ແນະນຳ
This manual provides essential information for the safe installation, operation, and maintenance of your Akicon BPT16-14EL-L12 Bathroom Exhaust Fan with LED Light. Please read these instructions thoroughly before installation and use, and retain them for future reference.
The Akicon BPT16-14EL-L12 exhaust fan is designed to effectively remove moisture and odors from bathrooms and similar indoor spaces up to 85 square feet. It features a quiet operation at 1.5 sones and an integrated 12W LED light for illumination.

ລາຍລະອຽດຮູບພາບ: ດ້ານໜ້າ view of the Akicon BPT16-14EL-L12 bathroom exhaust fan, showcasing its white grille cover with integrated LED light and the metal housing with a black duct connector.
ຂໍ້ມູນຄວາມປອດໄພ
ຄໍາເຕືອນ: ເພື່ອຫຼຸດຜ່ອນຄວາມສ່ຽງທີ່ຈະເກີດໄຟໄຫມ້, ໄຟຟ້າ, ຫຼືບາດເຈັບຂອງຄົນ, ໃຫ້ສັງເກດດັ່ງຕໍ່ໄປນີ້:
- ວຽກງານຕິດຕັ້ງ ແລະ ສາຍໄຟຟ້າ ຕ້ອງເຮັດໂດຍຜູ້ມີຄຸນວຸດທິຕາມລະຫັດ ແລະ ມາດຕະຖານທັງໝົດ, ລວມທັງລະຫັດ ແລະ ມາດຕະຖານການກໍ່ສ້າງໄຟ.
- ໃຫ້ຖອດສາຍໄຟຢູ່ທີ່ແຜງບໍລິການສະເໝີກ່ອນເຊື່ອມຕໍ່ສາຍໄຟ ຫຼື ບໍລິການເຄື່ອງ.
- This unit is HVI-certified and cUL listed for use over bathtubs and showers when connected to a GFCI (Ground Fault Circuit Interrupter) protected branch circuit.
- ຫ້າມໃຊ້ພັດລົມນີ້ກັບອຸປະກອນຄວບຄຸມຄວາມໄວທີ່ແຂງແກ່ນ.
- Never place any object into the fan blades.
- ໃຫ້ແນ່ໃຈວ່າພັດລົມໄດ້ຕໍ່ສາຍດິນຢ່າງຖືກຕ້ອງ.
- Duct work must be installed with a minimum number of turns and runs to ensure optimal airflow.
ເນື້ອໃນຊຸດ
ກວດສອບວ່າອົງປະກອບທັງຫມົດແມ່ນມີຢູ່ກ່ອນທີ່ຈະເລີ່ມຕົ້ນການຕິດຕັ້ງ:
- Exhaust Fan Housing Assembly
- Grille Cover with Integrated LED Light
- 12W E26 Base LED Bulb (pre-installed or separate)
- Installation Hardware (screws, wire connectors)
- ຄູ່ມືຜູ້ໃຊ້ (ເອກະສານນີ້)
ຂໍ້ມູນຈໍາເພາະ
| ຄຸນສົມບັດ | ຂໍ້ມູນຈໍາເພາະ |
|---|---|
| ຍີ່ຫໍ້ | Akicon |
| ໝາຍເລກຕົວແບບ | BPT16-14EL-L12 |
| ຄວາມອາດສາມາດການໄຫຼວຽນຂອງອາກາດ | 90 ລູກບາດຟຸດຕໍ່ນາທີ (CFM) |
| ລະດັບສຽງ | 1.5 ຊິມ |
| ແຫຼ່ງພະລັງງານ | AC |
| ສະບັບtage | 120 ໂວນ |
| ໄຟ LED ວັດtage | 12 ວັດ |
| ອຸນຫະພູມແສງໄຟ LED | 5000K (ສີຂາວເຢັນ) |
| Housing Dimensions (L x W x H) | 9-3/8" x 9-3/8" x 7-5/16" |
| Grille Cover Size | 11" x 11" |
| ຂະ ໜາດ ທໍ່ | ຮອບ 4 ນິ້ວ |
| ຂະໜາດຫ້ອງທີ່ແນະນຳ | ເຖິງ 85 ຕາແມັດ. |
| ການຢັ້ງຢືນ | HVI, cUL Listed |
| ນ້ໍາຫນັກລາຍການ | 8.83 ປອນ |
ການຕິດຕັ້ງແລະການຕິດຕັ້ງ
This section outlines the general steps for installing the Akicon BPT16-14EL-L12 exhaust fan. For detailed diagrams and specific instructions, refer to the included installation guide or consult a qualified electrician.
1. ການພິຈາລະນາກ່ອນການຕິດຕັ້ງ
- Measure Room Size: Ensure the fan's 90 CFM capacity is suitable for your room (up to 85 sq. ft.).
- ການເປີດເພດານ: The recommended ceiling opening size is approximately 9-7/8" x 9-7/8". If replacing an existing fan, measure the current opening. If the existing opening is smaller, it will need to be enlarged to accommodate the new housing.
- ສາຍທໍ່: Plan for a 4-inch round duct connection. Use rigid metal ducting for best performance.
- ສາຍໄຟຟ້າ: Ensure a 120V AC power supply is available. The fan and light can be wired to operate jointly or separately via wall switches.

ລາຍລະອຽດຮູບພາບ: This image displays the critical dimensions for installation. It shows the fan housing size as 9-3/8" x 9-3/8" x 7-5/16", the grille cover size as 11" x 11", and the recommended ceiling opening size as 9-7/8" x 9-7/8". This helps ensure proper fit during installation.

ລາຍລະອຽດຮູບພາບ: An installation notice highlighting the housing dimensions (9.4" x 9.4" x 7.7") and emphasizing that the opening hole size should be based on the housing size. It advises checking existing opening sizes for replacements and cutting the hole to match the new housing if necessary.
2. Mounting the Fan Housing
- ປິດໄຟຢູ່ທີ່ຕົວຕັດວົງຈອນ.
- Cut the ceiling opening to the specified dimensions (approx. 9-7/8" x 9-7/8").
- Secure the fan housing to ceiling joists using appropriate fasteners. The housing is designed for screw-in installation. Ensure it is firmly attached to prevent vibration and noise.

ລາຍລະອຽດຮູບພາບ: This diagram shows two common installation scenarios: attic and soffit. It illustrates how the fan can be ducted to exhaust air outside, emphasizing the importance of proper ducting for effective ventilation.
3. Duct Connection
- Connect a 4-inch round duct to the fan's exhaust collar. Secure with duct tape or clamps.
- Route the duct to an exterior vent cap, ensuring minimal bends and a slight downward slope away from the fan to prevent condensation buildup.

ລາຍລະອຽດຮູບພາບ: A comprehensive installation diagram showing the fan housing, duct connection, and electrical wiring points. It provides a visual guide for the step-by-step installation process within a ceiling.
4. ສາຍໄຟຟ້າ
- Open the wiring compartment on the fan housing.
- Connect the household wiring to the fan's wiring according to local electrical codes. The fan and light have separate wires, allowing for independent operation if desired (e.g., separate wall switches for fan and light).
- Ensure all connections are secure and properly insulated. Close the wiring compartment cover.
5. Install Grille Cover
- If the LED bulb is not pre-installed, screw the 12W E26 base LED bulb into the socket.
- Attach the grille cover to the fan housing. Typically, this involves inserting mounting springs into slots in the housing and pushing the grille firmly against the ceiling.
Once installation is complete, restore power at the circuit breaker and test the fan and light functions.
ຄໍາແນະນໍາການດໍາເນີນງານ
The Akicon BPT16-14EL-L12 exhaust fan and LED light are designed for simple operation via standard wall switches.
- ປະຕິບັດການພັດລົມ: Flip the designated wall switch to turn the exhaust fan ON or OFF.
- ການດໍາເນີນງານແສງສະຫວ່າງ: Flip the designated wall switch to turn the LED light ON or OFF.
- If wired separately, the fan and light can be controlled independently. If wired jointly, both will activate simultaneously.
For optimal moisture and odor removal, operate the fan during and after showering or bathing for at least 15-20 minutes.
ບໍາລຸງຮັກສາ
Regular maintenance ensures optimal performance and longevity of your exhaust fan. Always disconnect power at the circuit breaker before performing any maintenance.
1. Cleaning the Grille Cover
- ຄ່ອຍໆດຶງຝາປິດກະจังໜ້າລົງເພື່ອຖອດມັນອອກຈາກສະປິງເຮືອນ.
- Wash the grille cover with mild soap and water. Rinse thoroughly and dry completely before reattaching.

ລາຍລະອຽດຮູບພາບ: ລາຍລະອຽດ view of the fan's white grille cover, showing the ventilation slots and the central LED light panel. This component is easily removable for cleaning.
2. Cleaning the Fan Interior
- With the grille removed and power off, carefully wipe down the fan blades and interior of the housing with a damp ຜ້າ.
- Do not allow water to enter the motor or electrical components.
- ຮັບປະກັນວ່າທຸກຊິ້ນສ່ວນແຫ້ງກ່ອນທີ່ຈະຟື້ນຟູພະລັງງານ.
3. LED Bulb Replacement
- ກວດໃຫ້ແນ່ໃຈວ່າປິດຢູ່.
- Remove the grille cover.
- Unscrew the old E26 base LED bulb and replace it with a new 12W E26 base LED bulb.
- Reattach the grille cover and restore power.
ການແກ້ໄຂບັນຫາ
If you encounter issues with your Akicon exhaust fan, refer to the following common problems and solutions:
| ບັນຫາ | ສາເຫດທີ່ເປັນໄປໄດ້ | ການແກ້ໄຂ |
|---|---|---|
| ພັດລົມບໍ່ເຮັດວຽກ / ໄຟບໍ່ເປີດ | No power supply; Loose wiring; Faulty switch; Blown fuse/tripped breaker | Check power at the circuit breaker. Ensure all wiring connections are secure. Test the wall switch. Replace fuse or reset breaker. |
| ພັດລົມມີສຽງດັງເກີນໄປ | Loose mounting; Obstruction in fan blades; Dirty fan blades/motor; Improper ducting | Ensure fan housing is securely mounted. Disconnect power and check for obstructions. Clean fan blades and motor. Inspect ductwork for kinks or blockages. |
| Poor ventilation performance | Ducting issues (too long, too many bends, wrong size); Blocked exterior vent; Room size exceeds fan capacity | Inspect ductwork for proper installation and clear any blockages. Ensure exterior vent is clear. Verify fan CFM matches room size. |
| ໄຟ LED ກະພິບ ຫຼື ມືດລົງ | Loose bulb; Faulty bulb; Wiring issue | Ensure bulb is screwed in tightly. Replace the LED bulb. Check electrical connections to the light. |
If the problem persists after attempting these solutions, please contact Akicon customer support.
ຂໍ້ມູນການຮັບປະກັນ
The Akicon BPT16-14EL-L12 Bathroom Exhaust Fan with LED Light comes with a ຮັບປະກັນ 3 ປີຈໍາກັດ ຈາກວັນທີ່ຊື້. ການຮັບປະກັນນີ້ກວມເອົາຂໍ້ບົກພ່ອງຂອງວັດສະດຸແລະການເຮັດວຽກພາຍໃຕ້ການນໍາໃຊ້ປົກກະຕິ.
The warranty does not cover damage resulting from improper installation, misuse, abuse, accident, neglect, or unauthorized repair or modification. Proof of purchase is required for all warranty claims.
ການຊ່ວຍເຫຼືອລູກຄ້າ
For any questions, technical assistance, or warranty claims, please contact Akicon customer service. Have your model number (BPT16-14EL-L12) and proof of purchase ready when contacting support.
Contact information can typically be found on the Akicon official webເວັບໄຊທ໌ຫຼືຜ່ານເວທີການຊື້ຂອງທ່ານ.