APOLLO 69ELF114TWG

Apollo 3/4" Bronze Double Union Threaded Water Pressure Regulator with Gauge Instruction Manual

Model: 69ELF114TWG

1. ຜະລິດຕະພັນເກີນview

The Apollo 3/4" Bronze Double Union Threaded Water Pressure Regulator with Gauge (Model 69ELF114TWG) is designed to reduce incoming water pressure to a safe and consistent level for residential and commercial plumbing systems. This unit features a compact design, lead-free bronze construction, and an integrated internal bypass mechanism. It includes a color-coded gauge for easy pressure monitoring and adjustment.

Apollo 3/4 inch Bronze Water Pressure Regulator with Gauge

Figure 1: Apollo 3/4" Bronze Double Union Threaded Water Pressure Regulator with Gauge. This image shows the regulator with its integrated pressure gauge and yellow adjustment handle.

2. ຂໍ້ມູນຄວາມປອດໄພ

3. ເນື້ອໃນຊຸດ

ກວດ​ສອບ​ວ່າ​ອົງ​ປະ​ກອບ​ທັງ​ຫມົດ​ແມ່ນ​ມີ​ຢູ່​ກ່ອນ​ທີ່​ຈະ​ເລີ່ມ​ຕົ້ນ​ການ​ຕິດ​ຕັ້ງ​:

4. ການຕິດຕັ້ງ

This regulator features a double union PEX-A (cold expansion) barb design for simplified installation in PEX-A piping systems. Ensure the regulator is installed in the correct flow direction, indicated by an arrow on the body.

  1. ກະກຽມສະຖານທີ່ຕິດຕັ້ງ: Turn off the main water supply. Drain the water lines to relieve pressure. Select a suitable location for the regulator, typically after the main shut-off valve and before any branch lines.
  2. Cut and Prepare PEX-A Piping: Cut the PEX-A pipe to the required length, ensuring clean, square cuts. Prepare the pipe ends for cold expansion connections according to PEX-A system manufacturer guidelines.
  3. Connect the Regulator:
    • Apply appropriate thread sealant (e.g., Teflon tape or pipe dope) to the male threads of the PEX-A fittings.
    • Thread the PEX-A fittings onto the double union ends of the regulator. Ensure the flow arrow on the regulator body points in the direction of water flow into the building.
    • Tighten the union nuts securely, but do not overtighten.
    • Perform cold expansion connections on the PEX-A pipe ends to the fittings according to PEX-A system manufacturer instructions.
  4. ຕິດຕັ້ງເຄື່ອງວັດຄວາມດັນ: The pressure gauge is typically pre-installed. Ensure it is securely threaded into the designated port on the regulator body.
  5. Restore Water Supply and Check for Leaks: Slowly turn on the main water supply. Carefully inspect all connections for any signs of leaks. Tighten connections as necessary.
Apollo Water Pressure Regulator with PEX-A connections

ຮູບ 2: ຂ້າງ view of the Apollo Water Pressure Regulator, showing the double union PEX-A connections and the flow direction arrow. Note the "MAX INLET 400 PSI" marking.

5. ຄໍາແນະນໍາການດໍາເນີນງານ

The regulator is factory-set at 50 psi and is adjustable from 15 psi to 75 psi. No special tools are required for adjustment.

  1. ກວດ​ສອບ​ຄວາມ​ກົດ​ດັນ​ໃນ​ປັດ​ຈຸ​ບັນ​: Observe the reading on the integrated pressure gauge. The gauge is color-coded to indicate pressure ranges (e.g., Low, Optimal, Excessive).
  2. ການ​ປັບ​ຄວາມ​ກົດ​ດັນ​:
    • ເຖິງ ເພີ່ມຂຶ້ນ pressure: Turn the yellow adjustment handle ຕາມເຂັມໂມງ.
    • ເຖິງ ຫຼຸດລົງ pressure: Turn the yellow adjustment handle ກົງກັນຂ້າມກັບເຂັມໂມງ.
    • Make small adjustments and allow the system pressure to stabilize before re-checking the gauge.
  3. ຢືນຢັນການຕັ້ງຄ່າ: Once the desired pressure is achieved (typically between 50-60 psi for most residential applications), confirm the reading on the gauge.
Apollo Water Pressure Regulator with gauge showing optimal pressure range

ຮູບທີ 3: ໄລຍະໃກ້ view of the Apollo Water Pressure Regulator, highlighting the pressure gauge with its color-coded optimal range and the yellow adjustment handle.

6. ບໍາລຸງຮັກສາ

The Apollo Water Pressure Regulator is designed for minimal maintenance. Regular checks can help ensure optimal performance.

7. ການແກ້ໄຂບັນຫາ

ບັນຫາສາເຫດທີ່ເປັນໄປໄດ້ການແກ້ໄຂ
No water flow or very low pressure downstreamRegulator set too low; Main water supply off; Regulator clogged.Increase pressure setting; Check main water valve; Inspect for debris (consult a plumber if necessary).
Pressure too high downstreamRegulator set too high; Regulator malfunction.Decrease pressure setting; If problem persists, regulator may need replacement.
Water hammer or fluctuating pressureRapid changes in water demand; Regulator bypass mechanism issue.Ensure proper air chambers are installed in the plumbing system; Consult a plumber for regulator inspection.
ຮົ່ວໃນການເຊື່ອມຕໍ່Improperly tightened connections; Insufficient thread sealant.Tighten connections; Reapply thread sealant if necessary (ensure water supply is off first).

8. ຂໍ້ມູນຈໍາເພາະ

9. ການຮັບປະກັນແລະການສະຫນັບສະຫນູນ

This Apollo Water Pressure Regulator comes with a manufacturer's warranty. For specific warranty details, please refer to the documentation included with your purchase or contact Apollo customer support.

For technical support or inquiries, please visit the official Apollo webເວັບໄຊ ຫຼືຕິດຕໍ່ພະແນກບໍລິການລູກຄ້າຂອງເຂົາເຈົ້າ.

ເອກະສານທີ່ກ່ຽວຂ້ອງ - 69ELF114TWG

ກ່ອນview ຄູ່ມືຜູ້ໃຊ້ Apollo Air Electric Scooter - ການຕິດຕັ້ງ, ການດໍາເນີນງານ, ແລະຄວາມປອດໄພ
ຄູ່​ມື​ການ​ນໍາ​ໃຊ້​ທີ່​ສົມ​ບູນ​ແບບ​ສໍາ​ລັບ​ສະ​ກູດ​ເຕີ​ໄຟ​ຟ້າ Apollo Air​, ກວມ​ເອົາ​ການ​ຕິດ​ຕັ້ງ​, ການ​ດໍາ​ເນີນ​ງານ​, ຂໍ້​ແນະ​ນໍາ​ຄວາມ​ປອດ​ໄພ​, ການ​ບໍາ​ລຸງ​ຮັກ​ສາ​, ແລະ​ຂໍ້​ມູນ​ການ​ຮັບ​ປະ​ກັນ​. ຮຽນຮູ້ວິທີເພີດເພີນກັບ Apollo Air ຂອງທ່ານຢ່າງປອດໄພ.
ກ່ອນview ຄູ່ມືຜູ້ໃຊ້ Apollo Go Electric Scooter
ຄູ່​ມື​ການ​ນໍາ​ໃຊ້​ທີ່​ສົມ​ບູນ​ແບບ​ສໍາ​ລັບ​ສະ​ກູດ​ເຕີ​ໄຟ​ຟ້າ Apollo Go​, ກວມ​ເອົາ​ການ​ຕິດ​ຕັ້ງ​, ການ​ດໍາ​ເນີນ​ງານ​, ການ​ບໍາ​ລຸງ​ຮັກ​ສາ​, ການ​ແກ້​ໄຂ​ບັນ​ຫາ​, ແລະ​ຂໍ້​ແນະ​ນໍາ​ຄວາມ​ປອດ​ໄພ​.
ກ່ອນview Apollo POWER VS Series Turbine Instruction Manual - HVLP Spraying Guide
Comprehensive instruction manual for the Apollo POWER VS Series HVLP Turbine Spray Systems. Learn about setup, operation, maintenance, and best practices for achieving professional spray finishing results.
ກ່ອນview ຄູ່ມືຜູ້ໃຊ້ Apollo Go Electric Scooter
ຄູ່​ມື​ການ​ໃຊ້​ນີ້​ໃຫ້​ຄໍາ​ແນະ​ນໍາ​ທີ່​ສົມ​ບູນ​ແບບ​ສໍາ​ລັບ​ການ scooter Apollo Go ໄຟ​ຟ້າ​, ກວມ​ເອົາ​ການ unboxing​, ການ​ປະ​ກອບ​, ການ​ດໍາ​ເນີນ​ງານ​, ການ​ສາກ​ໄຟ​, ການ​ບໍາ​ລຸງ​ຮັກ​ສາ​, ຂໍ້​ແນະ​ນໍາ​ຄວາມ​ປອດ​ໄພ​, ການ​ແກ້​ໄຂ​ບັນ​ຫາ​, ແລະ​ຂໍ້​ມູນ​ການ​ຮັບ​ປະ​ກັນ​. ຮຽນ​ຮູ້​ວິ​ທີ​ການ​ຕັ້ງ​ຄ່າ​, ຂັບ​ເຄື່ອນ​, ແລະ​ການ​ດູ​ແລ​ສະ​ກູດ​ເຕີ​ໄຟ​ຟ້າ Apollo Go ຂອງ​ທ່ານ​.
ກ່ອນview Apollo 23G Electric Fireplace Insert Assembly and User Manual
Comprehensive guide for assembling and operating the Apollo 23G electric fireplace insert, including safety instructions, parts identification, and troubleshooting tips for model HF190108/OLLIEFIR.
ກ່ອນview Apollo SL15 Audio Selector Panel Installation Manual
This manual provides detailed installation and operation instructions for the Apollo SL15-series of Audio Selector Panel/Intercom Systems, including the SL15M with internal Marker Beacon. It covers general information, installation procedures, operation, and warranty.