Hager ADC810H

Hager ADC810H Residual Current Circuit Breaker with Overcurrent Protection (RCBO) User Manual

ຕົວແບບ: ADC810H | ຍີ່ຫໍ້: ແຮກເກີ

1. ບົດແນະນຳ

The Hager ADC810H is a compact and reliable Residual Current Circuit Breaker with Overcurrent Protection (RCBO), designed for the protection of electrical installations against both overcurrents (overload and short-circuit) and earth leakage currents. This device is a bipolar 1P+N unit, suitable for single-phase systems, ensuring enhanced safety and operational flexibility. Its design facilitates easy installation in industrial and domestic environments, providing precise monitoring of differential currents.

2. ຄໍາແນະນໍາຄວາມປອດໄພ

WARNING: Electrical work should only be performed by qualified and authorized personnel. Failure to follow these instructions can result in serious injury or death.

  • Always disconnect the main power supply before installing, maintaining, or troubleshooting the device.
  • Ensure proper grounding of the electrical system.
  • Verify that the device ratings (voltage, current, breaking capacity) match the requirements of your electrical installation.
  • ຢ່າໃຊ້ອຸປະກອນຖ້າມັນປະກົດວ່າເສຍຫາຍ.
  • Regularly test the residual current function using the test button.

3. ຜະລິດຕະພັນເກີນview

The Hager ADC810H RCBO integrates both overcurrent and residual current protection in a single compact unit. It features a robust housing and clear markings for easy identification and connection.

Hager ADC810H RCBO front view ກັບ terminals

ຮູບພາບນີ້ສະແດງໃຫ້ເຫັນທາງຫນ້າ view of the Hager ADC810H Residual Current Circuit Breaker with Overcurrent Protection (RCBO). Visible are the toggle switch for manual operation, the test button, and the connection terminals for phase and neutral conductors.

ອົງປະກອບຫຼັກປະກອບມີ:

  • ສະຫຼັບສັບ: For manual ON/OFF operation and indication of trip status.
  • ປຸ່ມທົດສອບ: Used to periodically test the residual current tripping mechanism.
  • ຈຸດເຊື່ອມຕໍ່: Clearly marked for phase (L) and neutral (N) input and output.
  • DIN Rail Mounting Clip: For secure installation on a DIN rail.

4. ການຕິດຕັ້ງ

The Hager ADC810H RCBO is designed for DIN rail mounting. Follow these steps for safe and correct installation:

  1. ການຕັດການເຊື່ອມຕໍ່ໄຟຟ້າ: Ensure the main power supply to the installation is completely disconnected and secured against accidental re-connection.
  2. ການຕິດຕັ້ງ: Clip the RCBO onto the DIN rail in the consumer unit or distribution board. Ensure it is securely seated.
  3. Wiring - Input: Connect the incoming phase (L) and neutral (N) conductors to the upper terminals of the RCBO. Ensure correct polarity and tight connections.
  4. Wiring - Output: Connect the outgoing phase (L) and neutral (N) conductors to the lower terminals of the RCBO, leading to the protected circuit. Ensure correct polarity and tight connections.
  5. ແຮງບິດ: Tighten all terminal screws to the manufacturer's specified torque to prevent loose connections and overheating.
  6. ການຢັ້ງຢືນ: ກວດສອບການເຊື່ອມຕໍ່ທັງໝົດຄືນໃໝ່ເພື່ອຄວາມຖືກຕ້ອງ ແລະ ຄວາມປອດໄພກ່ອນທີ່ຈະສົ່ງໄຟຟ້າຄືນໃໝ່.

5. ການດໍາເນີນງານ

The RCBO operates automatically to protect against electrical faults. Manual operation is also possible:

  • ກຳລັງເປີດ: Push the toggle switch upwards to the 'ON' position.
  • ກຳລັງປິດ: Push the toggle switch downwards to the 'OFF' position.
  • ການເດີນທາງອັດຕະໂນມັດ: In the event of an overcurrent (overload or short-circuit) or an earth leakage current exceeding 30mA, the RCBO will automatically trip, moving the toggle switch to the 'OFF' or intermediate position.
  • ຟັງຊັນການທົດສອບ: Press the 'T' (Test) button periodically (e.g., monthly) to verify the residual current tripping mechanism. The RCBO should trip immediately. If it does not trip, the device may be faulty and requires replacement.

6. ບໍາລຸງຮັກສາ

The Hager ADC810H RCBO requires minimal maintenance, but regular checks are essential for continued safety and performance:

  • ການກວດກາສາຍຕາ: ກວດ​ເບິ່ງ​ອຸ​ປະ​ກອນ​ເປັນ​ໄລ​ຍະ​ເວ​ລາ​ສໍາ​ລັບ​ອາ​ການ​ຂອງ​ຄວາມ​ເສຍ​ຫາຍ​ທາງ​ດ້ານ​ຮ່າງ​ກາຍ​, ການ​ປ່ຽນ​ສີ​, ຫຼື​ການ​ເຊື່ອມ​ຕໍ່​ຂາດ​.
  • Test Button Operation: Perform the test button operation monthly as described in the 'Operation' section.
  • ທໍາຄວາມສະອາດ: If necessary, clean the exterior of the device with a dry, soft cloth. Do not use abrasive cleaners or solvents.
  • ການກວດກາແບບມືອາຊີບ: It is recommended to have the entire electrical installation, including protective devices, inspected by a qualified electrician at regular intervals as per local regulations.

7. ການແກ້ໄຂບັນຫາ

If the RCBO trips unexpectedly or fails to operate correctly, consider the following:

  • RCBO Trips Immediately After Reset:
    • ສາເຫດທີ່ເປັນໄປໄດ້: Persistent earth fault or short-circuit in the protected circuit.
    • ການແກ້ໄຂ: Disconnect all loads from the circuit. If the RCBO still trips, there is a fault in the fixed wiring. If it holds, reconnect loads one by one to identify the faulty appliance. Consult a qualified electrician.
  • RCBO Trips Intermittently:
    • ສາເຫດທີ່ເປັນໄປໄດ້: Intermittent earth fault, overloaded circuit, or faulty appliance.
    • ການແກ້ໄຂ: Reduce the load on the circuit. Check appliances for intermittent faults.
  • RCBO ບໍ່ເຮັດວຽກເມື່ອກົດປຸ່ມທົດສອບ:
    • ສາເຫດທີ່ເປັນໄປໄດ້: Faulty RCBO.
    • ການແກ້ໄຂ: The device is not providing residual current protection and must be replaced immediately by a qualified electrician.
  • No Power to Circuit, RCBO is ON:
    • ສາເຫດທີ່ເປັນໄປໄດ້: Loose connection, fault upstream (e.g., main breaker tripped), or internal device failure.
    • ການແກ້ໄຂ: Check all connections. Verify power supply to the RCBO. If issues persist, consult a qualified electrician.

8. ຂໍ້ກໍານົດດ້ານວິຊາການ

ພາລາມິເຕີມູນຄ່າ
ຍີ່ຫໍ້ແຮກເກີ
ໝາຍເລກຕົວແບບADC810H
ປະເພດRCBO (Residual Current Circuit Breaker with Overcurrent Protection)
ເສົາ1P+N (Bipolar Phase Neutral)
ອັນດັບທີtage (Vac)230 ວ
ຄວາມຖີ່50/60 Hz
ອັນດັບປັດຈຸບັນ10 ກ
ປະເມີນຄ່າກະແສໄຟຟ້າທີ່ຕົກຄ້າງ (IΔn)30 mA (0.03A)
ຂີດຄວາມສາມາດ4.5 ກ
Overcurrent Trip CurveC
Magnetic Trip Range5 ຫາ 10 In
Type of Residual Current UnitAC (for alternating current only)
ລະດັບການປົກປ້ອງIP20
ປະເພດການຕິດຕັ້ງບໍລິສັດ DIN Rail
ຈຳ ນວນໂມດູນ2
ຂະໜາດ (ປະມານ)10 x 7 x 4 cm
ນ້ຳໜັກ (ປະມານ)500 g

9. ຂໍ້ມູນການຮັບປະກັນ

Hager products are manufactured to high-quality standards and are covered by a manufacturer's warranty against defects in materials and workmanship. The specific terms and duration of the warranty may vary by region and product. Please refer to the official Hager website or contact your local supplier for detailed warranty information applicable to your purchase. Keep your proof of purchase for warranty claims.

10. ສະຫນັບສະຫນູນແລະຕິດຕໍ່

For technical assistance, product inquiries, or support, please contact Hager customer service or your authorized Hager distributor. You can typically find contact information on the official Hager website or on the product packaging. When contacting support, please have your product model number (ADC810H) and any relevant purchase details ready.

Hager ຢ່າງເປັນທາງການ Webເວັບໄຊ: www.hager.com

ເອກະສານທີ່ກ່ຽວຂ້ອງ - ADC810H

ກ່ອນview Hager ADC932R RCBO: ຄູ່ມືການຕິດຕັ້ງແລະການນໍາໃຊ້
ຄູ່ມືນີ້ສະຫນອງຂໍ້ມູນທີ່ຈໍາເປັນສໍາລັບການຕິດຕັ້ງແລະນໍາໃຊ້ Hager ADC932R Residual Current Operated Circuit-Breaker (RCBO) ທີ່ມີການປ່ຽນເປັນກາງ. ມັນກວມເອົາການເຊື່ອມຕໍ່ໄຟຟ້າ, ການຕິດຕັ້ງ, ການທົດສອບ, ແລະຄໍາແນະນໍາຄໍາຮ້ອງສະຫມັກສະເພາະ, ລວມທັງການຕິດຕັ້ງ charger EV.
ກ່ອນview Hager RCBO Residual Current Circuit Breaker with Switched Neutral (6-32A) - ຄູ່ມືການຕິດຕັ້ງແລະການດໍາເນີນງານ
ເອກະສານນີ້ໃຫ້ຄໍາແນະນໍາການຕິດຕັ້ງ ແລະການປະຕິບັດສໍາລັບ Hager Residual Current Operated Circuit-Breaker (RCBO) ທີ່ມີການປ່ຽນເປັນກາງ, ກວມເອົາຕົວແບບຈາກ 6 ຫາ 32. Ampເອີ. ມັນລາຍລະອຽດກ່ຽວກັບການເຊື່ອມຕໍ່ໄຟຟ້າ, ການຕິດຕັ້ງ, ການທົດສອບ, ແລະບັນທຶກຄໍາຮ້ອງສະຫມັກສະເພາະສໍາລັບ EVCS.
ກ່ອນview Hager RCBO ຄູ່ມືການຕິດຕັ້ງແລະຄໍາແນະນໍາ
ຄູ່ມືທີ່ສົມບູນແບບສໍາລັບການຕິດຕັ້ງແລະການນໍາໃຊ້ Hager Residual Current Operated Circuit-Breakers (RCBOs), ລວມທັງການເຊື່ອມຕໍ່ໄຟຟ້າ, ການຕິດຕັ້ງ, ການທົດສອບ, ແລະຄໍາແນະນໍາສະເພາະສໍາລັບຄໍາຮ້ອງສະຫມັກ EVCS.
ກ່ອນview Hager RCBO ຄໍາແນະນໍາຄໍາຮ້ອງສະຫມັກ: ຮັບປະກັນການຕິດຕັ້ງທີ່ຖືກຕ້ອງ
ຄໍາແນະນໍາຈາກ Hager ກ່ຽວກັບຄໍາຮ້ອງສະຫມັກ RCBO, ກວມເອົາບັນຫາທີ່ມີການປ່ຽນເປັນກາງແລະ RCBOs unidirectional, ມີວິທີແກ້ໄຂສໍາລັບການຕິດຕັ້ງທີ່ຖືກຕ້ອງແລະການເລືອກຜະລິດຕະພັນ. ລວມມີລາຍລະອຽດດ້ານວິຊາການສໍາລັບແບບ ADC920R ແລະ ADA920U.
ກ່ອນview Hager Residual Breakers ປະຈຸບັນປະຕິບັດການຕິດຕັ້ງ RCBO 6-50A ແລະຄູ່ມືຄວາມປອດໄພ
ເອກະສານນີ້ໃຫ້ຄໍາແນະນໍາການຕິດຕັ້ງແລະຄໍາເຕືອນຄວາມປອດໄພສໍາລັບ Hager Residual Current Breakers Operated RCBO 6-50A. ມັນລາຍລະອຽດຂໍ້ມູນການຮັບປະກັນ, ແຜນວາດໄຟຟ້າ, ແລະຂັ້ນຕອນການດໍາເນີນງານສໍາລັບຜູ້ຮັບເຫມົາທີ່ມີຄຸນວຸດທິ.
ກ່ອນview Hager Consumer Unit AFDD Installation Guidance Notes for RCBO and MCB
Comprehensive installation guidance notes from Hager for Consumer Unit AFDD Single Mod, covering RCBO and MCB devices, switch disconnectors, and dual RCCB units. Includes retrofitting information and rating derating guidelines for electrical installations.