ports 1-8 using standard Ethernet cables. These ports will provide PoE++ power if the connected device supports it.
  • Uplink: For high-speed uplink to your core network, insert compatible SFP+ transceivers into ports 9 and 10, then connect fiber optic cables.

5.4 ການຕັ້ງຄ່າເບື້ອງຕົ້ນ

ສະຫຼັບສາມາດຕັ້ງຄ່າໄດ້ຜ່ານທາງ web-based interface or a command-line interface (CLI) through the console port.

  • Web ການໂຕ້ຕອບ: Connect a computer to any Ethernet port on the switch. The switch will typically obtain an IP address via DHCP or use a default static IP. Refer to the Quick Installation Guide for the default IP address and login credentials.
  • ຜອດຄອນໂຊນ: Connect a serial cable from your computer to the console port on the switch. Use a terminal emulation program (e.g., PuTTY) with the specified serial settings (e.g., 115200 baud, 8 data bits, no parity, 1 stop bit, no flow control) to access the CLI.

6. ການເຮັດວຽກ

6.1 ຕົວຊີ້ວັດ LED

Monitor the LED indicators for the operational status of the switch.

LEDສະຖານະລາຍລະອຽດ
SYSສີຂຽວ (ແຂງ)ລະບົບເຮັດວຽກເປັນປົກກະຕິ.
SYSສີຂຽວ (ກະພິບ)System is booting or performing an operation.
P1/P2ສີຂຽວ (ແຂງ)Corresponding power input is active.
ALMRed (Solid/Flashing)An alarm condition exists (e.g., power failure, port error). Check system logs.
ໄຟ LED Portສີຂຽວ (ແຂງ)ສ້າງ​ການ​ເຊື່ອມ​ຕໍ່​.
ໄຟ LED Portສີຂຽວ (ກະພິບ)ກິດຈະກຳຂໍ້ມູນ.

6.2 ການຈັດການ ແລະການຕັ້ງຄ່າ

The AXIS D8208-R is a managed switch, offering a range of configuration options for network optimization and security.

  • Web-GUI ອີງ​ໃສ່​: ເຂົ້າເຖິງສະວິດ web interface via a standard web browser to configure VLANs, QoS, port settings, PoE management, security features, and more.
  • CLI: For advanced users, the Command Line Interface provides granular control over all switch functions.
  • SNMP: The switch supports SNMP for integration with network management systems.

7. ບໍາລຸງຮັກສາ

7.1 ການທໍາຄວາມສະອາດ

To maintain optimal performance, periodically clean the exterior of the switch.

  • ໃຫ້ແນ່ໃຈວ່າໄດ້ຕັດການເຊື່ອມຕໍ່ກ່ອນທີ່ຈະທໍາຄວາມສະອາດ.
  • ໃຊ້ຜ້າປຽກອ່ອນໆເຊັດພື້ນຜິວພາຍນອກ.
  • ຢ່າໃຊ້ນໍ້າຢາລ້າງຂອງແຫຼວ ຫຼື ນໍ້າຢາສີດ, ເພາະມັນອາດຈະເຮັດໃຫ້ອຸປະກອນເສຍຫາຍໄດ້.
  • ຮັກສາຊ່ອງລະບາຍອາກາດໃຫ້ສະອາດຂອງຂີ້ຝຸ່ນແລະສິ່ງເສດເຫຼືອ.

7.2 ການອັບເດດເຟີມແວ

Regularly check the Axis Communications webເວັບໄຊທ໌ສໍາລັບການອັບເດດເຟີມແວຫຼ້າສຸດ. ການອັບເດດເຟີມແວສາມາດສະໜອງຄຸນສົມບັດໃໝ່, ການປັບປຸງປະສິດທິພາບ ແລະການປັບປຸງຄວາມປອດໄພ.

  • ດາວໂຫລດເຟີມແວທີ່ເຫມາະສົມ file from the official Axis Communications support page for your model.
  • Follow the instructions provided with the firmware update package for the correct update procedure, typically performed via the web ການໂຕ້ຕອບ.

8. ການແກ້ໄຂບັນຫາ

If you encounter issues with your AXIS D8208-R switch, refer to the following common troubleshooting steps.

  • ບໍ່ມີພະລັງງານ:
    • Check power cable connections to the switch and the power source.
    • ກວດສອບວ່າແຫຼ່ງຈ່າຍໄຟເຮັດວຽກຢ່າງຖືກຕ້ອງ ແລະ ໃຫ້ລະດັບສຽງທີ່ຖືກຕ້ອງtage.
    • Ensure the P1/P2 LEDs are illuminated.
  • ບໍ່ມີການເຊື່ອມຕໍ່ເຄືອຂ່າຍ:
    • Check Ethernet cable connections for both the switch and the connected device.
    • Verify the link/activity LEDs on the respective port are active.
    • Ensure the connected device is powered on and configured correctly.
    • Check switch configuration (VLANs, port status) via the web ການໂຕ້ຕອບຫຼື CLI.
  • ອຸປະກອນ PoE ບໍ່ເປີດ:
    • Ensure the connected device is PoE compatible and within the switch's PoE budget.
    • Check the PoE status for the port in the switch's management interface.
    • Verify the Ethernet cable is a standard Cat5e/6 or higher.
  • ການເຂົ້າເຖິງ Web Interface Fails:
    • Confirm your computer's IP address is in the same subnet as the switch, or that DHCP is functioning.
    • Try accessing the switch via the console port to verify its IP configuration.
    • ລຶບລ້າງແຄດຂອງບຼາວເຊີຂອງທ່ານ ຫຼືລອງໃຊ້ໂປຣແກຣມທ່ອງເວັບອື່ນ.
  • ປັບຄ່າໂຮງງານ: If issues persist and you need to restore default settings, press and hold the reset button for approximately 10-15 seconds until the SYS LED changes behavior, then release. Warning: This will erase all custom configurations.

9. ຂໍ້ມູນຈໍາເພາະ

ຄຸນສົມບັດລາຍລະອຽດ
ຍີ່ຫໍ້ການສື່ສານແກນ
ໝາຍເລກຕົວແບບ02621-001
ຊື່ຜະລິດຕະພັນAXIS D8208-R Industrial 8-Port Managed PoE++ Switch
ທ່າເຮືອ8 x PoE++ Ethernet (1G/2.5G), 2 x 10G SFP+
ການປ້ອນຂໍ້ມູນພະລັງງານRedundant DC power input (terminal blocks)
ນ້ໍາຫນັກລາຍການ3.37 ປອນ (ປະມານ 1.53 ກິ​ໂລ​)
ຂະໜາດແພັກເກັດ1.97 x 0.79 x 0.79 ນິ້ວ (ປະມານ 5 x 2 x 2 ຊມ)
ຜູ້ຜະລິດAXIS - ACCESS CONTROL
ວັນທີທໍາອິດທີ່ມີວັນທີ 29 ພຶດສະພາ 2024

10. ການຮັບປະກັນແລະການສະຫນັບສະຫນູນ

For detailed warranty information, technical support, and additional resources, please visit the official Axis Communications webເວັບໄຊ.

Webເວັບໄຊ: www.axis.com

Contact Axis Communications support for assistance with product installation, configuration, or troubleshooting beyond the scope of this manual.

ເອກະສານທີ່ກ່ຽວຂ້ອງ - 02621-001

ກ່ອນview ຄູ່ມືການຕັ້ງຄ່າສະວິດເຄືອຂ່າຍ Axis - ການຕັ້ງຄ່າ ແລະ ການຄຸ້ມຄອງ
ຄູ່ມືທີ່ຄົບຖ້ວນສົມບູນສຳລັບຜູ້ເບິ່ງແຍງລະບົບເຄືອຂ່າຍກ່ຽວກັບການຕັ້ງຄ່າ ແລະ ການຈັດການສະວິດເຄືອຂ່າຍ AXIS T85 ແລະ D8208-R. ກວມເອົາການຕັ້ງຄ່າ, ຄຸນສົມບັດຕ່າງໆ, ຄວາມປອດໄພ ແລະ ການແກ້ໄຂບັນຫາ.
ກ່ອນview ຄູ່ມືການຕິດຕັ້ງ AXIS High PoE Midspan ແລະ Splitters
ຄູ່ມືການຕິດຕັ້ງສຳລັບ AXIS T8123 High PoE Midspan ແລະ AXIS T8126/T8128 High PoE Splitters, ເຊິ່ງກວມເອົາການຕັ້ງຄ່າ, ສະເປັກ, ແລະ ການແກ້ໄຂບັນຫາສຳລັບໂຊລູຊັ່ນ Power over Ethernet.
ກ່ອນview ຄູ່ມືການຕິດຕັ້ງເຊັນເຊີຄຸນນະພາບອາກາດ AXIS D6310
ຄູ່ມືການຕິດຕັ້ງທີ່ຄົບຖ້ວນສຳລັບເຊັນເຊີຄຸນນະພາບອາກາດ AXIS D6310. ຮຽນຮູ້ວິທີການຕິດຕັ້ງ, ເຊື່ອມຕໍ່ ແລະ ຕັ້ງຄ່າອຸປະກອນຂອງທ່ານຢ່າງປອດໄພ ແລະ ມີປະສິດທິພາບ. ລວມທັງການປະຕິບັດຕາມກົດລະບຽບ, ຄຳແນະນຳດ້ານຄວາມປອດໄພ ແລະ ລາຍລະອຽດດ້ານເຕັກນິກ.
ກ່ອນview ຄູ່ມືການຕິດຕັ້ງ AXIS M43 Panoramic Camera Series
ຄູ່ມືການຕິດຕັ້ງນີ້ໃຫ້ຂໍ້ມູນທີ່ຈໍາເປັນສໍາລັບການຕັ້ງຄ່າ AXIS M43 Panoramic Camera Series, ລວມທັງຮຸ່ນ AXIS M4327-P ແລະ AXIS M4328-P. ມັນກວມເອົາຂັ້ນຕອນການຕິດຕັ້ງ, ຄວາມປອດໄພ, ແລະການປະຕິບັດຕາມກົດລະບຽບ.
ກ່ອນview ຄູ່ມືການໃຊ້ del usuario de cámaras tipo domo AXIS M30
Guía completa para la instalación, configuración y uso de las cámaras tipo domo AXIS M30, incluyendo detalles sobre imagen, vídeo, audio, aplicaciones y ciberseguridad.
ກ່ອນview ຄູ່ມືການຕິດຕັ້ງ AXIS TP3201-E Recessed Mount
ຄູ່ມືນີ້ໃຫ້ຄໍາແນະນໍາສໍາລັບການຕິດຕັ້ງ AXIS TP3201-E Recessed Mount, ລວມທັງຂໍ້ມູນຄວາມປອດໄພ, ການພິຈາລະນາທາງດ້ານກົດຫມາຍ, ແລະຂັ້ນຕອນການປະກອບເປັນຂັ້ນຕອນສໍາລັບຕົວແບບກ້ອງຖ່າຍຮູບ AXIS ທີ່ເຂົ້າກັນໄດ້.