Simplex 4006-9101

ຄູ່ມືຜູ້ໃຊ້ແຜງຄວບຄຸມສັນຍານເຕືອນໄຟໄໝ້ມາດຕະຖານ Simplex 4006-9101

Model: 4006-9101 (Item Model Number: 400 9101)

ແນະນຳ

This manual provides comprehensive instructions for the installation, operation, and maintenance of the Simplex 4006-9101 Standard Fire Alarm Control Panel. Designed for areas requiring five to ten initiating zones, this panel offers flexible initiating circuit monitoring, extensive programmable control capabilities, and an LCD for annunciated circuit-specific 20-character custom labels. Proper understanding and adherence to these instructions are crucial for the safe and effective functioning of the fire alarm system.

ສິນຄ້າເກີນview

ດ້ານໜ້າ view of the Simplex 4006-9101 Fire Alarm Control Panel, a red rectangular unit with a central display and control buttons.

The Simplex 4006-9101 is a robust fire alarm control panel housed in a distinctive red enclosure. It features a central display and an array of control buttons for system management. This panel is designed for professional hard-wired installations and includes essential components for a comprehensive fire safety system.

ຄຸນ​ນະ​ສົມ​ບັດ​ທີ່​ສໍາ​ຄັນ​:

  • 5 Class B Initiating Device Circuits (IDCs)
  • 2 Class B/Class A Notification Appliance Circuits (NACs)
  • 3 Ampere power supply with integrated battery charger
  • On-board Digital Alarm Communicator Transmitter (DACT)
  • Operates on 120/240 VAC, 50/60 Hz (auto-selecting)
  • LCD annunciated circuit-specific 20 character custom labels

ພາຍໃນ view of the Simplex 4006-9101 Fire Alarm Control Panel with the door open, revealing the main circuit board, wiring terminals, and internal documentation.

The interior of the control panel is meticulously organized, featuring the main circuit board, clearly labeled wiring terminals for various circuits (IDCs, NACs, power), and internal documentation including emergency operation procedures and wiring diagrams. This design facilitates professional installation and maintenance.

ການຕິດຕັ້ງແລະການຕິດຕັ້ງ

The Simplex 4006-9101 Fire Alarm Control Panel requires professional hard-wired installation. It is crucial that installation is performed by qualified personnel in accordance with all local and national electrical and fire safety codes.

ອົງປະກອບລວມ

ສາຍໄຟ ແລະການເຊື່ອມຕໍ່

Close-up of the internal wiring terminals and circuit board of the Simplex 4006-9101 Fire Alarm Control Panel, showing IDC, NAC, and power connections.

Refer to the detailed wiring diagrams provided within the panel's internal documentation and the separate installation guide for precise connection instructions. Ensure all power connections (120/240 VAC) are made correctly and safely. Connect initiating devices (smoke detectors, pull stations) to the IDC terminals and notification appliances (horns, strobes) to the NAC terminals.

A wiring harness with multiple colored wires and connectors, typically used for internal connections within the control panel.

The provided wiring harness facilitates specific internal connections. Ensure these are securely attached according to the installation diagrams.

ການສະຫນອງພະລັງງານແລະຫມໍ້ໄຟ

The panel includes a 3 Ampere power supply with a battery charger. Connect the primary AC power source (120/240 VAC, 50/60 Hz) to the designated terminals. Install backup batteries (not typically included with the panel, refer to specifications for type and capacity) to ensure continuous operation during power outages.

ປະຕິບັດການແຜງຄວບຄຸມ

The Simplex 4006-9101 features an intuitive control interface with an LCD display and tactile buttons. Access to certain functions may require the use of the provided key.

Interior of the Simplex 4006-9101 Fire Alarm Control Panel door, showing emergency operation procedures and a diagram of the control panel buttons.

The inside of the panel door provides a quick reference guide for emergency operation procedures and a layout of the control buttons. This includes instructions on how to acknowledge alarms, silence signals, and reset the system.

ການດໍາເນີນງານພື້ນຖານ

A small brass key with the letter 'B' stamped on it, next to a black cylindrical keyhole cover.

The provided key is used to access the control panel's internal components and may be required to enable certain operational modes or to reset the system after specific events. Keep this key in a secure, accessible location.

ບໍາລຸງຮັກສາ

Regular maintenance is essential to ensure the reliable operation of your Simplex 4006-9101 Fire Alarm Control Panel. All maintenance procedures should be performed by qualified fire alarm technicians.

ການກວດສອບປົກກະຕິ

ທໍາຄວາມສະອາດ

Keep the exterior of the control panel clean using a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure ventilation openings are free from dust and debris.

ການແກ້ໄຂບັນຫາ

This section provides guidance for common issues. For complex problems or persistent trouble conditions, contact a qualified fire alarm technician.

ບັນຫາສາເຫດທີ່ເປັນໄປໄດ້ການແກ້ໄຂ
Panel displays "TROUBLE"Open circuit, ground fault, or device malfunction.Check the LCD for specific trouble messages. Inspect wiring for damage. Contact technician for diagnosis.
Alarm sounds continuously after resetAlarm condition still present or device not reset.Ensure the cause of the alarm (e.g., smoke) is cleared. Manually reset any activated devices (e.g., pull station).
No power to panelAC power loss or battery issue.Check AC power supply. Verify battery connections and charge. Replace batteries if necessary.
ປຸ່ມກົດບໍ່ຕອບສະໜອງຂໍ້ຜິດພາດຂອງຊອບແວ ຫຼື ບັນຫາຮາດແວຊົ່ວຄາວ.Try a system reset (if possible). If problem persists, contact technician.

ຂໍ້ມູນຈໍາເພາະ

ຄຸນ​ລັກ​ສະ​ນະລາຍລະອຽດ
ຜູ້ຜະລິດງ່າຍດາຍ
ເລກສ່ວນ4006-9101
ໝາຍເລກຕົວແບບ400 9101
ສີສີແດງ
ແຫຼ່ງພະລັງງານBattery Powered (with AC input)
ວິທີການຕິດຕັ້ງແບບມືອາຊີບ
ຈໍານວນຊຸດລາຍການ1
ອົງປະກອບລວມSmoke Detector, Pull Station, Horn/Strobe (as compatible devices)
ເຕັກໂນໂລຊີການເຊື່ອມຕໍ່ມີສາຍ
ປະເພດ AlertMotion Only (Note: This might be a generic category, actual alerts are fire/trouble)
ວິທີການຄວບຄຸມTouch (via keypad)
ຈຳນວນຫົວໜ່ວຍ1.0 ນັບ
Initiating Device Circuits (IDCs)5 ຊັ້ນ B
ວົງຈອນອຸປະກອນການແຈ້ງເຕືອນ (NACs)2 Class B/Class A
ການສະຫນອງພະລັງງານ3 A with battery charger
ສະບັບtage120/240 VAC, 50/60 Hz (autoselect)
Digital Alarm Communicator Transmitter (DACT)ຢູ່ເທິງເຮືອ

ຂໍ້ມູນການຮັບປະກັນ

The Simplex 4006-9101 Standard Fire Alarm Control Panel comes with a ຮັບປະກັນ 12 ເດືອນ from the date of purchase. This warranty covers defects in materials and workmanship under normal use. For warranty claims or detailed terms and conditions, please refer to the official Simplex warranty documentation or contact Simplex customer support.

ສະຫນັບສະຫນູນແລະຕິດຕໍ່

For technical assistance, service, or further information regarding your Simplex 4006-9101 Fire Alarm Control Panel, please contact Simplex customer support or a certified fire alarm system professional.

ເອກະສານທີ່ກ່ຽວຂ້ອງ - 4006-9101

ກ່ອນview Simplex 4006 Series LifeAlarm Fire Alarm Control Panels: Features, Specifications, and Operation
Comprehensive guide to the Simplex 4006 Series LifeAlarm Fire Alarm Control Panels, detailing features, specifications, product selection, operational modes, and installation references.
ກ່ອນview ຄູ່ມືການຕິດຕັ້ງ Simplex 4008/4006-9801 ແຫຼ່ງຈ່າຍໄຟຂະຫຍາຍ (EPS)
ຄຳແນະນຳໃນການຕິດຕັ້ງສຳລັບແຫຼ່ງຈ່າຍໄຟຂະຫຍາຍ (EPS) Simplex 4008/4006-9801, ລາຍລະອຽດການຕິດຕັ້ງ, ການເຊື່ອມຕໍ່ແຜງ, ສາຍໄຟ NAC, ພະລັງງານຊ່ວຍ, ແລະ ການຈັດອັນດັບ NAC ສຳລັບລະບົບເຕືອນໄພໄຟໄໝ້.
ກ່ອນview ແຜງຄວບຄຸມລະບົບເຕືອນໄພໄຟໄໝ້ Simplex 4005 Series LifeAlarm - ຄູ່ມືດ້ານວິຊາການ
ສຳຫຼວດຄຸນສົມບັດ, ສະເປັກ ແລະ ການນຳໃຊ້ຂອງແຜງຄວບຄຸມລະບົບເຕືອນໄພໄຟໄໝ້ Simplex 4005 Series LifeAlarm. ເອກະສານສະບັບນີ້ໃຫ້ຂໍ້ມູນລະອຽດສຳລັບຜູ້ເຊື່ອມໂຍງລະບົບ ແລະ ຜູ້ຈັດການສະຖານທີ່.
ກ່ອນview Simplex 4907-9101 NEWS™ Receiver: ການຕິດຕັ້ງ, ການຂຽນໂປຼແກຼມ, ແລະຄໍາແນະນໍາການດໍາເນີນງານ
This manual provides comprehensive installation, programming, and operating instructions for the Simplex 4907-9101 NEWS™ Receiver. This system is a public emergency warning receiver compatible with the 4100U Fire Alarm Control Panel, designed for alerting building complexes of emergency situations via EAS and SAME messages.
ກ່ອນview ຄຳແນະນຳໃນການຕິດຕັ້ງ ZAM ສຳລັບຈໍ Simplex 4090-9101, 4090-9106
ຄຳແນະນຳການຕິດຕັ້ງສຳລັບໂມດູນອະແດບເຕີເຂດຈໍພາບ (ZAMs) Simplex 4090-9101 ແລະ 4090-9106. ກວມເອົາການຕິດຕັ້ງກົນຈັກ, ການຕັ້ງທີ່ຢູ່ຜ່ານສະວິດ DIP, ແລະການເຊື່ອມຕໍ່ໄຟຟ້າສຳລັບລະບົບ IDNet ແລະ MAPNET II.
ກ່ອນview ແຜງຄວບຄຸມສັນຍານເຕືອນໄຟ Simplex 4004: ຄຳແນະນຳໃນການຕິດຕັ້ງ ແລະ ການນຳໃຊ້
ຄູ່ມືທີ່ຄົບຖ້ວນສົມບູນສຳລັບການຕິດຕັ້ງ, ການດໍາເນີນງານ, ແລະ ການຂຽນໂປຣແກຣມແຜງຄວບຄຸມສັນຍານເຕືອນໄຟໄໝ້ Simplex 4004 (FACP), ລວມທັງລະບົບview, ຄວາມຕ້ອງການ, ສາຍໄຟ, ລາຍລະອຽດໂມດູນ, ແລະ ການແກ້ໄຂບັນຫາ.