1. ຜະລິດຕະພັນເກີນview
The Suntree DC Molded Case Circuit Breaker is engineered to safeguard DC electrical installations from overloads and short circuits. It incorporates both thermal and magnetic tripping mechanisms for reliable protection. Upon detecting a fault, the circuit breaker automatically interrupts the electrical circuit, preventing wire damage and reducing fire risk. This device can also be manually opened under its full rated load for electrical maintenance without sustaining damage. Designed for reversible connection, the circuit breaker can be wired in either direction and supports bidirectional current flow. Clear markings on the handle indicate the contact position (ON/OFF) at a glance. Its design facilitates easy installation on both standard DIN rails and vertical surfaces.

Figure 1: Renogy Suntree 160 Amp 2-Pole DC Circuit Breaker
2. ຂໍ້ມູນຄວາມປອດໄພ
- ກ່ອນທີ່ຈະຕິດຕັ້ງ ຫຼື ບໍລິການເບຣກເກີ້ວົງຈອນໄຟ, ໃຫ້ຖອດສາຍໄຟອອກສະເໝີ.
- Installation should be performed by qualified personnel in accordance with local electrical codes and standards.
- Ensure proper wire sizing and terminal connections to prevent overheating.
- ຫ້າມໃຊ້ເຄື່ອງຕັດວົງຈອນຖ້າມັນປະກົດວ່າເສຍຫາຍ.
- ໃສ່ອຸປະກອນປ້ອງກັນສ່ວນບຸກຄົນທີ່ເຫມາະສົມ (PPE) ເມື່ອເຮັດວຽກກັບລະບົບໄຟຟ້າ.
3. ການຕິດຕັ້ງ
3.1 ເນື້ອໃນຊຸດ
- 160A 2P DC Molded Case Circuit Breaker
- screws ການຕິດຕັ້ງ
- Insulation Barrier (2 pieces)

Figure 2: Product Dimensions and Included Components
3.2 ການຕິດຕັ້ງ
The circuit breaker supports both DIN rail and vertical surface mounting. Ensure the mounting location is dry, well-ventilated, and protected from direct sunlight and extreme temperatures.

Figure 3: Quick Installation on DIN Rail
3.3 ການເຊື່ອມຕໍ່ສາຍໄຟ
Connect the DC positive and negative cables to the corresponding terminals on the circuit breaker. The circuit breaker is designed for reversible connection and functions with bidirectional current. Ensure all connections are secure and tight. Install the provided insulation barriers between terminals for enhanced safety.

ຮູບທີ 4: ແຜນຜັງການເຊື່ອມຕໍ່
3.4 Sizing Tips for Circuit Breaker Selection
Proper sizing is crucial for effective protection.
- For controller/inverter/DC device:
- Determine the maximum continuous operating current (current = watt/voltagແລະ).
- Calculate maximum current = 1.25 x maximum continuous operating current.
- Select a circuit breaker whose rated current is greater than and closest to the calculated maximum current.
- For solar panel:
- Determine the short-circuit current.
- Calculate maximum current = Short-circuit current x 1.25 x 1.25.
- Select a circuit breaker whose rated current is greater than and closest to the calculated maximum current.

Figure 5: Circuit Breaker Sizing Guidelines
4. ການດໍາເນີນງານ
4.1 ການເປີດ/ປິດ
To switch the circuit breaker ON, push the handle to the 'ON' position. To switch it OFF, push the handle to the 'OFF' position. The handle's position clearly indicates the contact status.

Figure 6: ON/OFF Markings
4.2 ກົນໄກການປົກປ້ອງ
The circuit breaker provides protection against both overload and short-circuit conditions. In the event of an electrical fault, the breaker will automatically trip to protect the system.

Figure 7: Overload and Short-circuit Protection
5. ບໍາລຸງຮັກສາ
After the circuit breaker has tripped due to a fault, it can be reset manually. No damage occurs to the breaker itself from tripping. Regular visual inspection for any signs of wear or damage is recommended. Ensure connections remain tight.

Figure 8: Durability and Conductivity
6. ການແກ້ໄຂບັນຫາ
- Breaker trips frequently: This indicates an overload or short circuit in the system. Identify and resolve the underlying electrical issue before resetting the breaker.
- Breaker does not reset: Ensure the fault condition has been cleared. If the breaker still does not reset, it may be damaged and require replacement.
- No power after installation: Verify all wiring connections are correct and secure. Check for proper input voltage and ensure the breaker is in the 'ON' position.
7. ຂໍ້ມູນຈໍາເພາະ
| ຄຸນສົມບັດ | ຂໍ້ມູນຈໍາເພາະ |
|---|---|
| ຍີ່ຫໍ້ | Renogy |
| ການຈັດອັນດັບປັດຈຸບັນ | 160 Amps |
| ປະເພດຕົວແຍກວົງຈອນ | ມາດຕະຖານ |
| ປະເພດການຕິດຕັ້ງ | Surface Mount |
| ຈໍານວນເສົາ | 2 |
| UPC | 810009719694 |
| ຜູ້ຜະລິດ | Renogy |
| ເລກສ່ວນ | SUNDCCB160MC2P |
| ນ້ໍາຫນັກລາຍການ | 5.15 ປອນ |
| ຂະໜາດສິນຄ້າ | 7.9 x 3.5 x 5.3 ນິ້ວ |
| ວັດສະດຸ | ທອງແດງ |
| ອົງປະກອບລວມ | 160A 2P DC Molded Case Circuit Breaker, Mounting Screws, Insulation Barrier |
8. ການຮັບປະກັນແລະການສະຫນັບສະຫນູນ
Renogy offers a 1-year material and workmanship warranty for this product. For technical support or warranty claims, please visit the official Renogy webເວັບໄຊ ຫຼືຕິດຕໍ່ບໍລິການລູກຄ້າຂອງເຂົາເຈົ້າ.
ສໍາລັບຂໍ້ມູນເພີ່ມເຕີມ, ໄປຢ້ຽມຢາມ Renogy Store.