ແນະນຳ
This manual provides essential information for the safe and effective installation, operation, and maintenance of the Idec RH2B-UL-AC110-120V Electromechanical Relay. Please read this manual thoroughly before using the product to ensure proper function and to prevent potential hazards.
ຂໍ້ມູນຄວາມປອດໄພ
WARNING: Electrical shock hazard. Installation and maintenance should only be performed by qualified personnel. Disconnect all power before working with the relay.
- Always ensure power is disconnected before installation, wiring, or maintenance.
- ຢືນຢັນ voltage and current ratings before connecting the relay to a circuit.
- Do not operate the relay in environments exceeding its specified temperature or humidity limits.
- ຮັບປະກັນການຖົມດິນຢ່າງຖືກຕ້ອງຕາມທີ່ເໝາະສົມ.
ສິນຄ້າເກີນview
The Idec RH2B-UL-AC110-120V is a general-purpose electromechanical relay designed for various industrial control applications. It features a compact design and is suitable for DIN rail mounting.

Figure 1: Idec RH2B-UL-AC110-120V Relays in their original packaging, showing a pack of four units.

Figure 2: A single Idec RH2B-UL-AC110-120V relay, providing an angled view of the transparent casing ແລະອົງປະກອບພາຍໃນ.
ການຕິດຕັ້ງແລະການຕິດຕັ້ງ
Follow these steps for proper installation of the Idec RH2B-UL-AC110-120V Relay:
- ການຕັດການເຊື່ອມຕໍ່ໄຟຟ້າ: Ensure all power to the circuit is completely disconnected before beginning installation.
- ການຕິດຕັ້ງ: The relay is designed for DIN Rail mounting. Securely attach the relay to a standard DIN rail in your control panel.
- ສາຍໄຟ: The relay utilizes through-hole connectors. Carefully connect the control circuit wiring to the coil terminals and the load circuit wiring to the contact terminals. Refer to the wiring diagram (if available in your system documentation) for specific terminal assignments.

ຮູບທີ 3: ດ້ານລຸ່ມ view of the relay, showing the through-hole connector pins for wiring connections.
- ສະບັບtage ການຢັ້ງຢືນ: ຢືນຢັນວ່າການສະຫນອງ voltage for the coil matches the relay's specified voltage ຂອງ 110-120V AC, 50/60Hz.

ຮູບທີ 4: ໄລຍະໃກ້ view of the relay's transparent casing, highlighting the model number and voltage specifications (AC110-120V, 50/60Hz).
- Load Verification: Ensure the connected load does not exceed the relay's contact ratings (e.g., 10A resistive at 240VAC).

ຮູບ 5: ຂ້າງ view of the relay, displaying detailed electrical ratings and certifications.
- ກວດສອບຄັ້ງສຸດທ້າຍ: Before restoring power, double-check all connections for security and correctness.
ຄໍາແນະນໍາການດໍາເນີນງານ
The Idec RH2B-UL-AC110-120V Relay operates automatically based on the control signal applied to its coil. When the specified AC voltage (110-120V) is applied to the coil, the relay contacts will switch, opening or closing the connected load circuit. When the voltage is removed, the contacts return to their original state.
- Ensure the control signal is within the specified voltage range for reliable operation.
- Observe any indicator lights on the relay (if present) to confirm coil energization.
ບໍາລຸງຮັກສາ
The Idec RH2B-UL-AC110-120V Relay is designed for long-term, reliable operation with minimal maintenance. However, periodic inspection is recommended:
- ການກວດກາສາຍຕາ: ກວດເບິ່ງການສົ່ງຕໍ່ເປັນໄລຍະສໍາລັບອາການໃດໆຂອງຄວາມເສຍຫາຍທາງດ້ານຮ່າງກາຍ, ການປ່ຽນສີ, ຫຼືການເຊື່ອມຕໍ່ວ່າງ.
- ທໍາຄວາມສະອາດ: If necessary, gently clean the exterior of the relay with a dry, soft cloth. Do not use solvents or abrasive cleaners.
- Contact Inspection: In critical applications, inspect contacts for pitting or wear. Replace the relay if significant wear is observed.
- ເງື່ອນໄຂສິ່ງແວດລ້ອມ: ຮັບປະກັນວ່າສະພາບແວດລ້ອມການດຳເນີນງານຍັງຄົງຢູ່ພາຍໃນຂອບເຂດອຸນຫະພູມ ແລະ ຄວາມຊຸ່ມຊື່ນທີ່ກຳນົດໄວ້ເພື່ອປ້ອງກັນການລົ້ມເຫຼວກ່ອນໄວອັນຄວນ.
ການແກ້ໄຂບັນຫາ
If the relay is not functioning as expected, consider the following common issues:
| ບັນຫາ | ສາເຫດທີ່ເປັນໄປໄດ້ | ການແກ້ໄຂ |
|---|---|---|
| Relay coil does not energize. | No power to coil, incorrect voltage, faulty wiring, or damaged coil. | Check power supply, verify voltage (110-120V AC), inspect wiring connections, test coil continuity. |
| Contacts do not switch. | Coil not energizing, contacts welded, or mechanical failure. | Refer to "Relay coil does not energize" solutions. If coil is good, replace relay. |
| Load not receiving power. | Relay contacts not closing, open circuit in load wiring, or faulty load. | Verify relay operation. Check load circuit wiring and the load itself. |
If troubleshooting steps do not resolve the issue, contact Idec technical support or a qualified electrician.
ຂໍ້ມູນຈໍາເພາະ
| ພາລາມິເຕີ | ມູນຄ່າ |
|---|---|
| ໝາຍເລກຕົວແບບ | RH2B-UL-AC110-120V |
| ຍີ່ຫໍ້ | ໄອເດກ |
| Coil Voltage | 110-120V AC |
| ຄວາມຖີ່ | 50/60 Hz |
| Current Rating (Resistive) | 10A @ 240VAC, 10A @ 30VDC |
| Current Rating (General Use) | 7.5A @ 120VAC, 7A @ 240VAC, 7.5A @ 30VDC |
| ຄະແນນແຮງມ້າ | 1/6 HP @ 120VAC, 1/3 HP @ 240VAC |
| ປະເພດການຕິດຕັ້ງ | DIN Rail Mount |
| ປະເພດຕົວເຊື່ອມຕໍ່ | ຜ່ານຂຸມ |
| ຮູບແບບການເຮັດວຽກ | ອັດຕະໂນມັດ |
| ນ້ໍາຫນັກລາຍການ | 0.01 ອອນ |
| ຜູ້ຜະລິດ | ໄອເດກ |
ການຮັບປະກັນແລະການສະຫນັບສະຫນູນ
For warranty information and technical support, please contact Idec directly through their official webເວັບໄຊທ໌ ຫຼື ຊ່ອງທາງການບໍລິການລູກຄ້າ. ເກັບຮັກສາໃບຮັບເງິນການຊື້ຂອງທ່ານໄວ້ສຳລັບການຮຽກຮ້ອງການຮັບປະກັນ.
Idec Official Webເວັບໄຊ: us.idec.com