Field Controls UV 16

Field Controls UV-16/120 UV-Aire In Duct Air Purifier

ຄູ່ມືຜູ້ໃຊ້

1. ການແນະນໍາແລະຜະລິດຕະພັນຫຼາຍກວ່າview

The Field Controls UV-16/120 UV-Aire In Duct Air Purifier is designed to improve indoor air quality by utilizing ultraviolet (UV-C) light technology. This device is installed directly into your HVAC system's ductwork, where it neutralizes airborne contaminants such as bacteria, viruses, mold spores, and allergens as air passes through. This manual provides essential information for the safe and effective installation, operation, and maintenance of your UV-Aire system.

Field Controls UV-16/120 UV-Aire In Duct Air Purifier unit with a glowing UV lamp extending from the side.

This image displays the Field Controls UV-16/120 UV-Aire In Duct Air Purifier, a compact white unit designed for installation within HVAC ductwork. A blue glowing UV lamp is visible extending from the right side of the main housing, indicating its air purification function.

2. ຂໍ້ມູນຄວາມປອດໄພ

ກະລຸນາອ່ານຄໍາແນະນໍາດ້ານຄວາມປອດໄພທັງໝົດຢ່າງລະມັດລະວັງກ່ອນການຕິດຕັ້ງ ແລະການດໍາເນີນງານ. ການບໍ່ປະຕິບັດຕາມຄໍາແນະນໍາເຫຼົ່ານີ້ອາດຈະເຮັດໃຫ້ໄຟຟ້າຊ໊ອກ, ໄຟໄຫມ້, ຫຼືບາດເຈັບສາຫັດ.

3. ເນື້ອໃນຊຸດ

Verify that all components are present and undamaged before beginning installation. If any items are missing or damaged, contact your supplier immediately.

4. ການຕິດຕັ້ງແລະການຕິດຕັ້ງ

The UV-16/120 UV-Aire unit is designed for installation within the return or supply air duct of your HVAC system. Proper placement is crucial for effective air purification.

  1. ການຕັດການເຊື່ອມຕໍ່ໄຟຟ້າ: Turn off all power to the HVAC system at the main electrical panel or circuit breaker. Verify power is off using a voltage ເຄື່ອງທົດສອບ.
  2. ເລືອກສະຖານທີ່ຕິດຕັ້ງ: Choose a location in the ductwork that allows for sufficient airflow around the UV lamp and provides easy access for future maintenance (e.g., bulb replacement). Ensure there is at least 16 inches of clear space for the lamp.
  3. ຕັດ​ເປີດ​: Using the provided template (if applicable) or the unit's dimensions, carefully cut an opening in the ductwork for the main housing of the UV-Aire unit. Ensure the opening is clean and free of sharp edges.
  4. Mount the Unit: Insert the UV-Aire unit into the cut opening. Secure the unit to the ductwork using the provided mounting screws. Ensure a tight seal to prevent air leakage.
  5. ການເຊື່ອມຕໍ່ໄຟຟ້າ: Connect the unit's power cord to a dedicated 120 Volt power source, typically wired into the HVAC system's control circuit so it operates when the fan is running. Follow all local electrical codes. The unit features a safety disconnect for added protection.
  6. ຕິດຕັ້ງ UV Lamp: ຖ້າ lamp is not pre-installed, carefully insert the UV-C lamp into its receptacle on the unit. Ensure it is securely seated. Avoid touching the glass portion of the lamp ດ້ວຍມືເປົ່າ.
  7. ຟື້ນຟູພະລັງງານ: Once installation is complete and all connections are secure, restore power to the HVAC system.

5. ຄໍາແນະນໍາການດໍາເນີນງານ

The Field Controls UV-16/120 UV-Aire In Duct Air Purifier is designed for continuous operation when your HVAC system's fan is running. It does not require daily user interaction.

6. ບໍາລຸງຮັກສາ

Regular maintenance ensures the continued effectiveness and longevity of your UV-Aire system.

7. ການແກ້ໄຂບັນຫາ

If your UV-Aire system is not functioning as expected, refer to the following common issues and solutions:

ບັນຫາສາເຫດທີ່ເປັນໄປໄດ້ການແກ້ໄຂ
UV lamp ບໍ່ໄດ້ສະຫວ່າງບໍ່ມີພະລັງງານກັບຫນ່ວຍບໍລິການCheck circuit breaker. Ensure HVAC fan is running if wired to fan circuit.
UV lamp ບໍ່ໄດ້ສະຫວ່າງLamp has reached end of lifeທົດແທນ UV lamp (ເບິ່ງພາກການບໍາລຸງຮັກສາ).
UV lamp ບໍ່ໄດ້ສະຫວ່າງballast ຜິດ​ພາດ​Contact a qualified technician for inspection and replacement of the ballast. (Note: Some users have reported ballast failure after extended use.)
Reduced air purification effectivenessLamp is old or dirtyReplace or clean the UV lamp.
ຫນ່ວຍ​ງານ​ເຮັດ​ໃຫ້​ມີ​ສຽງ​ຜິດ​ປົກ​ກະ​ຕິ​Loose mounting or internal component issueEnsure unit is securely mounted. If noise persists, contact a qualified technician.

If the problem persists after attempting these solutions, contact Field Controls customer support or a qualified HVAC professional.

8. ຂໍ້ມູນຈໍາເພາະ

Key technical specifications for the Field Controls UV-16/120 UV-Aire In Duct Air Purifier:

9. ຂໍ້ມູນການຮັບປະກັນ

Specific warranty terms for the Field Controls UV-16/120 UV-Aire In Duct Air Purifier are typically provided at the time of purchase or can be obtained directly from Field Controls or your authorized dealer. It is recommended to retain your proof of purchase for warranty claims.

Extended protection plans may be available from third-party providers at the point of sale. These plans are separate from the manufacturer's warranty.

10. ສະຫນັບສະຫນູນ

For technical assistance, replacement parts, or further inquiries regarding your Field Controls UV-16/120 UV-Aire In Duct Air Purifier, please contact:

When contacting support, please have your product model number (UV 16) and date of purchase readily available.