ELEGRP ELEGRP-50A-125V

ELEGRP 50A 125/250V NEMA 14-50R Receptacle & 14-30P/14-50P Plugs Instruction Manual

Model: ELEGRP-50A-125V

1. ບົດແນະນຳ

This manual provides essential instructions for the safe installation, operation, and maintenance of your ELEGRP 50 Amps 125/250V NEMA 14-50R Range Oven Stove Receptacle and ELEGRP NEMA 14-30P & NEMA 14-50P 4-Prong Electric Dryer and Range Oven Stove Plugs. Please read this manual thoroughly before installation and use, and retain it for future reference.

2. ຂໍ້ມູນຄວາມປອດໄພ

ຄຳເຕືອນ: Risk of electric shock or fire. Improper installation or use can lead to serious injury or death. All electrical work should be performed by a qualified electrician and in accordance with all national and local electrical codes.

3. ຜະລິດຕະພັນເກີນview

The ELEGRP NEMA 14-50R Receptacle is a flush-mount power outlet designed for heavy-duty applications such as electric ranges, ovens, and EV chargers. The ELEGRP NEMA 14-30P and 14-50P plugs are industrial-grade, straight-blade plugs for electric dryers and ranges, featuring interchangeable blades for versatility.

3.1 Receptacle Features (NEMA 14-50R)

ELEGRP NEMA 14-50R Receptacle

Image: ELEGRP NEMA 14-50R Receptacle. This image shows the front view ຂອງ 50 Amp, 125/250V NEMA 14-50R flush mount receptacle with its distinct blade configuration and UL listing mark.

ELEGRP NEMA 14-50R Receptacle Features

Image: ELEGRP NEMA 14-50R Receptacle Features. This image highlights the heavy-duty industrial grade construction, including the galvanized steel mounting strap, durable nylon housing, and brass contacts.

3.2 Plug Features (NEMA 14-30P & 14-50P)

ELEGRP NEMA 14-50P Plug

Image: ELEGRP NEMA 14-50P Plug. This image displays the 4-prong NEMA 14-50P plug with its robust construction and brass blades.

ELEGRP Dual Function Plug

Image: ELEGRP Dual Function Plug. This image illustrates how the plug can be converted between NEMA 14-50P and 14-30P configurations by changing a blade, showing both configurations and the interchangeable blade component.

4. ຂໍ້ມູນຈໍາເພາະ

ຄຸນສົມບັດລາຍລະອຽດ
ໝາຍເລກຕົວແບບELEGRP-50A-125V
ປະເພດເຄື່ອງຮັບNO 14-50R
ປະເພດປັ.ກອິນNEMA 14-30P, NEMA 14-50P (interchangeable)
ສະບັບtage ການຈັດອັນດັບ125/250V
Ampການຈັດອັນດັບ erageReceptacle: 50 Amps; Plugs: 30 Amps (14-30P), 50 Amps (14-50P)
ການຕັ້ງຄ່າລວດ3 ເສົາ, 4 ສາຍ, ດິນ
ວັດສະດຸNylon housing, Brass contacts, Galvanized steel strap
Wire Gauge (Receptacle)#10, #8 to #4 AWG (Copper or Aluminum)
Wire Gauge (Plugs)#10 ຫາ #6 AWG
ການຢັ້ງຢືນUL ລາຍຊື່

5. ຄໍາແນະນໍາການຕິດຕັ້ງ

ສຳຄັນ: Ensure power is OFF at the main circuit breaker before beginning any installation. If you are unsure about any steps, consult a qualified electrician.

5.1 NEMA 14-50R Receptacle Installation

  1. ກະກຽມກ່ອງໄຟຟ້າ: Ensure you have a suitable electrical box (single or 2-gang style) installed in the wall.
  2. ສາຍໄຟລອກ: Carefully strip approximately 3/4 inch of insulation from the ends of the electrical wires (Black, Red, White, Green/Bare).
  3. ເຊື່ອມຕໍ່ສາຍ: Refer to the wiring diagram below. Connect the wires to the corresponding terminals on the receptacle.
    • Green Screw (Ground): Connect the Green or Bare copper wire.
    • Brass Screw 'X' (Hot): Connect the Red wire.
    • Brass Screw 'Y' (Hot): Connect the Black wire.
    • Silver Screw (Neutral): Connect the White wire.
  4. ສາຍໄຟທີ່ປອດໄພ: Tighten all terminal screws firmly to ensure good electrical contact. Tug gently on each wire to confirm it is secure.
  5. Mount Receptacle: Carefully push the wired receptacle into the electrical box. Secure it to the box using the mounting screws provided.
  6. ຕິດຕັ້ງແຜ່ນຕິດຝາ: Attach the appropriate wall plate (with a 2.15" diameter center hole) over the receptacle.
  7. ຟື້ນຟູພະລັງງານ: Once installation is complete and verified, turn the power back on at the circuit breaker.
NEMA 14-50R Receptacle Wiring Diagram

Image: NEMA 14-50R Receptacle Wiring Diagram. This diagram clearly labels the terminal identification markings for the NEMA 14-50R receptacle, showing where to connect the Green (Ground), Red (Hot X), Black (Hot Y), and White (Neutral) wires. It also indicates that terminals accept #10 to #4 AWG wire.

5.2 NEMA 14-30P / 14-50P Plug Wiring

  1. Select Blade Configuration: Determine if you need a 14-30P (30 Amp) or 14-50P (50 Amp) plug. The ELEGRP plug features an interchangeable blade. Ensure the correct blade is installed for your application.
  2. ຖອດປລັກອອກ: Unscrew and remove the outer casing of the plug to expose the terminal screws.
  3. ສາຍໄຟລອກ: Strip approximately 3/4 inch of insulation from the ends of the appliance cord wires (Black, Red, White, Green/Bare).
  4. ເຊື່ອມຕໍ່ສາຍ: Refer to the wiring diagram below. Connect the wires to the corresponding terminals.
    • Green Screw (Ground): Connect the Green or Bare copper wire.
    • Brass Screw (Hot): Connect the Black wire.
    • Brass Screw (Hot): Connect the Red wire.
    • Silver Screw (Neutral): Connect the White wire.
  5. ສາຍໄຟທີ່ປອດໄພ: Tighten all terminal screws firmly. Ensure no stray wire strands are present that could cause a short circuit.
  6. ປະກອບປລັກຄືນໃໝ່: Carefully reassemble the plug casing, ensuring all wires are neatly tucked inside and not pinched.
NEMA 14-50P Plug Wiring Diagram

Image: NEMA 14-50P Plug Wiring Diagram. This diagram shows the internal wiring of the NEMA 14-50P plug, indicating the connection points for Green (Ground), Black (Hot), Red (Hot), and White (Neutral) wires. It specifies acceptable wire gauge from #10 to #6 AWG.

6. ຄໍາແນະນໍາການດໍາເນີນງານ

Once the ELEGRP NEMA 14-50R receptacle is correctly installed and the appliance cord is wired with the appropriate ELEGRP NEMA 14-30P or 14-50P plug, operation is straightforward.

  1. ຢືນຢັນພະລັງງານ: Ensure the circuit breaker for the receptacle is in the ON position.
  2. ເຊື່ອມຕໍ່ອຸປະກອນ: Align the prongs of the appliance plug with the slots of the wall receptacle. Insert the plug firmly and completely into the receptacle.
  3. Operate Appliance: Turn on your appliance (e.g., electric range, dryer, EV charger) according to its manufacturer's instructions.
  4. Disconnect Appliance: To disconnect, grasp the plug body firmly and pull it straight out from the receptacle. Do not pull by the cord.
Appliance Plugged into Receptacle

Image: Appliance Plugged into Receptacle. This image shows a NEMA 14-50P plug connected to a wall-mounted receptacle, illustrating a typical installation for a heavy-duty appliance like a dryer or range.

7. ບໍາລຸງຮັກສາ

The ELEGRP receptacle and plugs are designed for durability and require minimal maintenance.

8. ການແກ້ໄຂບັນຫາ

ຖ້າທ່ານພົບບັນຫາ, ພິຈາລະນາຂັ້ນຕອນການແກ້ໄຂບັນຫາທົ່ວໄປຕໍ່ໄປນີ້:

ບັນຫາສາເຫດທີ່ເປັນໄປໄດ້ການແກ້ໄຂ
ບໍ່ມີພະລັງງານກັບເຄື່ອງໃຊ້Circuit breaker tripped; Loose wiring; Faulty appliance cord/plugCheck and reset circuit breaker. Turn off power and inspect wiring connections at both the receptacle and plug. Test appliance with another known working outlet if possible.
ສຽບຮູ້ສຶກວ່າງຢູ່ໃນບ່ອນຮັບWorn receptacle contacts; Incorrect plug typeEnsure the correct NEMA plug type (14-30P or 14-50P) is used. If contacts are worn, replace the receptacle.
ຄວາມຮ້ອນເກີນຫຼືມີກິ່ນຫອມOverload; Loose connections; Damaged wiring/componentsປິດໄຟຢູ່ທີ່ເບຣກເກີທັນທີ. Do not use. Inspect for damage or loose connections. Consult a qualified electrician.

9. ການຮັບປະກັນແລະການສະຫນັບສະຫນູນ

ELEGRP products are manufactured to high-quality standards. For warranty information or technical support, please visit the official ELEGRP webເວັບໄຊ ຫຼືຕິດຕໍ່ບໍລິການລູກຄ້າຂອງເຂົາເຈົ້າ. ຮັກສາໃບຮັບເງິນການຊື້ຂອງທ່ານສໍາລັບການຮ້ອງຂໍການຮັບປະກັນ.

ELEGRP Official Webເວັບໄຊ: Visit the ELEGRP Store on Amazon