ແນະນຳ
This manual provides detailed instructions for the proper use and maintenance of your LaMotte 1742 Chlorine Meter ORP Tracer Pocketester. This pocket-sized instrument is designed for accurate measurement of total chlorine and ORP (Oxidation-Reduction Potential) using interchangeable flat surface sensors. Please read this manual thoroughly before operating the device to ensure optimal performance and longevity.
ສິນຄ້າເກີນview

ຮູບທີ 1: LaMotte 1742 Chlorine Meter ORP Tracer Pocketester. This image displays the compact, handheld meter with its digital display showing a reading of 8.77 and a temperature of 25.0 degrees. Below the display are buttons for MODE, CAL, and ON/OFF, along with the LaMotte brand logo. The sensor probe is visible at the bottom.
The LaMotte 1742 is a versatile, portable meter featuring a digital display, intuitive controls, and a replaceable sensor. It is engineered for high resolution measurements and includes automatic self-calibration capabilities for reliable results.
ຕັ້ງຄ່າ
- ການຕິດຕັ້ງຫມໍ້ໄຟ:
Locate the battery compartment cover, typically on the rear or top of the device. Open the cover and insert the required batteries. Ensure correct polarity. Close the compartment securely.
- Sensor Attachment:
The meter uses interchangeable flat surface sensors. Carefully align the sensor with the connector port at the bottom of the meter and twist or push until it is firmly seated. Avoid excessive force.
- ການກະກຽມເບື້ອງຕົ້ນ:
Before first use, or after prolonged storage, condition the sensor according to the specific sensor's instructions (e.g., soaking in a conditioning solution or distilled water for a specified period). This ensures accurate readings.
ຄໍາແນະນໍາການດໍາເນີນງານ
- ເປີດ/ປິດ:
ກົດ ເປີດ/ປິດ button to power on the meter. The display will illuminate and show a brief self-test. To power off, press and hold the ເປີດ/ປິດ ກົດປຸ່ມຈົນກ່ວາຈໍສະແດງຜົນປິດ.
- ການເລືອກໂໝດ:
ກົດ ໂໝດ button to cycle through available measurement parameters (e.g., Total Chlorine, ORP). The selected mode will be indicated on the display.
- ການປັບທຽບ:
For accurate measurements, regular calibration is essential. Press the CAL button to enter calibration mode. Follow the on-screen prompts to calibrate using appropriate calibration solutions for the selected parameter. The meter features automatic self-calibration.
- ການວັດແທກ:
Immerse the sensor tip into the sample solution, ensuring the flat surface is fully submerged. Gently stir the meter in the solution to remove air bubbles. Allow the reading to stabilize on the display before recording the measurement.
- ການອ່ານຈໍສະແດງຜົນ:
The digital display shows the primary measurement (e.g., chlorine concentration in ppm or ORP in mV) and often includes a secondary reading such as temperature.
ບໍາລຸງຮັກສາ
- ການອະນາໄມເຊັນເຊີ:
After each use, rinse the sensor thoroughly with distilled or deionized water to prevent sample residue buildup. For stubborn deposits, refer to the sensor-specific cleaning instructions, which may involve mild detergents or specialized cleaning solutions.
- Sensor Storage:
When not in use, store the sensor in its protective cap, ideally with a small amount of appropriate storage solution. Do not allow the sensor to dry out completely.
- ການປ່ຽນແບັດເຕີຣີ:
Replace batteries when the low battery indicator appears on the display or when the meter fails to power on. Always use fresh batteries of the specified type.
- ການດູແລທົ່ວໄປ:
Keep the meter clean and dry. Avoid exposing it to extreme temperatures, direct sunlight, or corrosive chemicals. Do not drop or subject the meter to severe impact.
ການແກ້ໄຂບັນຫາ
| ບັນຫາ | ສາເຫດທີ່ເປັນໄປໄດ້ | ການແກ້ໄຂ |
|---|---|---|
| ເຄື່ອງວັດແທກບໍ່ເປີດ. | ແບັດເຕີຣີຕາຍ ຫຼື ຕິດຕັ້ງບໍ່ຖືກຕ້ອງ. | ປ່ຽນແບັດເຕີລີ, ຮັບປະກັນການຂົ້ວທີ່ຖືກຕ້ອງ. |
| ການອ່ານບໍ່ຖືກຕ້ອງຫຼືບໍ່ຄົງທີ່. |
|
|
| ຈໍສະແດງຜົນສະແດງ "Err" ຫຼືລະຫັດຄວາມຜິດພາດ. | General system error or sensor issue. | Power off and restart the meter. If the error persists, refer to specific error codes in the full product manual (if available) or contact customer support. |
ຂໍ້ມູນຈໍາເພາະ
- ຕົວແບບ: ລາມອດ 1742
- ຕົວກໍານົດການວັດແທກ: Total Chlorine, ORP (Oxidation-Reduction Potential)
- ປະເພດເຊັນເຊີ: Interchangeable flat surface sensors
- ຄວາມລະອຽດ: High resolution, typically 1 mV for ORP measurements.
- ການປັບທຽບ: ການປັບຕົວເອງອັດຕະໂນມັດ
- ຈໍສະແດງຜົນ: Digital LCD with primary and secondary readings (e.g., measurement and temperature)
- ແຫຼ່ງພະລັງງານ: Batteries (type specified on device or packaging).
- ຄຸນສົມບັດ: Pocket-sized, portable design
ຂໍ້ມູນສະຫນັບສະຫນູນ
For further assistance, technical support, or information regarding warranty, please visit the official LaMotte website or contact their customer service department. Contact details are typically found on the manufacturer's packaging or webເວັບໄຊ.
ໝາຍເຫດ: ຂໍ້ກຳນົດ ແລະ ເງື່ອນໄຂການຮັບປະກັນສະເພາະອາດແຕກຕ່າງກັນໄປຕາມພາກພື້ນ ແລະ ວັນທີຊື້. ກະລຸນາເກັບຫຼັກຖານການຊື້ຂອງທ່ານໄວ້.





