1. ຜະລິດຕະພັນເກີນview
The Trane Control Limit 220F is a genuine OEM (Original Equipment Manufacturer) part designed for commercial HVAC units. This component functions as a temperature limit control, ensuring the safe operation of heating and cooling systems by preventing temperatures from exceeding a specified threshold of 220°F.
It is crucial to use genuine OEM parts for safety, reliability, and optimal performance of your Trane HVAC equipment.
1.1. ສິ່ງທີ່ຢູ່ໃນກ່ອງ
- Replacement Part (Trane Control Limit 220F)
1.2. ຄຸນລັກສະນະຂອງຜະລິດຕະພັນ
- ສ່ວນ OEM ຂອງແທ້: Ensures compatibility and reliability with Trane HVAC systems.
- ການຄວບຄຸມການຈໍາກັດອຸນຫະພູມ: Designed to activate at 220°F to prevent overheating.
- ການກໍ່ສ້າງທົນທານ: Built to withstand the demands of commercial HVAC environments.
- ການເຊື່ອມໂຍງງ່າຍດາຍ: Designed for straightforward replacement in compatible Trane units.

ຮູບ 1.1: ດ້ານຫນ້າ view of the Trane Control Limit 220F, showing the metallic disc, mounting bracket, orange wires, and white electrical connector.
2. ຂໍ້ມູນຄວາມປອດໄພ
ຄຳເຕືອນ: Always disconnect power to the HVAC unit before attempting any installation, maintenance, or repair. Failure to do so can result in serious injury or death from electrical shock.
- Installation should only be performed by qualified HVAC technicians or licensed electricians.
- ໃສ່ອຸປະກອນປ້ອງກັນສ່ວນບຸກຄົນທີ່ເຫມາະສົມ (PPE), ລວມທັງແວ່ນຕາຄວາມປອດໄພແລະຖົງມື.
- ໃຫ້ແນ່ໃຈວ່າການເຊື່ອມຕໍ່ສາຍໄຟທັງຫມົດແມ່ນປອດໄພແລະປະຕິບັດຕາມລະຫັດໄຟຟ້າທ້ອງຖິ່ນ.
- Do not bypass or modify the limit control. It is a critical safety device.
- Refer to the specific HVAC unit's service manual for detailed wiring diagrams and safety procedures.
3. ການຕິດຕັ້ງ & ການຕິດຕັ້ງ
This section provides general guidelines for installing the Trane Control Limit 220F. Always refer to the specific service manual for your Trane HVAC unit for precise installation instructions and wiring diagrams.
3.1. ເຄື່ອງມືທີ່ຕ້ອງການ
- Screwdriver set (Phillips ແລະ flathead)
- Wire strippers/cutters (if new wiring is needed)
- Multimeter (for testing continuity and voltage)
- ອຸປະກອນປ້ອງກັນສ່ວນບຸກຄົນ (PPE)
3.2. ຂັ້ນຕອນການຕິດຕັ້ງ
- ຕັດການເຊື່ອມຕໍ່ພະລັງງານ: Locate the main power switch for the HVAC unit and turn it OFF. Verify power is off using a multimeter.
- ອົງປະກອບການເຂົ້າເຖິງ: Open the access panel of the HVAC unit to locate the existing limit control.
- ສາຍໄຟເອກະສານ: Before disconnecting, take a photograph or make a diagram of the existing wiring connections to the limit control. This will aid in correct re-installation.
- ເອົາອົງປະກອບເກົ່າອອກ: Carefully disconnect the wires from the old limit control and unmount it from its position.
- ຕິດຕັ້ງອົງປະກອບໃຫມ່: Mount the new Trane Control Limit 220F in the same location as the old one. Ensure it is securely fastened.
- ເຊື່ອມຕໍ່ສາຍໄຟ: Connect the wires to the new limit control according to your documented diagram. Ensure all connections are tight and secure. The white connector should snap firmly into place.
- Secure Access Panel: ປິດ ແລະຮັບປະກັນແຜງການເຂົ້າເຖິງຂອງໜ່ວຍ HVAC.
- ຟື້ນຟູພະລັງງານ & ການທົດສອບ: Restore power to the HVAC unit. Perform system checks to ensure the unit operates correctly and the limit control functions as expected.

ຮູບທີ 3.1: ທາງເທິງ view of the Trane Control Limit 220F, showing the compact arrangement of the orange wires and the white connector, ready for installation.

ຮູບ 3.2: ຂ້າງ view of the Trane Control Limit 220F, highlighting the metallic disc and the points where the orange wires connect to the control unit.
4. ການດໍາເນີນງານ
The Trane Control Limit 220F is a safety device designed to monitor the temperature within the HVAC system. Its primary function is to open an electrical circuit if the temperature exceeds 220°F, thereby shutting down the heating element or other components to prevent damage or hazardous conditions.
- Under normal operating conditions, the limit control allows electrical current to pass through, enabling the HVAC unit to function.
- If the internal temperature of the monitored area reaches or exceeds 220°F, the bimetallic disc within the control will deform, opening the electrical contacts.
- Once the contacts open, power to the heating component (or other controlled device) is interrupted, causing the unit to shut down.
- The control typically resets automatically once the temperature drops below the limit, allowing the system to restart if the underlying issue is resolved.
Note: Frequent activation of the limit control indicates an underlying issue with the HVAC system that requires investigation by a qualified technician.
5. ບໍາລຸງຮັກສາ
The Trane Control Limit 220F is a robust component designed for long-term reliability. Regular maintenance of the overall HVAC system is recommended to ensure its proper function and longevity.
- ການກວດກາປະຈຳປີ: During routine HVAC system maintenance, have a qualified technician inspect the limit control for any signs of physical damage, corrosion, or loose connections.
- ຄວາມສະອາດ: Ensure the area around the limit control is free from dust, debris, or obstructions that could affect its temperature sensing capabilities.
- ຄວາມສົມບູນຂອງສາຍໄຟ: Check that all wiring connected to the limit control is intact, not frayed, and securely fastened.
- ການກວດສອບການທໍາງານ: While not a user-serviceable item for testing, a technician can verify its operation during system diagnostics.
Do not attempt to clean the internal components of the limit control or apply any lubricants. This can impair its function.
6. ການແກ້ໄຂບັນຫາ
If your HVAC unit is experiencing issues related to temperature control or unexpected shutdowns, the limit control may be involved. This section provides general troubleshooting steps. For complex issues, always consult a qualified HVAC technician.
| ອາການ | ສາເຫດທີ່ເປັນໄປໄດ້ | ການປະຕິບັດທີ່ແນະນໍາ |
|---|---|---|
| HVAC unit frequently shuts down unexpectedly. | Overheating due to restricted airflow, dirty filters, faulty blower, or other system issues causing high temperatures. | Check air filters and replace if dirty. Ensure vents are open. Inspect blower motor for proper operation. If issues persist, contact a technician to diagnose the root cause of overheating. |
| HVAC unit does not turn on (no heat/cooling). | Limit control is open (tripped) and not resetting, or it has failed. | Ensure power is off. Visually inspect the limit control for damage. A technician can test the continuity of the limit control. If it's open at normal temperatures, it may need replacement. |
| Unit runs continuously without reaching desired temperature. | Unlikely to be the limit control itself, but rather a heating element issue, thermostat problem, or other system component. | Consult the HVAC unit's service manual or a qualified technician for diagnosis. |
ສຳຄັນ: Do not attempt to bypass the limit control for troubleshooting. This is a critical safety device.
7. ຂໍ້ມູນຈໍາເພາະ
| ຄຸນລັກສະນະ | ມູນຄ່າ |
|---|---|
| ຊື່ຜະລິດຕະພັນ | Trane Control Limit 220F |
| ປະເພດສ່ວນ | Limit Switch / Temperature Control |
| ອຸນຫະພູມການເປີດໃຊ້ງານ | 220°F (Fixed) |
| ຜູ້ຜະລິດ | ເທຣນ |
| ASIN | B0BW541NLS |
| ຂະໜາດສິນຄ້າ | 11 x 9 x 2 ນິ້ວ (ຂະໜາດປະມານຂອງກ່ອງ) |
| ນ້ໍາຫນັກລາຍການ | 8 ounces (approximate package weight) |
| ວັນທີທີ່ມີໃຫ້ທໍາອິດ | ວັນທີ 18 ກຸມພາ 2023 |

ຮູບທີ 7.1: ມຸມ view of the Trane Control Limit 220F, illustrating its compact design and robust construction.
8. ການຮັບປະກັນແລະການສະ ໜັບ ສະ ໜູນ
As a genuine OEM part, the Trane Control Limit 220F is covered by Trane's standard warranty for replacement parts. Specific warranty terms and conditions may vary. Please retain your proof of purchase.
For technical support, warranty claims, or to locate an authorized Trane service provider, please contact Trane customer service or visit the official Trane webເວັບໄຊ:
- Trane Official Webເວັບໄຊ: www.trane.com
- ບໍລິການລູກຄ້າ: Refer to the Trane webສະຖານທີ່ສໍາລັບຂໍ້ມູນຕິດຕໍ່ພາກພື້ນ.
When contacting support, please have your product model (B0BW541NLS) and purchase date available.