Beckett BK171UL

Beckett BK171UL Condensate Pump with Safety Switch User Manual

Model: BK171UL

1. ບົດແນະນຳ

This manual provides detailed instructions for the installation, operation, and maintenance of the Beckett BK171UL Condensate Pump. This pump is designed for automatic removal of condensate from HVAC equipment, including air conditioners, furnaces, boilers, dehumidifiers, and high-efficiency oil or gas-fired furnaces. It is suitable for condensate water temperatures up to 150°F and acidic condensate.

Beckett BK171UL Condensate Pump

Image 1.1: Beckett BK171UL Condensate Pump, front view.

2. ຂໍ້ມູນຄວາມປອດໄພ

ຄຳເຕືອນ: ຄວາມສ່ຽງຕໍ່ການເກີດໄຟຟ້າຊັອດ. ຕັດການເຊື່ອມຕໍ່ໄຟຟ້າກ່ອນທີ່ຈະໃຫ້ບໍລິການ.

  • ອ່ານຄໍາແນະນໍາທັງຫມົດຢ່າງລະອຽດກ່ອນທີ່ຈະຕິດຕັ້ງແລະການດໍາເນີນງານ.
  • ໃຫ້ແນ່ໃຈວ່າການສະຫນອງພະລັງງານກົງກັບ vol ຂອງປັ໊ມtage (115V).
  • ຢ່າໃຊ້ປັ໊ມດ້ວຍສາຍໄຟຫຼືປລັກທີ່ເສຍຫາຍ.
  • ຢ່າຈຸ່ມປັ໊ມລົງໃນນໍ້າ.
  • This pump is designed for indoor use only.
  • ຮັກສາມືໃຫ້ຊັດເຈນຂອງພາກສ່ວນການເຄື່ອນຍ້າຍໃນລະຫວ່າງການປະຕິບັດງານ.
  • ຮັບປະກັນການລົງພື້ນດິນທີ່ຖືກຕ້ອງຕາມລະຫັດໄຟຟ້າທ້ອງຖິ່ນ.
  • The pump is equipped with a safety switch. Ensure it is correctly wired to prevent overflow.

3. ເນື້ອໃນຊຸດ

ກວດ​ສອບ​ວ່າ​ອົງ​ປະ​ກອບ​ທັງ​ຫມົດ​ແມ່ນ​ມີ​ຢູ່​ກ່ອນ​ທີ່​ຈະ​ເລີ່ມ​ຕົ້ນ​ການ​ຕິດ​ຕັ້ງ​:

  • Beckett BK171UL Condensate Pump unit
  • 3/8" O.D. barbed check valve
  • Integrated 6-ft grounded power cord
  • ຄູ່ມືແນະ ນຳ (ເອກະສານນີ້)
ລະເບີດ view of Beckett BK171UL Condensate Pump components

ຮູບພາບ 3.1: ລະເບີດ view showing pump components including cover, check valve, motor, fan, automatic switches, lift-to-test tab, bullseye level, floats, impeller, multi-slot metal mount tabs, 6 ft. grounded power cord, and collection tank.

4. ການຕິດຕັ້ງແລະການຕິດຕັ້ງ

4.1 ການຕິດຕັ້ງປັ໊ມ

The pump features stainless steel multi-slot mounting tabs for secure installation. Ensure the pump is placed on a level surface. Use the integrated bullseye level on the lid to confirm proper horizontal alignment.

Beckett BK171UL Condensate Pump installation features

Image 4.1: Close-up of pump showing bullseye level, twist lock check valve, and lift-to-test tab for easy installation and maintenance.

4.2 Condensate Inlet Connections

The pump is equipped with four 1-1/8-inch diameter inlet holes for connecting condensate drain lines from your HVAC equipment. Connect the drain line(s) to any available inlet(s).

4.3 Discharge Line Connection

Connect a 3/8" I.D. vinyl tubing (not included) to the 3/8" O.D. barbed check valve. The check valve twists to lock into place on the pump, preventing backflow of discharged water. Route the discharge line to an appropriate drain, ensuring it has a continuous downward slope and is free from kinks or obstructions. The pump can lift water up to 17 feet vertically.

4.4 ການເຊື່ອມຕໍ່ໄຟຟ້າ

Plug the 6-ft grounded power cord into a standard 115V electrical outlet. Ensure the outlet is properly grounded and protected by a ground fault circuit interrupter (GFCI) if required by local codes.

4.5 Safety Switch Wiring

The integrated safety switch is designed to shut down the HVAC equipment or trigger an alarm in case of a pump malfunction or high water level, preventing overflow. Consult your HVAC equipment manual for proper wiring of the safety switch. Typically, the safety switch wires are connected in series with the low-voltage thermostat circuit of the HVAC unit.

5. ການດໍາເນີນງານ

5.1 Automatic On/Off Operation

The Beckett BK171UL pump operates automatically. When condensate water in the collection tank reaches a predetermined level, the pump will activate, remove the water, and then shut off once the water level drops. This automatic cycle ensures efficient condensate removal without constant monitoring.

Beckett BK171UL Condensate Pump performance chart

Image 5.1: Diagram illustrating automatic ON/OFF operation and average performance at various lift heights (e.g., 95 GPH at 5 ft lift, 64 GPH at 10 ft lift, 17 ft shut-off).

5.2 Lift-to-Test Function

A "lift-to-test" tab is provided on the pump lid. Lifting this tab manually raises the float, simulating a high water level and activating the pump. This feature allows for quick testing of the pump's functionality and can also be used to drain the tank for servicing.

6. ບໍາລຸງຮັກສາ

Regular maintenance ensures optimal performance and extends the life of your condensate pump.

  • ການກວດກາປະຈໍາເດືອນ: Visually inspect the pump, inlet, and discharge lines for any blockages, leaks, or damage. Ensure the discharge line is free of kinks.
  • ການເຮັດຄວາມສະອາດປະຈຳໄຕມາດ:
    1. Disconnect power to the pump and the HVAC unit.
    2. Use the lift-to-test tab to drain the tank, or manually remove any remaining water.
    3. Carefully remove the pump cover.
    4. Clean the collection tank, floats, and impeller area to remove any sludge, debris, or mineral deposits. A mild detergent and soft brush can be used.
    5. ລ້າງສ່ວນປະກອບທັງໝົດຢ່າງລະອຽດດ້ວຍນ້ຳສະອາດ.
    6. Reassemble the pump, ensuring the cover is securely in place.
    7. Reconnect power and test the pump using the lift-to-test tab.
  • ສາຍລະບາຍນ້ຳ: Periodically check the discharge line for algae or mineral buildup, especially if the pump is handling acidic condensate. Clean or replace the tubing as necessary.

7. ການແກ້ໄຂບັນຫາ

ບັນຫາສາເຫດທີ່ເປັນໄປໄດ້ການແກ້ໄຂ
ປໍ້າບໍ່ແລ່ນບໍ່ມີພະລັງງານກັບປັ໊ມCheck power cord connection, circuit breaker, and GFCI.
Float switch stuck or obstructedDisconnect power, remove cover, clean floats and tank.
Pump runs but does not discharge waterDischarge line clogged or kinkedInspect and clear the discharge line. Ensure no kinks.
Check valve obstructedDisconnect power, remove and clean the check valve.
impeller ອຸດຕັນDisconnect power, remove cover, clean impeller area.
Pump ແລ່ນຢ່າງຕໍ່ເນື່ອງFloat switch stuck in "on" positionDisconnect power, remove cover, clean floats and tank.
Leak in discharge line or check valveInspect all connections and the discharge line for leaks. Tighten or replace as needed.
ປັມມີສຽງດັງDebris in impeller or motorDisconnect power, remove cover, clean impeller area.
Pump not levelAdjust pump placement using the bullseye level.

8. ຂໍ້ມູນຈໍາເພາະ

  • ຕົວແບບ: BK171UL
  • ສະບັບtage: 115V
  • Maximum Lift: 17 ຟຸດ
  • ອັດຕາການໄຫຼ: 112 GPH @ 1 ft lift
  • Ampອາຍຸ: 1.1 Amps
  • ວັດtage: 60 ວັດ
  • ຄວາມຖີ່: 60 HZ
  • Collection Tank Capacity: 2.5 Quarts
  • ການເຊື່ອມຕໍ່ອອກ: 3/8" O.D. barbed check valve
  • ການເຊື່ອມຕໍ່ຂາເຂົ້າ: Four 1-1/8" diameter holes
  • ສາຍໄຟ: 6 ft grounded with plug
  • Maximum Condensate Water Temperature: 150°F
  • ວັດສະດຸ: Acrylonitrile Butadiene Styrene (ABS), ພາດສະຕິກ
  • ຂະໜາດ (L x W x H): 11.2" x 5.2" x 6.6"
  • ນ້ໍາຫນັກລາຍການ: 3.7 ປອນ
  • ຄຸນນະສົມບັດຄວາມປອດໄພ: Integrated safety switch, Thermally protected motor
  • ການຢັ້ງຢືນ: UL/cUL listed in U.S./Canada
Beckett BK171UL Condensate Pump dimensions

Image 8.1: Dimensions of the Beckett BK171UL Condensate Pump.

9. ການຮັບປະກັນແລະການສະຫນັບສະຫນູນ

The Beckett BK171UL Condensate Pump comes with a ການຮັບປະກັນຜູ້ຜະລິດ 3 ປີ. For warranty claims, technical assistance, or replacement parts, please contact Beckett Corporation customer support. Keep your purchase receipt as proof of purchase.

For further assistance, please refer to the official Beckett Corporation webເວັບໄຊ ຫຼືຕິດຕໍ່ພະແນກບໍລິການລູກຄ້າຂອງເຂົາເຈົ້າ.

ເອກະສານທີ່ກ່ຽວຂ້ອງ - BK171UL

ກ່ອນview ປໍ້າຄວບຄຸມຄວາມເຢັນອັດຕະໂນມັດ Beckett CB22: ຄູ່ມືການຕິດຕັ້ງ, ການໃຊ້ງານ ແລະ ຄວາມປອດໄພ
ຄູ່ມືການເປັນເຈົ້າຂອງທີ່ສົມບູນແບບສໍາລັບຫນ່ວຍ Condensate ອັດຕະໂນມັດ Beckett CB22. ປະກອບມີຄໍາແນະນໍາຢ່າງລະອຽດສໍາລັບການຕິດຕັ້ງ, ການດໍາເນີນງານທີ່ປອດໄພ, ສາຍໄຟ, ການບໍາລຸງຮັກສາ, ການແກ້ໄຂບັນຫາ, ແລະຂໍ້ມູນການຮັບປະກັນຈໍາກັດ.
ກ່ອນview Beckett BK17/BK22 Condensate Removal Pump Installation and Maintenance Guide
This guide provides detailed installation, maintenance, and safety instructions for Beckett BK17 and BK22 condensate removal pumps, including warranty information and performance specifications.
ກ່ອນview Beckett Automatic Condensate Removal Pump Installation and Operation Manual
This manual provides comprehensive installation, operation, wiring, testing, and troubleshooting guidance for Beckett Automatic Condensate Removal Pumps, including models CL201UL, CL202UL, CL202ULHT, and CL202CE. It details warranty information and maintenance procedures.
ກ່ອນview Beckett AquaSmart 7600 Boiler Control Quick Reference Guide
A concise quick reference guide for the Beckett AquaSmart 7600 Series boiler control, covering technical specifications, installation, basic programming, and wiring diagrams, along with warranty information.
ກ່ອນview Beckett PowerLight 24Vdc Igniter Installation Instructions
Comprehensive installation guide for the Beckett PowerLight 24Vdc Igniter. This document provides essential application information, detailed specifications, critical safety warnings, and step-by-step instructions for models 5272001U, 5272002U, and 5272005U, ensuring proper setup for oil burner systems.
ກ່ອນview Beckett AquaSmart Model 7600 Advanced Boiler ຄູ່ມືການຕິດຕັ້ງແລະການດໍາເນີນງານ
ຄູ່ມືທີ່ສົມບູນແບບສໍາລັບລະບົບການຄວບຄຸມຫມໍ້ຫຸງຕົ້ມ Beckett AquaSmart Model 7600, ກວມເອົາການຕິດຕັ້ງ, ສາຍໄຟ, ການຂຽນໂປລແກລມ, ຄຸນນະສົມບັດເຊັ່ນ: HeatManager™, ແລະການແກ້ໄຂບັນຫາສໍາລັບການນໍາໃຊ້ທີ່ຢູ່ອາໄສແລະການຄ້າແສງສະຫວ່າງ.