Simplex 4098-9792

ຄູ່ມືຜູ້ໃຊ້

SIMPLEXGRINNELL 4098-9792 ADDRESSABLE, SSD Sensor Base

Model: 4098-9792 | Brand: Simplex

ສິນຄ້າເກີນview

The Simplex 4098-9792 is an addressable SSD (Smoke Sensor Detector) sensor base designed for use with Simplex Intelligent Control Panels. This flanged, 4.875-inch snap-in base provides the necessary electrical and mechanical interface for compatible smoke sensors, ensuring reliable communication within a fire alarm system. Its white finish and robust construction are suitable for various indoor installations.

Image of the Simplex 4098-9792 SSD Sensor Base, showing the internal wiring terminals and mounting points.

This image displays the Simplex 4098-9792 SSD Sensor Base, a white, circular unit designed for mounting addressable sensors. The internal view reveals the various wiring terminals, including a black DIP switch block for address configuration, and mounting screw holes. The flanged design is visible around the perimeter, facilitating secure installation.

ຄຸນ​ນະ​ສົມ​ບັດ​ທີ່​ສໍາ​ຄັນ​:

ຂໍ້ມູນຈໍາເພາະ

ຄຸນ​ລັກ​ສະ​ນະມູນຄ່າ
ຍີ່ຫໍ້ງ່າຍດາຍ
ຕົວແບບ4098-9792
ແບບແປນ
ສີສີຂາວ
ປະເພດປຸກFIRE (when connected to compatible sensor)
ເສັ້ນຜ່າສູນກາງ4.875 ນິ້ວ
ຄວາມເຂົ້າກັນໄດ້Simplex Intelligent Control Panel

ການຕິດຕັ້ງແລະການຕິດຕັ້ງ

1. ການກວດສອບການຕິດຕັ້ງກ່ອນ:

2. Mounting the Base:

  1. Secure the 4098-9792 sensor base to a standard electrical box or mounting bracket using appropriate screws. The flanged design allows for stable attachment.
  2. Ensure the base is firmly attached and level.

3. ສາຍໄຟ:

  1. Route the fire alarm circuit wiring through the opening in the base.
  2. Connect the circuit wires to the designated terminals on the sensor base as per the system wiring diagram provided by Simplex. Pay close attention to polarity.
  3. ໃຫ້ແນ່ໃຈວ່າການເຊື່ອມຕໍ່ທັງຫມົດແມ່ນປອດໄພແລະຖືກ insulated ຢ່າງຖືກຕ້ອງ.

4. Address Configuration:

  1. Set the unique address for the sensor base using the integrated DIP switches. Refer to the Simplex Intelligent Control Panel documentation for specific addressing procedures and available addresses.
  2. Each sensor base in the system must have a unique address.

5. ການຕິດຕັ້ງເຊັນເຊີ:

  1. Align the compatible Simplex SSD sensor with the snap-in mechanism of the base.
  2. Gently push and twist the sensor clockwise until it clicks securely into place.

ການດໍາເນີນງານ

Once installed and connected to a Simplex Intelligent Control Panel, the 4098-9792 sensor base facilitates communication between the attached sensor and the control panel. The base provides power to the sensor and transmits alarm, trouble, and supervisory signals back to the panel based on the sensor's readings. The addressable nature of the base allows the control panel to identify the exact location of any activated sensor.

ບໍາລຸງຮັກສາ

Regular maintenance is crucial for the reliable operation of your fire alarm system components, including the 4098-9792 sensor base and its attached sensor.

ຕາຕະລາງການບໍາລຸງຮັກສາທີ່ແນະນໍາ:

For detailed maintenance procedures for the attached sensor, refer to the specific sensor's user manual.

ການແກ້ໄຂບັນຫາ

This section provides guidance for common issues that may arise with the 4098-9792 sensor base. For complex issues, contact a qualified fire alarm technician.

ບັນຫາສາເຫດທີ່ເປັນໄປໄດ້ການແກ້ໄຂ
Sensor not communicating with panelIncorrect wiring; Incorrect address setting; Faulty sensor; Loose connectionCheck wiring for proper polarity and secure connections. Verify DIP switch address setting matches panel configuration. Test sensor on another base or replace. Ensure sensor is properly seated in the base.
Trouble signal from baseSensor fault; Wiring issue; Environmental factors (e.e., excessive dust)Inspect sensor for damage or contamination. Check wiring. Clean sensor and base. If issue persists, replace sensor or consult technician.
Base appears loose after installationການຕິດຕັ້ງທີ່ບໍ່ຖືກຕ້ອງRe-secure the base to the electrical box or mounting bracket, ensuring all screws are tightened.

ການຮັບປະກັນແລະການສະຫນັບສະຫນູນ

For information regarding the warranty of your Simplex 4098-9792 SSD Sensor Base, please refer to the warranty documentation provided at the time of purchase or contact Simplex customer support directly. Warranty terms typically cover manufacturing defects under normal use conditions.

For technical support, service, or to report issues not covered in this manual, please contact your authorized Simplex distributor or a certified fire alarm technician. Providing your product model number (4098-9792) and a detailed description of the issue will help expedite support.

ຂໍ້ມູນຕິດຕໍ່:
Please refer to the official Simplex website or your purchase documentation for the most current contact details for customer service and technical support.

ເອກະສານທີ່ກ່ຽວຂ້ອງ - 4098-9792

ກ່ອນview Simplex TrueAlarm Analog Sensors: Photoelectric and Heat Datasheet
Comprehensive datasheet for Simplex TrueAlarm Analog Sensors, detailing photoelectric and heat models, standard bases, and accessories. Includes features, intelligent data evaluation, sensor specifications, mounting references, and product selection charts for fire alarm systems.
ກ່ອນview Simplex 4098-9019 IDNet Addressable Beam Detector Wiring and FACP Programming Guide
ຄູ່ມືທີ່ສົມບູນແບບສໍາລັບການສາຍໄຟແລະການຂຽນໂປຼແກຼມ Simplex 4098-9019 IDNet Addressable Beam Detector system with Simplex Fire Alarm Panels (FACPs). ກວມເອົາຄວາມເຂົ້າກັນໄດ້, ຂໍ້ມູນສະເພາະໄຟຟ້າ, ທີ່ຢູ່, ແລະການດໍາເນີນງານກະດານ.
ກ່ອນview ຄູ່ມືການຕິດຕັ້ງ Simplex 4008/4006-9801 ແຫຼ່ງຈ່າຍໄຟຂະຫຍາຍ (EPS)
ຄຳແນະນຳໃນການຕິດຕັ້ງສຳລັບແຫຼ່ງຈ່າຍໄຟຂະຫຍາຍ (EPS) Simplex 4008/4006-9801, ລາຍລະອຽດການຕິດຕັ້ງ, ການເຊື່ອມຕໍ່ແຜງ, ສາຍໄຟ NAC, ພະລັງງານຊ່ວຍ, ແລະ ການຈັດອັນດັບ NAC ສຳລັບລະບົບເຕືອນໄພໄຟໄໝ້.
ກ່ອນview Simplex 4100ES Addressable Fire Detection and Control Panels: Features, Modules, and Specifications
ລະອຽດview of the Simplex 4100ES Series Fire Control Panels, covering features, addressable device control, module selection, system operation, and technical specifications for fire detection and alarm systems.
ກ່ອນview ເອກະສານການຊອກຄົ້ນຫາ ແລະຄວບຄຸມໄຟຂອງ Simplex 4007ES
ແຜ່ນຂໍ້ມູນລາຍລະອຽດສໍາລັບຫນ່ວຍກວດຈັບແລະຄວບຄຸມໄຟ Simplex 4007ES, ກວມເອົາ MX Digital Addressable Initiation ແລະຄວາມສາມາດແຈ້ງເຕືອນທີ່ຢູ່ໄດ້, ຄຸນສົມບັດ, ຂໍ້ມູນສະເພາະ, ແລະລາຍລະອຽດການຕິດຕັ້ງ.
ກ່ອນview Simplex 4010ES Addressable Fire Detection and Control Units: Modules and Accessories
Comprehensive guide to Simplex 4010ES Addressable Fire Detection and Control Units, detailing features, modules, accessories, specifications, and installation.