ແນະນຳ
This manual provides instructions for the installation, operation, and maintenance of the Opengear CM8100 Console Server. The CM8100 series is designed to provide secure out-of-band management for network and server infrastructure, enabling remote access and control even during primary network outages.
Key features of the CM8100 Console Server include:
- 16, 32, or 48 port serial console server with Smart Out-of-Band™ capabilities.
- Support for Data Center and Enterprise Network automation with Python and Docker.
- Embedded physical security via TPM 2.0 module.
- Dual power supplies for redundancy and independent monitoring.
- Integrated environmental temperature monitoring.
ການຕິດຕັ້ງແລະການຕິດຕັ້ງ
This section guides you through the physical installation and initial setup of your CM8100 Console Server.
ການເປີດອຸປະກອນ
Carefully unpack all components from the box. Verify that all items listed in the "What's in the Box" section are present and undamaged.
ຮູບພາບ: ທາງຫນ້າ view of the Opengear CM8100 Console Server, showing the red and black chassis, Opengear logo, model number, and dual power inlets on the right side.
ການຕິດຕັ້ງ Rack
The CM8100 Console Server is designed for standard 19-inch rack installation.
- Attach the two rack ears to the sides of the console server using the provided M4 screws.
- Secure the console server into the rack using the four M5x15mm rack screws and M5mm caged nuts. Ensure the device is level and securely fastened.
ການເຊື່ອມຕໍ່ພະລັງງານ
The CM8100 features dual power supplies for redundancy.
- Connect the two A/C power cables to the power inlets on the rear of the console server.
- Connect the other ends of the power cables to independent power sources for redundancy.
- Verify that the power indicator LEDs on the front panel illuminate, indicating successful power-up.
ການເຊື່ອມຕໍ່ເຄືອຂ່າຍ
Connect the console server to your network for management access.
- Connect an Ethernet cable from your network switch to the primary network port on the console server.
- (Optional) Connect a second Ethernet cable to the secondary network port for network redundancy.
ການເຊື່ອມຕໍ່ Serial Port
Connect your managed devices (servers, network devices) to the serial ports on the CM8100.
- Identify the serial ports on the rear of the console server.
- Use appropriate serial cables (e.g., the provided CAT5 patch cable with DB9F-RJ45 rollover serial adapter) to connect your devices to the CM8100 serial ports.
- Note the port numbers for future configuration.
ຮູບພາບ: ດ້ານຫລັງ view of the Opengear CM8100 Console Server, displaying various network and serial console ports, along with dual power supply connections.
ການດໍາເນີນງານ
This section covers basic operation and initial access to the CM8100 Console Server.
ການເຂົ້າເຖິງເບື້ອງຕົ້ນ
Access the console server for initial configuration via a direct serial connection or network connection.
Serial Console Access
- Connect a computer to the console server's dedicated console port using a serial cable.
- Configure your terminal emulation software (e.g., PuTTY, Tera Term) with the following settings: 115200 baud, 8 data bits, no parity, 1 stop bit, no flow control.
- Power on the CM8100. The boot process will display on your terminal.
- Log in using the default credentials (refer to the Quick Start Guide for default username and password).
Network Access (Web ອິນເຕີເຟດ)
Once the device has an IP address (either DHCP assigned or manually configured via serial console), you can access the web ການໂຕ້ຕອບ.
- ເປີດ ກ web browser and enter the IP address of the CM8100.
- ເຂົ້າສູ່ລະບົບໂດຍໃຊ້ຂໍ້ມູນປະຈໍາຕົວຂອງທ່ານ.
- ຈາກ web interface, you can configure serial ports, network settings, user accounts, and other system parameters.
ການຈັດການອຸປະກອນທີ່ເຊື່ອມຕໍ່
The CM8100 allows you to connect to the console of your attached devices.
- Serial Console Access: ຈາກ web interface or command-line interface (CLI), select the desired serial port to establish a connection to the attached device.
- Out-of-Band Management: Utilize the Smart OOB™ features to access and manage devices even when the primary network is down.
ບໍາລຸງຮັກສາ
Regular maintenance ensures optimal performance and longevity of your CM8100 Console Server.
ອັບເດດເຟີມແວ
Periodically check the Opengear website for firmware updates. Keeping the firmware current provides new features, bug fixes, and security enhancements.
- Download the latest firmware image from the official Opengear support portal.
- Access the CM8100 web ການໂຕ້ຕອບ.
- Navigate to the firmware update section (typically under System > Firmware).
- Follow the on-screen instructions to upload and install the new firmware. Do not power off the device during the update process.
ທໍາຄວາມສະອາດ
Keep the console server clean to prevent dust buildup, which can affect cooling.
- ໃຊ້ຜ້າປຽກອ່ອນໆເຊັດດ້ານນອກຂອງອຸປະກອນ.
- ໃຫ້ແນ່ໃຈວ່າການເປີດລະບາຍອາກາດມີຄວາມຊັດເຈນຂອງສິ່ງກີດຂວາງ.
- ຢ່າໃຊ້ເຄື່ອງເຮັດຄວາມສະອາດຂອງແຫຼວໂດຍກົງໃນອຸປະກອນ.
ການພິຈາລະນາດ້ານສິ່ງແວດລ້ອມ
Ensure the operating environment meets the recommended conditions.
- Maintain proper airflow around the device.
- Keep the device within specified temperature and humidity ranges.
ການແກ້ໄຂບັນຫາ
This section provides solutions to common issues you might encounter with the CM8100 Console Server.
ບໍ່ມີພະລັງງານ
- ອາການ: Power indicator LEDs are off, device does not respond.
- ການແກ້ໄຂ: Verify that both A/C power cables are securely connected to the device and to active power outlets. Check power sources and circuit breakers.
ບໍ່ສາມາດເຂົ້າເຖິງໄດ້ Web ການໂຕ້ຕອບ
- ອາການ: Web browser cannot connect to the CM8100 IP address.
- ການແກ້ໄຂ:
- Verify the console server has power and is running.
- Confirm the network cable is properly connected to an active network port.
- Check the IP address configuration of the CM8100 (via serial console if necessary).
- Ensure your computer is on the same network or has a route to the CM8100's IP address.
- Temporarily disable any firewalls on your computer to rule out interference.
No Serial Console Connection to Managed Device
- ອາການ: Unable to establish a serial connection to a device connected to the CM8100.
- ການແກ້ໄຂ:
- Verify the serial cable connection between the CM8100 port and the managed device.
- Ensure the correct serial cable type (e.g., rollover, straight-through) is used for the specific device.
- Check the serial port configuration on the CM8100 (baud rate, data bits, parity, stop bits, flow control) matches the settings of the managed device.
- Confirm the managed device is powered on and functioning correctly.
ຂໍ້ມູນຈໍາເພາະ
| ຄຸນສົມບັດ | ລາຍລະອຽດ |
|---|---|
| ຍີ່ຫໍ້ | Opengear |
| ຊຸດ | CM8100 Console Server |
| ໝາຍເລກຕົວແບບ | CM8116 |
| ນ້ໍາຫນັກລາຍການ | 8.63 ປອນ |
| ຂະໜາດສິນຄ້າ (LxWxH) | 19.5 x 16.5 x 3.5 ນິ້ວ |
| ຜູ້ຜະລິດ | Opengear |
| ທໍາອິດທີ່ມີຢູ່ | ວັນທີ 16 ກຸມພາ 2023 |
ແມ່ນຫຍັງຢູ່ໃນກ່ອງ
The following items are included with your Opengear CM8100 Console Server:
- CM8100 Console Server
- ຊຸດຕິດຕັ້ງ Rack
- 2 x Rack Ears with Six M4 Screws
- 4 x M5mm Caged Nuts
- 4 x M5x15mm Rack Screws
- 1 x CAT5 Patch Cable 6'
- 1 x DB9F-RJ45 Rollover Serial Adapter
- 2 x A/C Power Cables
- ຄູ່ມືເລີ່ມຕົ້ນດ່ວນ
- Lighthouse Insert