This manual provides essential information for the safe and efficient installation, operation, and maintenance of the Uponor Thermal Actuator ST230, 230V, Model 1013006. Please read these instructions carefully before proceeding with installation or use. Retain this manual for future reference.

2. ຜະລິດຕະພັນເກີນview

The Uponor Thermal Actuator ST230, 230V, Model 1013006 is designed for controlling the return valves on Uponor Vario S manifolds in underfloor heating systems. It operates on 230 Volts and features a screw connection IG M 30 x 1.5, a stroke indicator, and a 1.0-meter connection cable with wire end ferrules. The unit is splash-proof with an IP54 rating and is CE and RoHS certified.

Uponor Thermal Actuator ST230, 230V, Model 1013006

ຮູບທີ 2.1: Uponor Thermal Actuator ST230, 230V, Model 1013006. This image shows the blue housing of the actuator with the Uponor logo and the grey screw connection base.

3. ຂໍ້ມູນຄວາມປອດໄພ

  • Installation and electrical connections must be performed by a qualified electrician or authorized personnel in accordance with local regulations and standards.
  • Ensure the main power supply is disconnected before performing any installation, maintenance, or troubleshooting.
  • Do not open the actuator housing. There are no user-serviceable parts inside.
  • Protect the device from direct water spray or immersion, despite its splash-proof rating.
  • Use only genuine Uponor components and accessories.

4. ການຕິດຕັ້ງແລະການຕິດຕັ້ງ

The thermal actuator is designed for easy mounting on Uponor Vario S manifold return valves. Follow these steps for proper installation:

  1. Ensure the heating system is depressurized and the manifold valves are in the correct position for actuator mounting.
  2. Carefully screw the actuator onto the valve connection (IG M 30 x 1.5) by hand until it is securely fastened. Do not overtighten.
  3. Connect the 230V electrical cable to the appropriate control unit or thermostat terminals. The cable is 0.75 mm² x 1.0 m and comes with wire end ferrules for secure connection.
  4. Verify all connections are secure and correctly wired according to the system's electrical diagram.
Diagram of Uponor Thermal Actuator with cable

ຮູບທີ 4.1: Diagram showing the Uponor Thermal Actuator with its integrated connection cable. This illustrates the actuator's form factor and cable exit point.

Dimensional drawing of Uponor Thermal Actuator

ຮູບທີ 4.2: Dimensional drawing of the Uponor Thermal Actuator, indicating key measurements (do, h, G) for installation planning. 'do' represents the outer diameter, 'h' the height, and 'G' the thread size.

5. ຄໍາແນະນໍາການດໍາເນີນງານ

The Uponor Thermal Actuator operates automatically in conjunction with a room thermostat or heating control system. When the control system signals a demand for heat, the actuator receives power, causing its internal element to expand and open the valve. When the heat demand is met, power is removed, and the actuator cools, closing the valve.

  • Stroke Indicator: The actuator is equipped with a stroke indicator, typically a small pin or window, which visually confirms the valve's open or closed position. Observe this indicator to verify proper operation.
  • ການ​ດໍາ​ເນີນ​ງານ​ເບື້ອງ​ຕົ້ນ​: After installation and power-up, allow a short period for the actuator to respond to the control signal and fully open or close the valve.

6. ບໍາລຸງຮັກສາ

The Uponor Thermal Actuator ST230, 230V, Model 1013006 is designed for maintenance-free operation. No regular servicing or lubrication is required.

  • Keep the exterior of the actuator clean and free from dust or debris. Use a soft, dry cloth for cleaning.
  • ຢ່າໃຊ້ເຄື່ອງເຮັດຄວາມສະອາດຂັດຫຼືສານລະລາຍ.
  • Periodically check the electrical connections for any signs of wear or damage.

7. ການແກ້ໄຂບັນຫາ

If the thermal actuator is not functioning as expected, consider the following:

  • Actuator not opening/closing:
    • Check if the control system (thermostat) is calling for heat.
    • Verify that the actuator is receiving 230V power.
    • Ensure electrical connections are secure and correct.
    • Confirm the actuator is correctly screwed onto the valve.
  • No visible movement of stroke indicator:
    • Allow sufficient time for the actuator to react (thermal actuators have a delay).
    • Check power supply and control signal.

If issues persist after checking these points, contact qualified service personnel.

8. ຂໍ້ມູນຈໍາເພາະ

Uponor Thermal Actuator ST230, 230V, Model 1013006 Technical Data Sheet

ຮູບທີ 8.1: Technical data sheet for the Uponor Thermal Actuator ST230, 230V, Model 1013006, providing detailed specifications and contact information.

ຂໍ້ມູນຈໍາເພາະມູນຄ່າ
ຍີ່ຫໍ້Uponor
ໝາຍເລກຕົວແບບ1013006
ຜູ້ຜະລິດUponor
ຂະໜາດສິນຄ້າ (L x W x H)5 x 5 x 7.5 cm
ນ້ຳໜັກ120 ກຣາມ
ສະບັບtage230 ໂວນ
ສູງສຸດ Voltage230 ໂວນ
ປະເພດຕົວເຊື່ອມຕໍ່ສະປາ
ວັດສະດຸຕິດຕໍ່ສະແຕນເລດ
ວັດສະດຸ insulationໂພລີໂອລິນ
ປະເພດ TerminalSpade Terminal
ຂໍ້ກຳນົດທີ່ສອດຄ່ອງກັບCE, RoHS
ປະເທດຕົ້ນກໍາເນີດເຢຍລະມັນ
ລະຫັດມາດຕາສາກົນ (EAN)04021598002937
ສາຍເຊື່ອມຕໍ່0.75 mm² x 1.0 m, without plug, with wire end ferrules
ຫ້ອງຮຽນປົກປ້ອງIP54 (ກັນນໍ້າກະແຈກກະຈາຍ)
ການເຊື່ອມຕໍ່ວາວScrew connection IG M 30 x 1.5
ຄຸນສົມບັດຕົວຊີ້ວັດເສັ້ນເລືອດຕັນໃນ

9. ການຮັບປະກັນແລະການສະຫນັບສະຫນູນ

Uponor products are manufactured to high-quality standards. For specific warranty terms and conditions, please refer to the documentation provided with your purchase or contact Uponor directly. Information regarding spare parts availability is not provided in the product specifications.

ຂໍ້ມູນຕິດຕໍ່:

Uponor GmbH

ອຸດ​ສາ​ຫະ​ກໍາ 56

97437 Hassfurt

ເຢຍລະມັນ

ໂທລະສັບ: +4932210090856

ອີເມວ: Kundenservice@uponor.com

Webເວັບໄຊ: www.uponor.com/de-de

ເອກະສານທີ່ກ່ຽວຂ້ອງ - 1013006

ກ່ອນview Uponor Underfloor Heating and Cooling: Planning Information Guide
This comprehensive planning guide from Uponor details underfloor heating and cooling systems, covering technical specifications, design criteria, installation procedures, and hydraulic balancing for optimal climate control solutions.
ກ່ອນview ຄູ່ມືການຕິດຕັ້ງ ແລະ ເຕັກນິກຂອງຕົວກະຕຸ້ນ Uponor Vario / Vario PLUS
ຄູ່ມືທີ່ຄົບຖ້ວນສົມບູນກ່ຽວກັບຕົວກະຕຸ້ນ Uponor Vario ແລະ Vario PLUS, ເຊິ່ງກວມເອົາການຕິດຕັ້ງ, ການດຳເນີນງານ, ຄຸນສົມບັດຕ່າງໆເຊັ່ນ 'First-Open', ແລະລາຍລະອຽດດ້ານເຕັກນິກສຳລັບລະບົບ HVAC.
ກ່ອນview ຄູ່ມືການຕິດຕັ້ງ Uponor Classic
ຄູ່ມືນີ້ໃຫ້ຄໍາແນະນໍາການຕິດຕັ້ງຢ່າງລະອຽດສໍາລັບລະບົບ Uponor Classic, ລວມທັງການວາງທໍ່, ການເຊື່ອມຕໍ່ manifold, ແລະການທົດສອບຄວາມກົດດັນ. ມັນກວມເອົາຂັ້ນຕອນທີ່ຈໍາເປັນສໍາລັບການຕິດຕັ້ງທີ່ປະສົບຜົນສໍາເລັດແລະປະສິດທິພາບຂອງລະບົບຄວາມຮ້ອນຊັ້ນ Uponor Classic.
ກ່ອນview ຕົວກະຕຸ້ນການຕິດຕັ້ງ Uponor Vario: ຄູ່ມືການຕິດຕັ້ງ ແລະ ລາຍລະອຽດດ້ານເຕັກນິກ
ຄູ່ມືທີ່ສົມບູນແບບກ່ຽວກັບການຕິດຕັ້ງ ແລະ ການນຳໃຊ້ຕົວກະຕຸ້ນການຕິດຕັ້ງ Uponor Vario, ລວມທັງລາຍລະອຽດທາງເຕັກນິກລະອຽດ, ຂໍ້ມູນຄວາມເຂົ້າກັນໄດ້ ແລະ ຄຳແນະນຳດ້ານຄວາມປອດໄພສຳລັບລະບົບ HVAC.
ກ່ອນview Uponor Siccus Mini: Dry Underfloor Heating and Cooling System Technical Specifications
Comprehensive technical information for the Uponor Siccus Mini low-height dry underfloor heating and cooling system. Covers system description, benefits, components, planning, installation, and detailed technical specifications for residential modernization.
ກ່ອນview Uponor Combi Port E-Hybrid Quick Guide - Installation and Operation
This quick guide provides essential information for the installation and operation of the Uponor Combi Port E-Hybrid heat interface unit. It covers general safety, component identification, hydraulic and electrical installation, filling, flushing, testing, and visual inspection procedures.