ແນະນຳ

This manual provides detailed instructions for the installation, operation, maintenance, and troubleshooting of your Fluidmaster 400ACN3P5 Toilet Fill Valve. Please read these instructions carefully before beginning installation to ensure proper function and longevity of the product.

ຂໍ້ມູນຄວາມປອດໄພ

  • Always turn off the water supply to the toilet before beginning any work.
  • ໃສ່ອຸປະກອນປ້ອງກັນສ່ວນບຸກຄົນທີ່ເຫມາະສົມ, ເຊັ່ນ: ແວ່ນຕາຄວາມປອດໄພ, ໃນລະຫວ່າງການຕິດຕັ້ງ.
  • Do not overtighten nuts or connections, as this may cause damage or leaks.
  • ຖ້າທ່ານບໍ່ແນ່ໃຈກ່ຽວກັບຂັ້ນຕອນໃດນຶ່ງ, ໃຫ້ປຶກສາກັບຊ່າງທໍ່ນ້ຳທີ່ມີຄຸນວຸດທິ.

ເນື້ອໃນຊຸດ

Your Fluidmaster 400ACN3P5 Toilet Fill Valve package typically includes:

  • Fluidmaster 400ACN3P5 Toilet Fill Valve
  • ເຕີມທໍ່
  • ເຕີມຄລິບ
  • ເຄື່ອງຊັກຜ້າ Shank
  • ລັອກຫມາກແຫ້ງເປືອກແຂງ
Fluidmaster 400ACN3P5 Toilet Fill Valve Contractor Pack

ຮູບທີ 1: Packaging for the Fluidmaster 400ACN3P5 Toilet Fill Valve. This image shows a "Three Pack" configuration. Actual package contents may vary based on the specific product variant purchased (e.g., single pack, 5-pack).

Setup: Installation Instructions

  1. ປິດການສະຫນອງນ້ໍາ: Locate the water supply valve at the base of the toilet and turn it clockwise until the water flow stops completely.
  2. ຊັກໂຄກ: Flush the toilet to drain most of the water from the tank. Hold the flush handle down to ensure as much water as possible is removed.
  3. ເອົານ້ຳທີ່ເຫຼືອອອກ: Use a sponge or towel to remove any remaining water from the toilet tank.
  4. ຕັດການເຊື່ອມຕໍ່ສາຍສະໜອງ: Disconnect the water supply line from the bottom of the old fill valve. Have a small bucket ready to catch any residual water.
  5. ເອົາວາວເຕີມນໍ້າເກົ່າອອກ: Loosen the lock nut on the underside of the toilet tank that secures the old fill valve. Remove the old fill valve from the tank.
  6. ຕິດຕັ້ງວາວເຕີມໃໝ່: Insert the new Fluidmaster 400ACN3P5 fill valve into the hole at the bottom of the toilet tank. Ensure the shank washer is properly seated on the outside of the tank.
  7. Secure Fill Valve: Hand-tighten the lock nut onto the threaded shank of the new fill valve from the underside of the tank. Do not overtighten.
  8. Connect Water Supply Line: Reconnect the water supply line to the bottom of the new fill valve. Hand-tighten, then use a wrench for a final quarter-turn, being careful not to overtighten.
  9. Attach Refill Tube: Attach one end of the refill tube to the small port on the top of the fill valve. Clip the other end of the refill tube to the overflow pipe using the refill clip, ensuring the tube is above the water level in the tank.
  10. Adjust Fill Valve Height (if applicable): Some Fluidmaster models allow for height adjustment. If your model has this feature, adjust the height so the critical level mark (C.L.) on the valve is at least 1 inch above the top of the overflow pipe.
  11. ເປີດການສະຫນອງນ້ໍາ: Slowly turn the water supply valve counter-clockwise to restore water flow to the toilet tank.
  12. ກວດ​ສອບ​ການ​ຮົ່ວ​ໄຫລ​: Carefully inspect all connections for any signs of leaks. Tighten connections slightly if necessary.
  13. ປັບລະດັບນ້ຳ: Allow the tank to fill. The water level should stop approximately 1 inch below the top of the overflow pipe. If adjustment is needed, refer to the specific instructions for your fill valve model (often involves a screw or clip adjustment on the valve itself).

ຄໍາແນະນໍາການດໍາເນີນງານ

The Fluidmaster 400ACN3P5 Toilet Fill Valve operates automatically. After each flush, the valve senses the drop in water level and opens to refill the toilet tank to the preset level. Once the desired water level is reached, the valve automatically shuts off the water flow. The refill tube ensures that a small amount of water is directed into the toilet bowl during the refill cycle, maintaining the water seal in the bowl.

ບໍາລຸງຮັກສາ

  • ການກວດກາປົກກະຕິ: Periodically inspect the fill valve for any signs of wear, cracks, or mineral buildup.
  • ທໍາຄວາມສະອາດ: If the valve appears to be operating slowly or making unusual noises, mineral deposits may be affecting its performance. Turn off the water supply, remove the cap of the fill valve (refer to specific model instructions for cap removal), and gently clean any visible debris or mineral buildup. Rinse with clean water.
  • Check Refill Tube: Ensure the refill tube is securely attached and not kinked or obstructed.

ການແກ້ໄຂບັນຫາ

ຫ້ອງນໍ້າແລ່ນຢ່າງຕໍ່ເນື່ອງ

  • Water Level Too High: Adjust the fill valve to lower the water level in the tank. The water level should be about 1 inch below the top of the overflow pipe.
  • Flapper Leak: Check the toilet flapper for proper sealing. A worn or misaligned flapper can cause water to leak into the bowl, making the fill valve run intermittently to refill the tank.
  • Refill Tube Too Low: Ensure the refill tube is clipped above the water level in the tank and not inserted directly into the overflow pipe.

Toilet Fills Slowly or Not at All

  • Water Supply Off: ກວດໃຫ້ແນ່ໃຈວ່າປ່ຽງນ້ຳໃສ່ຫ້ອງນ້ຳເປີດເຕັມແລ້ວ.
  • Obstructed Inlet: Turn off the water, disconnect the supply line, and check the fill valve's inlet screen for debris. Clean if necessary.
  • ການ​ສ້າງ​ແຮ່​ທາດ​: Follow maintenance steps to clean the fill valve mechanism.

Fill Valve Makes Noise

  • ຄວາມກົດດັນນ້ໍາ: High water pressure can sometimes cause noise. A pressure reducing valve for the whole house might be considered.
  • ຊິ້ນສ່ວນວ່າງ: Ensure all connections are secure but not overtightened.
  • ການ​ສ້າງ​ແຮ່​ທາດ​: Clean the valve as described in the maintenance section.

ຂໍ້ມູນຈໍາເພາະ

ຄຸນສົມບັດລາຍລະອຽດ
ຍີ່ຫໍ້Fluidmaster
ໝາຍເລກຕົວແບບ400ACN3P5
ວັດສະດຸທອງເຫຼືອງ
ສໍາເລັດຮູບພາຍນອກChrome-Plated Brass
ປະເພດການເຊື່ອມຕໍ່ຂາເຂົ້າກະທູ້
ຈໍານວນພອດ2
ນ້ໍາຫນັກລາຍການ3 ປອນ
ຂະໜາດສິນຄ້າ9 x 19 x 14 ນິ້ວ
UPC039961400031
ການຢັ້ງຢືນASME, NSF, ULC, UL, IAPMO, EPA, WaterSense, CE, ASSE

ຂໍ້ມູນການຮັບປະກັນ

The Fluidmaster 400ACN3P5 Toilet Fill Valve comes with a 1-year limited warranty from the date of purchase. This warranty covers defects in materials and workmanship under normal use. Please retain your proof of purchase for warranty claims. For full warranty details, please refer to the official Fluidmaster webເວັບໄຊທ໌ຫຼືຕິດຕໍ່ສະຫນັບສະຫນູນລູກຄ້າ.

ສະຫນັບສະຫນູນ

For further assistance, technical support, or to inquire about replacement parts, please visit the official Fluidmaster webເວັບໄຊ ຫຼືຕິດຕໍ່ພະແນກບໍລິການລູກຄ້າຂອງເຂົາເຈົ້າ.

Webເວັບໄຊ: www.fluidmaster.com

ບໍລິການລູກຄ້າ: Refer to the Fluidmaster webສະຖານທີ່ສໍາລັບຫມາຍເລກຕິດຕໍ່ແລະຊົ່ວໂມງຂອງການດໍາເນີນງານ.

ເອກະສານທີ່ກ່ຽວຂ້ອງ - 400ACN3P5

ກ່ອນview Fluidmaster K-400H-021 'The Everything' Toilet Tank Repair Kit Installation Guide
Comprehensive installation guide for the Fluidmaster K-400H-021 'The Everything' Toilet Tank Repair Kit. Learn how to replace your flush valve, fill valve, and other components for optimal toilet performance. Includes step-by-step instructions, troubleshooting, and warranty information.
ກ່ອນview Fluidmaster 703A5B Fill Valve Replacement Guide
ຄູ່ມືທີ່ສົມບູນແບບເພື່ອທົດແທນປ່ຽງຕື່ມ Fluidmaster 703A5B. ປະກອບມີຄໍາແນະນໍາຂັ້ນຕອນໂດຍຂັ້ນຕອນສໍາລັບການໂຍກຍ້າຍ, ການທົດແທນການປະທັບຕາ, ແລະການລ້າງສິ່ງເສດເຫຼືອ, ມີຄໍາອະທິບາຍລາຍລະອຽດຂອງແຜນວາດເພື່ອໃຫ້ຄວາມເຂົ້າໃຈທີ່ຊັດເຈນ.
ກ່ອນview Fluidmaster 400H PerforMAX Fill Valve ຄູ່ມືການຕິດຕັ້ງດ່ວນ
ຂັ້ນຕອນໂດຍຂັ້ນຕອນຄໍາແນະນໍາສໍາລັບການຕິດຕັ້ງແລະແກ້ໄຂບັນຫາຂອງປ່ຽງຫ້ອງນ້ໍາ Fluidmaster 400H PerforMAX. ລວມມີສ່ວນຫຼາຍກວ່າview, ເຄື່ອງມືທີ່ຈໍາເປັນ, ແລະຂໍ້ມູນການຮັບປະກັນ.
ກ່ອນview ຄູ່ມືການຕິດຕັ້ງ Fluidmaster 540T Single Flush Valve | ສ້ອມແປງ ແລະປ່ຽນສ່ວນຫ້ອງນ້ຳ
ຂັ້ນຕອນໂດຍຂັ້ນຕອນຄໍາແນະນໍາການຕິດຕັ້ງສໍາລັບ Fluidmaster 540T Single Flush Valve. ຮຽນ​ຮູ້​ວິ​ທີ​ການ​ປ່ຽນ​ປ່ຽງ​ຊັກ​ຂອງ​ຫ້ອງ​ນ​້​ໍ​ຂອງ​ທ່ານ​ໄດ້​ຢ່າງ​ງ່າຍ​ດາຍ​ແລະ​ຄວາມ​ຫມັ້ນ​ໃຈ​. ລວມມີຂໍ້ມູນການເຕືອນໄພ ແລະ ການຮັບປະກັນ.
ກ່ອນview Fluidmaster K-400A-023 Mansfield Repair Kit Quick Install Guide
This quick installation guide provides clear, step-by-step instructions for fitting the Fluidmaster K-400A-023 Mansfield Repair Kit. It is designed to help users efficiently replace toilet tank components, ensuring optimal performance and water conservation.
ກ່ອນview ຄູ່ມືການຕິດຕັ້ງລະບົບ Fluidmaster DUO FLUSH™
ຄູ່ມືການຕິດຕັ້ງທີ່ສົມບູນແບບສໍາລັບລະບົບ Fluidmaster DUO FLUSH™, ລວມທັງຊິ້ນສ່ວນຕ່າງໆview, ຄໍາແນະນໍາຂັ້ນຕອນໂດຍຂັ້ນຕອນສໍາລັບການຕິດຕັ້ງ DUO FLUSH™ Valve, PerforMAX™ Fill Valve, Dual Action Handle, ແລະຄໍາແນະນໍາການແກ້ໄຂບັນຫາ.