1. ບົດແນະນຳ
This manual provides essential information for the proper installation, operation, and maintenance of your Zurn Wilkins 34-NR3XLDU 3/4 inch NR3XL Pressure Reducing Valve. Please read these instructions thoroughly before installation and retain them for future reference. Adherence to these guidelines will ensure optimal performance and longevity of the valve.
2. ຜະລິດຕະພັນເກີນview ແລະຄຸນສົມບັດ
The Zurn Wilkins 34-NR3XLDU Pressure Reducing Valve is designed for residential applications, effectively reducing high inlet pressure to a lower, more manageable outlet pressure. This helps protect plumbing systems and appliances from excessive pressure, while also contributing to water conservation.
- ການອອກແບບກະທັດຮັດ: Features a short lay length and compact design for installation in tight spaces.
- ການບໍາລຸງຮັກສາງ່າຍດາຍ: Cartridge-loaded design simplifies repairs and internal access.
- ການເຊື່ອມຕໍ່ອະເນກປະສົງ: Offers time- and labor-saving tailpiece options including threaded, PEX, copper sweat, and CPVC.
- ການປົກປ້ອງສິ່ງເສດເຫຼືອ: Includes a quality integral stainless steel strainer screen to prevent debris buildup.
- ການກໍ່ສ້າງທົນທານ: Highly durable, threaded bell resists corrosion and provides easy access to cartridge internals.
- ການຢັ້ງຢືນ: ASSE Listed 1003; IAPMO Listed; CSA Certified; Meets the requirements of NSF/ANSI 61.

ຮູບ 2.1: ດ້ານຫນ້າ view of the Zurn Wilkins 34-NR3XLDU Pressure Reducing Valve.

Figure 2.2: Key features of the NR3XL Pressure Reducing Valve.
3. ຂໍ້ມູນຄວາມປອດໄພ
- ແນະນຳການຕິດຕັ້ງແບບມືອາຊີບ: This valve should be installed by a qualified licensed plumber to ensure proper function and compliance with local codes.
- Water Supply Shut-off: ປິດແຫຼ່ງນ້ຳຫຼັກສະເໝີກ່ອນທີ່ຈະພະຍາຍາມຕິດຕັ້ງ ຫຼື ບຳລຸງຮັກສາໃດໆ.
- ການບັນເທົາຄວາມກົດດັນ: Open a downstream faucet to relieve pressure in the system before disassembling the valve.
- Hot Water Warning: Be aware that hot water can cause burns. Exercise caution when working with hot water lines.
- ຢ່າເຄັ່ງຄັດເກີນໄປ: Over-tightening connections can damage the valve and seals, leading to leaks.
4. ການຕິດຕັ້ງ
Follow these steps for proper installation of the Zurn Wilkins 34-NR3XLDU Pressure Reducing Valve. Refer to local plumbing codes for specific requirements.
- ກະກຽມພື້ນທີ່ການຕິດຕັ້ງ:
- Turn off the main water supply to the building.
- Open a downstream faucet to relieve pressure and drain water from the lines.
- Identify the location for the new pressure reducing valve. Ensure there is sufficient space for installation and future maintenance.
- Flush Supply Line:
- Before installing the valve, flush the supply line to remove any loose dirt, scale, or debris that could damage the valve's internal components.
- Install Valve In-Line:
- The valve body has an arrow indicating the direction of water flow. Install the valve so the arrow points in the direction of water flow towards the building.
- The valve can be installed in any orientation (horizontal, vertical, or diagonal).
- Use appropriate tools to connect the valve to your plumbing system. Ensure all connections are secure but do not over-tighten. The double union FNPT connections facilitate easy installation and removal.
- ຟື້ນຟູການສະຫນອງນ້ໍາ:
- Slowly turn on the main water supply, checking for any leaks at the connections.
- Open downstream faucets to purge air from the system.

Figure 4.1: Ensure the valve is installed with the flow arrow pointing correctly.

Figure 4.2: The threaded bell and fiber union gasket simplify installation.
ການຕິດຕັ້ງຫຼາຍກວ່າview ວິດີໂອ
ວິດີໂອທີ 4.1: ຈົບແລ້ວview of the Zurn Model NR3XL Pressure Reducing Valve, demonstrating its features and general installation considerations.
5. Setup: Adjusting Pressure
The Zurn Wilkins 34-NR3XLDU valve is factory set to approximately 50 PSI. You can adjust the outlet pressure within a range of 15-75 PSI.
- Attach Pressure Gauge: Connect a reliable pressure gauge to a downstream hose bib or test port to monitor the outlet pressure.
- Loosen Locknut: Locate the adjustment screw on top of the valve. Loosen the locknut securing the adjustment screw.
- ປັບຄວາມກົດດັນ:
- ເຖິງ ເພີ່ມຂຶ້ນ outlet pressure, turn the adjustment screw clockwise (into the bell housing).
- ເຖິງ ຫຼຸດລົງ outlet pressure, turn the adjustment screw counter-clockwise (out of the bell housing).
- ຢືນຢັນຄວາມກົດດັນ: After each adjustment, open a downstream faucet briefly to verify the correct pressure setting on your gauge.
- Tighten Locknut: Once the desired pressure is achieved, tighten the locknut to secure the adjustment screw.

Figure 5.1: The valve is designed for residential settings, including single-family and multi-family homes.
6. ຄໍາແນະນໍາການດໍາເນີນງານ
Once installed and adjusted, the Zurn Wilkins 34-NR3XLDU valve operates automatically to maintain a consistent downstream pressure, protecting your plumbing system. No further user interaction is typically required during normal operation.
- The valve continuously monitors and adjusts the water pressure entering your home.
- It is designed to reduce water usage and extend the life of pipes, faucets, and appliances by preventing high-pressure damage.
7. ບໍາລຸງຮັກສາ
ການບຳລຸງຮັກສາເປັນປະຈຳຮັບປະກັນປະສິດທິພາບ ແລະ ຄວາມໜ້າເຊື່ອຖືຢ່າງຕໍ່ເນື່ອງຂອງວາວຫຼຸດຄວາມດັນຂອງທ່ານ.
- ການກວດກາປະຈຳປີ: It is recommended that the valve be inspected annually by a qualified licensed plumber to verify correct pressure setting and overall condition.
- Strainer Screen Cleaning: The integral stainless steel strainer screen may require periodic cleaning, especially in areas with high sediment in the water supply. To clean:
- ປິດການສະຫນອງນ້ໍາຕົ້ນຕໍ.
- Relieve downstream pressure.
- Carefully disassemble the threaded bell to access the strainer screen.
- Clean the screen of any accumulated debris.
- Reassemble, ensuring all seals are properly seated and connections are secure.
- ການທົດແທນ Cartridge: The cartridge-loaded design allows for easy replacement of internal components if wear or damage occurs. Consult a qualified plumber for cartridge replacement.

Figure 7.1: The threaded bell allows for easy access to internal components for maintenance.
8. ການແກ້ໄຂບັນຫາ
If you experience issues with your pressure reducing valve, consider the following common problems and solutions:
- High Downstream Pressure:
- ການຂະຫຍາຍຄວາມຮ້ອນ: If pressure rises overnight or when hot water is used, it may be due to thermal expansion in the hot water heater. This is a normal phenomenon and typically requires an expansion tank. The pressure reducing valve is not designed to prevent thermal expansion.
- Improper Adjustment: Re-check the pressure adjustment screw setting using a pressure gauge (refer to Section 5).
- Debris in Valve: The valve may be fouled by debris, preventing it from closing completely. Clean the strainer screen and inspect the cartridge (refer to Section 7).
- ອົງປະກອບທີ່ເສຍຫາຍ: Internal components may be worn. A repair kit or replacement cartridge may be needed.
- Low Downstream Pressure/Flow:
- Improper Adjustment: The valve may be set too low. Adjust the pressure setting (refer to Section 5).
- Clogged Strainer: The integral strainer screen may be clogged with debris, restricting water flow. Clean the strainer screen (refer to Section 7).
- Inlet Pressure Too Low: Ensure the incoming main water supply pressure is adequate.
- ຮົ່ວ:
- ການເຊື່ອມຕໍ່ວ່າງ: Check all connections for tightness. Do not over-tighten.
- ປະທັບຕາທີ່ເສຍຫາຍ: Gaskets or O-rings may be damaged or improperly seated. Inspect and replace if necessary.
If troubleshooting steps do not resolve the issue, contact a qualified licensed plumber or Zurn customer support.
9. ຂໍ້ມູນຈໍາເພາະ
| ຄຸນລັກສະນະ | ລາຍລະອຽດ |
|---|---|
| ໝາຍເລກຕົວແບບ | 34-NR3XLDU |
| ຂະໜາດ | 3/4 ນິ້ວ |
| ວັດສະດຸ | ທອງເຫຼືອງ |
| ຂະໜາດສິນຄ້າ (L x W x H) | 5.5 x 2.8 x 5.5 ນິ້ວ |
| ນ້ໍາຫນັກລາຍການ | 2.15 ປອນ |
| ຂະໜາດການເຊື່ອມຕໍ່ຂາເຂົ້າ | 0.75 ນິ້ວ |
| ປະເພດການເຊື່ອມຕໍ່ຂາເຂົ້າ | ກະທູ້ |
| ຂະໜາດການເຊື່ອມຕໍ່ຂາອອກ | 0.75 ນິ້ວ |
| ປະເພດການເຊື່ອມຕໍ່ຂາອອກ | FNPT (Female National Pipe Taper) |
| ຊ່ວງຄວາມດັນທີ່ສາມາດປັບໄດ້ | 15 - 75 PSI |
| ຄວາມກົດດັນທາງເຂົ້າສູງສຸດ | 400 PSI |
| ອຸນຫະພູມສູງສຸດ | 140°F |
| ການຢັ້ງຢືນ | ASSE Listed 1003, IAPMO Listed, CSA Certified, Meets NSF/ANSI 61 |

Figure 9.1: Dimensions of the NR3XL Pressure Reducing Valve.

Figure 9.2: Certifications for the NR3XL Pressure Reducing Valve.
10. ການຮັບປະກັນແລະການສະຫນັບສະຫນູນ
For warranty information or technical support, please contact Zurn Industries, LLC directly. Keep your purchase receipt and model number handy when contacting support.
Zurn ອຸດສາຫະກໍາ, LLC
Webເວັບໄຊ: www.zurn.com