This manual provides essential information for the safe and efficient operation, setup, and maintenance of your Generac GP6500 portable generator. The GP6500 is designed to provide reliable power with PowerRush Advanced Technology, offering increased starting capacity for various applications.
ຂໍ້ມູນຄວາມປອດໄພ
Always operate the generator outdoors in a well-ventilated area, away from windows and doors, to prevent carbon monoxide poisoning. Never operate the generator indoors, including garages or sheds.
- COSense Technology: This generator is equipped with COSense Technology, which automatically shuts down the engine if hazardous carbon monoxide levels are detected.
- Low-Oil Level Shutdown: The engine will automatically shut down if the oil level drops below a safe operating threshold, protecting the engine from damage.
- ຕົວຕັດວົງຈອນ: Integrated AC circuit breakers protect the generator from overload. Reset them by pressing the button after resolving the overload condition.
ຕັ້ງຄ່າ
1. ການຫຸ້ມຫໍ່ແລະການປະກອບ
Carefully remove the generator and all components from the packaging. Assembly typically involves attaching the wheels and the easy fold-down handle. Refer to the included assembly guide for detailed steps.

ຮູບ 1: ດ້ານຫນ້າ view of the Generac GP6500 Portable Generator, showing the control panel, wheels, and handle.
2. ເພີ່ມນ້ຳມັນເຄື່ອງ
The generator is shipped without engine oil. Locate the oil fill cap/dipstick. Using the provided funnel, carefully add the recommended engine oil (typically 10W-30, a quart is often included with the generator) until it reaches the 'Full' mark on the dipstick. Do not overfill.

ຮູບ 2: ຂ້າງ view of the generator, indicating the location for oil addition.
3. ການເພີ່ມນໍ້າມັນ
Fill the large-capacity steel fuel tank with fresh, unleaded gasoline. Ensure the fuel cap is securely tightened after filling. The built-in fuel gauge allows for easy monitoring of fuel levels.
ຄໍາແນະນໍາການດໍາເນີນງານ
1. ການເລີ່ມຕົ້ນເຄື່ອງກໍາເນີດໄຟຟ້າ
- ໃຫ້ແນ່ໃຈວ່າເຄື່ອງປັ່ນໄຟຢູ່ເທິງພື້ນຜິວລະດັບຫນຶ່ງແລະການໂຫຼດໄຟຟ້າທັງຫມົດຖືກຕັດການເຊື່ອມຕໍ່.
- ໝຸນວາວນໍ້າມັນເຊື້ອໄຟໄປທີ່ຕຳແໜ່ງ 'ເປີດ'.
- Move the choke lever to the 'CHOKE' position (if starting a cold engine).
- For electric start models, press and hold the 'START' button until the engine starts. For manual start, pull the recoil starter handle firmly.
- ເມື່ອເຄື່ອງຈັກເລີ່ມຕົ້ນ, ຄ່ອຍໆຍ້າຍ choke lever ໄປຕໍາແຫນ່ງ 'RUN'.
2. ການເຊື່ອມຕໍ່ການໂຫຼດໄຟຟ້າ
Once the generator is running smoothly, you can connect your electrical devices to the appropriate outlets (120V, 240V). Do not overload the generator. The control panel features multiple outlets with protective covers.

Figure 3: Control panel of the Generac GP6500, displaying the hour meter, AC breakers, and various power outlets.
3. ການຕິດຕາມກວດກາການດຳເນີນງານ
The integrated hour meter tracks engine run time, which is crucial for scheduling maintenance intervals. Regularly check the fuel gauge and listen for any unusual engine noises.
4. ປິດເຄື່ອງກໍາເນີດໄຟຟ້າ
- ຕັດການເຊື່ອມຕໍ່ການໂຫຼດໄຟຟ້າທັງໝົດຈາກເຄື່ອງກຳເນີດ.
- ອະນຸຍາດໃຫ້ເຄື່ອງຈັກແລ່ນເປັນເວລາສອງສາມນາທີໂດຍບໍ່ມີການໂຫຼດເພື່ອໃຫ້ເຢັນລົງ.
- ຫັນປ່ຽນເຄື່ອງຈັກໄປຫາຕໍາແຫນ່ງ 'ປິດ'.
- ໝຸນວາວນໍ້າມັນເຊື້ອໄຟໄປທີ່ຕຳແໜ່ງ 'ປິດ'.
ບໍາລຸງຮັກສາ
Regular maintenance ensures the longevity and optimal performance of your generator. Always refer to the complete owner's manual for detailed maintenance schedules and procedures.
- ການປ່ຽນແປງນ້ໍາມັນ: Change the engine oil at recommended intervals, typically after the first 20 hours of operation, and then every 50-100 hours or annually, whichever comes first. Use the hour meter to track usage.
- ການກັ່ນຕອງອາກາດ: ກວດກາ ແລະເຮັດຄວາມສະອາດເຄື່ອງກອງອາກາດເປັນປະຈຳ. ປ່ຽນແທນຖ້າເສຍຫາຍ.
- ປລັກສຽບໄຟ: ກວດສອບ ແລະ ທຳຄວາມສະອາດຫົວທຽນທຸກໆປີ ຫຼື ທຸກໆ 100 ຊົ່ວໂມງ. ປ່ຽນໃໝ່ຖ້າຈຳເປັນ.
- ລະບົບນໍ້າມັນ: Use a fuel stabilizer if storing the generator for extended periods to prevent fuel degradation.
- ທໍາຄວາມສະອາດທົ່ວໄປ: ຮັກສາເຄື່ອງປັ່ນໄຟໃຫ້ສະອາດ ແລະບໍ່ມີສິ່ງເສດເຫຼືອ.
ການແກ້ໄຂບັນຫາ
If your generator experiences issues, consult the following basic troubleshooting steps. For complex problems, contact qualified service personnel.
| ບັນຫາ | ສາເຫດທີ່ເປັນໄປໄດ້ | ການແກ້ໄຂ |
|---|---|---|
| ເຄື່ອງຈັກຈະບໍ່ເລີ່ມຕົ້ນ | No fuel, low oil, choke not set, battery low (electric start) | Add fuel, add oil, adjust choke, charge battery. |
| ບໍ່ມີຜົນຜະລິດພະລັງງານ | ເບກເກີຕັດວົງຈອນ, ໂຫຼດເກີນ, ການເຊື່ອມຕໍ່ຜິດພາດ | ຕັ້ງຄ່າເຄື່ອງຕັດວົງຈອນຄືນໃໝ່, ຫຼຸດຜ່ອນການໂຫຼດ, ກວດສອບການເຊື່ອມຕໍ່. |
| ເຄື່ອງຈັກປິດໃນລະຫວ່າງການເຮັດວຽກ | Low oil, COSense activation, overload | Check oil level, move to well-ventilated area, reduce load. |
ຂໍ້ມູນຈໍາເພາະ
- ຍີ່ຫໍ້: ທົ່ວໄປ
- ຕົວແບບ: GP6500 (G0076905)
- ແລ່ນວັດtage: 6500 ວັດ
- ເລີ່ມວັດtage: 9100 ວັດ
- ປະເພດນໍ້າມັນເຊື້ອໄຟ: ນ້ຳມັນເຊື້ອໄຟ
- ປະເພດເຄື່ອງຈັກ: 4 Stroke, OHV
- ການຍ້າຍເຄື່ອງຈັກ: 389 ຊັງຕີແມັດກ້ອນ
- ປະລິມານຖັງນໍ້າມັນ: 5 ກາລອນ
- ລະບົບໄຟໄຫມ້: ເລີ່ມໄຟຟ້າ
- ປລັກສຽບໄຟທັງໝົດ: 3 (various 120V and 120V/240V options)
- ຂະໜາດ (LxWxH): 28.3 x 27 x 28 ນິ້ວ
- ນ້ໍາຫນັກລາຍການ: 195.6 ປອນ
- ຄຸນນະສົມບັດພິເສດ: PowerRush Advanced Technology, COSense Technology, Low-Oil Shutdown, Hour Meter, Heavy-Duty Wheels, Fold-Down Handle
ການຮັບປະກັນແລະການສະຫນັບສະຫນູນ
For warranty information, technical support, or service inquiries, please refer to the warranty documentation included with your generator or visit the official Generac website. You may also contact customer support at the number provided in your product documentation.