Megger MIT525-US

Megger MIT525-US 5kV Insulation Resistance Tester User Manual

Model: MIT525-US

1. ບົດແນະນຳ

This manual provides essential instructions for the safe and effective operation, setup, and maintenance of the Megger MIT525-US 5kV Insulation Resistance Tester. Please read this manual thoroughly before using the instrument to ensure proper functionality and to prevent potential hazards.

Megger MIT525-US 5kV Insulation Resistance Tester front view

ຮູບທີ 1: ດ້ານໜ້າ view of the Megger MIT525-US 5kV Insulation Resistance Tester. The device features a digital/analog display, control knobs, and test terminals. Note: The device shown in the image is a Megger MIT515, which is representative of the MIT series design.

2. ຂໍ້ມູນຄວາມປອດໄພ

Always adhere to the following safety precautions to prevent injury and damage to the instrument:

3. ຕັ້ງຄ່າ

3.1 ການຫຸ້ມຫໍ່ແລະການກວດກາ

Upon receiving your Megger MIT525-US, carefully unpack all components and inspect for any signs of damage. The package should include the main unit, test leads, and power cable.

3.2 ການເປີດອຸປະກອນ

The MIT525-US operates from line power (85 to 265 V, 50/60 Hz) or its internal lithium-ion battery. The battery charges automatically when connected to line power, even during operation.

  1. Connect the power cable to the instrument's power input and a suitable AC outlet.
  2. Allow approximately 2.5 hours for a full battery charge. A 0.5-hour charge provides approximately 1 hour of testing.

3.3 ການເຊື່ອມຕໍ່ຜູ້ນໍາການທົດສອບ

Connect the provided test leads to the appropriate terminals on the instrument. The MIT525-US features dedicated terminals for positive (+), negative (-), and guard connections.

4. ຄໍາແນະນໍາການດໍາເນີນງານ

4.1 Basic Insulation Resistance (IR) Test

The MIT525-US offers resistance measurement up to 10 TΩ for 5 kV models.

  1. ເປີດ: ຫັນປ່ຽນ rotary ກັບການທົດສອບທີ່ຕ້ອງການ voltage (e.g., 500 V, 1 kV, 2.5 kV, 5 kV). The instrument will power on and display the selected voltage.
  2. Connect to DUT: Connect the test leads to the Device Under Test (DUT) according to safety guidelines.
  3. Select Test Voltage: ໃຊ້ voltage selection knob to fine-tune the test voltage in 10 V steps (50 V to 1 kV) or 25 V steps (1 kV to max test voltagແລະ).
  4. ເລີ່ມການທົດສອບ: ກົດ ທົດສອບ button. The instrument will apply the test voltage and display the insulation resistance.
  5. ອ່ານການວັດແທກ: The digital/analog display will show the resistance value.
  6. Terminate Test: ປ່ອຍຕົວ ທົດສອບ button. The instrument will automatically discharge the DUT.

4.2 Advanced Diagnostic Tests

The MIT525-US supports various diagnostic tests including Polarization Index (PI), Dielectric Absorption Ratio (DAR), Dielectric Discharge (DD), Step Voltage (SV), and Ramp tests. These tests are crucial for assessing insulation quality and trending.

Refer to the on-screen menu and detailed instructions within the instrument's internal software for specific parameter settings and interpretation of results for advanced tests.

4.3 Voltmeter Function

The instrument includes a dedicated voltmeter function (30 V to 660 V) with frequency measurement to check for induced voltages on the circuit before testing.

  1. ຫັນສະວິດaryຸນໄປທີ່ V (Voltmeter) position.
  2. ເຊື່ອມຕໍ່ການທົດສອບນໍາໄປສູ່ວົງຈອນ.
  3. The display will show the measured voltage ແລະຄວາມຖີ່.

5. ບໍາລຸງຮັກສາ

5.1 ການທໍາຄວາມສະອາດ

Clean the instrument's exterior with a soft, damp cloth. Do not use abrasive cleaners or solvents. Ensure no moisture enters the instrument.

5.2 ການດູແລຫມໍ້ໄຟ

The lithium-ion battery is designed for extended capacity and rapid charging. For optimal battery life, avoid prolonged storage in a fully discharged state. Recharge the battery regularly.

5.3 ການປັບທຽບ

Regular calibration by authorized service centers is recommended to maintain the instrument's accuracy and performance. Refer to Megger's official website or contact support for calibration services.

6. ການແກ້ໄຂບັນຫາ

ບັນຫາສາເຫດທີ່ເປັນໄປໄດ້ການແກ້ໄຂ
ເຄື່ອງມືບໍ່ເປີດ.Discharged battery or no AC power.Connect to AC power and allow battery to charge.
ການອ່ານບໍ່ຖືກຕ້ອງ.Poor lead connections, environmental factors, or instrument out of calibration.Check lead connections. Ensure proper environmental conditions. Consider professional calibration.
ຂໍ້​ຄວາມ​ຜິດ​ພາດ​ໃນ​ການ​ສະ​ແດງ​.Specific operational error or internal fault.Refer to the instrument's on-screen error codes or contact Megger support.

For issues not listed here, please contact Megger technical support.

7. ຂໍ້ມູນຈໍາເພາະ

ພາລາມິເຕີມູນຄ່າ
ຕົວແບບMIT525-US
ທົດສອບ Voltage5.0 kV, 2.5 kV, 1.0 kV, 500 V, 250 V (10 V steps 50 V to 1 kV, 25 V steps 1 kV to max. test voltage)
ໄລຍະການວັດແທກຄວາມຕ້ານທານUp to 10 TΩ (for 5 kV models)
ໄລຍະການວັດແທກປັດຈຸບັນ0.01 nA ຫາ 6 mA
ຄວາມຖືກຕ້ອງ±5% up to 1 TΩ at 5 kV
Voltmeter Function30 V to 660 V with frequency measurement
ຈໍສະແດງຜົນDigital / Analog
ການສະຫນອງພະລັງງານLine power (85 to 265 V, 50/60 Hz, 60 VA) and rechargeable Lithium-ion battery
ເວລາສາກແບັດເຕີຣີ2.5 hours for full charge (0.5 hour charge for 1 hour testing)
ການຈັດອັນດັບຄວາມປອດໄພCAT IV 600 V on all terminals
ອຸນຫະພູມປະຕິບັດການ-4°F ຫາ +122°F (-20°C ຫາ +50°C)
ຂະໜາດ (ຊຸດ)17.4 x 14 x 12.6 ນິ້ວ
ນ້ຳໜັກ (ລາຍການ)16.9 ປອນ (7.67 ກິ​ໂລ​)

8. ການຮັບປະກັນແລະການສະຫນັບສະຫນູນ

For warranty information, technical support, or service inquiries, please contact Megger directly. Details can typically be found on the official Megger webສະຖານທີ່ ຫຼື ຜ່ານຜູ້ຈຳໜ່າຍທີ່ໄດ້ຮັບອະນຸຍາດຂອງທ່ານ.

ເອກະສານທີ່ກ່ຽວຂ້ອງ - MIT525-US

ກ່ອນview ເຄື່ອງທົດສອບຄວາມຕ້ານທານຂອງฉนวน Megger ADVANCED ລະດັບ 5 kV, 10 kV, 15 kV
ສຳຫຼວດເຄື່ອງທົດສອບຄວາມຕ້ານທານການສນວນ Megger ADVANCED ທີ່ແຂງແຮງ ແລະ ໜ້າເຊື່ອຖືໄດ້ໃນຊຸດ 5 kV, 10 kV, ແລະ 15 kV. ຄົ້ນພົບຄຸນສົມບັດຂັ້ນສູງເຊັ່ນ: ໂໝດ RE>Act ເພື່ອຄວາມແມ່ນຍຳທີ່ເພີ່ມຂຶ້ນ, ຕົວຄາດເດົາ PI ສຳລັບການທົດສອບທີ່ໄວຂຶ້ນ, ແລະ ລະດັບສຽງສູງ.tagຄວາມສາມາດຂອງ e ສູງເຖິງ 30 TΩ. ຖືກອອກແບບມາສຳລັບການນຳໃຊ້ໃນອຸດສາຫະກຳ, ເຄື່ອງທົດສອບເຫຼົ່ານີ້ສະເໜີຄວາມປອດໄພທີ່ດີກວ່າ (ຈັດອັນດັບ CAT IV) ແລະ ການເຮັດວຽກທີ່ງ່າຍດາຍ ເພື່ອການບຳລຸງຮັກສາ ແລະ ການທົດສອບໄຟຟ້າທີ່ມີປະສິດທິພາບ.
ກ່ອນview Megger MIT515 / MIT525 / MIT1025 / MIT1525 Insulation Resistance Testers User Guide
Comprehensive user guide for Megger MIT515, MIT525, MIT1025, and MIT1525 series 5 kV, 10 kV, and 15 kV Insulation Resistance Testers, covering operation, safety, specifications, and maintenance.
ກ່ອນview Megger ADVANCED Range: 5 kV, 10 kV, 15 kV Insulation Resistance Testers
Explore the robust and reliable Megger ADVANCED range of 5 kV, 10 kV, and 15 kV insulation resistance testers. Discover advanced features, safety ratings, and specifications for demanding electrical testing applications.
ກ່ອນview Megger Essential Range 5 kV ແລະ 10 kV Insulation Resistance Testers | ເອກະສານຂໍ້ມູນຜະລິດຕະພັນ
ສຳຫຼວດລະດັບ Megger Essential ຂອງ 5 kV ແລະ 10 kV Insulation Resistance Testers. ຄົ້ນພົບຄຸນສົມບັດເຊັ່ນ: RE>Act mode, PI predictor, ແລະລາຍລະອຽດສະເພາະສໍາລັບການທົດສອບໄຟຟ້າທີ່ເຊື່ອຖືໄດ້.
ກ່ອນview Megger MFT1741 Multifunction Tester: Features, Specifications, and Applications
ຮອບດ້ານview of the Megger MFT1741 Multifunction Tester, detailing its advanced features like non-trip loop impedance testing, 'Confidence Meter' analysis, and extensive RCD testing capabilities for industrial, commercial, and domestic electrical installations. Includes full specifications and ordering information.
ກ່ອນview ເຄື່ອງທົດສອບຄວາມສນວນ Megger MIT400/2 CAT IV: ຄຸນສົມບັດ, ສະເປັກ ແລະ ການນຳໃຊ້
ເອກະສານຂໍ້ມູນທີ່ສົມບູນແບບສຳລັບເຄື່ອງທົດສອບການສນວນ ແລະ ຄວາມຕໍ່ເນື່ອງ CAT IV ຂອງ Megger MIT400/2. ລາຍລະອຽດຄຸນສົມບັດ, ສະເປັກ, ການນຳໃຊ້, ຄວາມປອດໄພ ແລະ ການປຽບທຽບຮູບແບບສຳລັບການທົດສອບທາງໄຟຟ້າ ແລະ ອຸດສາຫະກຳ.