Riello 3007771/RI

Riello Gulliver RG1 Oil Burner Pump Instruction Manual

Model: 3007771/RI

ແນະນຳ

This instruction manual provides essential information for the safe and correct use, installation, and maintenance of the Riello Gulliver RG1 Oil Burner Pump, model 3007771/RI. This pump is designed for use with Riello RDB, Unit, Gulliver RG0 (358T1 - 359T1 - 360T1), Gulliver RG1 (363T1), and Gulliver RG2 (377T1) series oil burners. Please read this manual thoroughly before any operation or service.

ຂໍ້ມູນຄວາມປອດໄພທີ່ສໍາຄັນ

WARNING: Risk of injury or equipment damage.

The replacement of spare parts on boilers or boiler burners must be carried out with extreme caution. To ensure the safety and proper functioning of your appliance, it is strongly recommended that this operation be performed by a qualified technician. Incorrect installation can lead to risks of malfunction, safety hazards, and potential damage to the heating system or property.

This product is sold in its original manufacturer's packaging and has not undergone any modifications. Due to the nature of this product, professional installation is highly recommended.

ສິນຄ້າເກີນview

The Riello Gulliver RG1 Oil Burner Pump (model 3007771/RI) is a critical component for various Riello oil burners. It is designed to deliver fuel efficiently and reliably to the burner. This specific pump is supplied without a coil, which must be acquired separately if needed.

Riello Gulliver RG1 Oil Burner Pump

ຮູບພາບ 1: ດ້ານໜ້າ view of the Riello Gulliver RG1 Oil Burner Pump. The pump features a metallic housing with visible hex screws and a central brass shaft. The front plate is marked "R.B.L." with directional arrows, indicating flow. This image shows the robust construction and key external features of the pump.

ຂໍ້ມູນຈໍາເພາະ

ຄຸນສົມບັດລາຍລະອຽດ
ຜູ້ຜະລິດRiello
ໝາຍເລກຕົວແບບ3007771/RI
ຄວາມເຂົ້າກັນໄດ້Riello RDB, Unit, Gulliver RG0 (358T1 - 359T1 - 360T1), Gulliver RG1 (363T1), Gulliver RG2 (377T1)
ເສັ້ນຜ່າສູນກາງ Shaft8 ມມ
ພືດຫມູນວຽນD (Right)
ຄວາມກົດດັນ12 ບາ
ສູນກາງ32 ມມ
d_bit36
Coil IncludedNo (delivered without coil)

ການຕິດຕັ້ງ

As highlighted in the safety information, the installation of the Riello Gulliver RG1 pump requires specialized knowledge and should only be performed by a qualified and certified technician. Incorrect installation can lead to severe operational issues, safety hazards, and void any warranties.

General steps for a qualified technician typically include:

  1. ການຕັດການເຊື່ອມຕໍ່ໄຟຟ້າ: Ensure the main power supply to the burner and heating system is completely disconnected and locked out.
  2. Fuel Line Isolation: Close fuel supply valves to prevent spills.
  3. Old Pump Removal: Carefully disconnect fuel lines and electrical connections from the old pump. Remove mounting bolts and extract the old pump.
  4. ການຕິດຕັ້ງປັ໊ມໃໝ່: Mount the new Riello Gulliver RG1 pump securely, ensuring proper alignment with the burner shaft.
  5. ການເຊື່ອມຕໍ່: Reconnect fuel lines, ensuring all fittings are tight and leak-free. Reconnect electrical wiring according to the burner's wiring diagram.
  6. ການແຕ່ງຕົວ: Follow the burner manufacturer's instructions for priming the fuel system to remove air.
  7. Leak Check & Testing: Restore power and carefully check for any fuel leaks. Test the burner operation, monitoring fuel pressure and combustion.

Always refer to the specific installation instructions provided with your Riello burner model for detailed steps and safety precautions.

ການດໍາເນີນງານ

The Riello Gulliver RG1 pump operates as part of the oil burner system, drawing fuel from the tank and delivering it at a precise pressure to the nozzle for atomization and combustion. Once installed correctly, the pump's operation is typically automatic, controlled by the burner's control unit.

ບໍາລຸງຮັກສາ

Proper maintenance is crucial for the longevity and efficient operation of your Riello Gulliver RG1 pump and the entire heating system. Maintenance should be performed by a qualified technician.

ການແກ້ໄຂບັນຫາ

If you experience issues with your oil burner, the pump may be a contributing factor. Always consult a qualified technician for diagnosis and repair.

ບັນຫາສາເຫດທີ່ເປັນໄປໄດ້Action (for qualified technician)
Burner ລົ້ມເຫລວNo fuel delivery, low fuel pressure, air in fuel lines, clogged filter.Check fuel level, prime pump, inspect/replace filter, check pump pressure.
Burner ຮອບວຽນເປີດ / ປິດເລື້ອຍໆInconsistent fuel pressure, air in system.Check for air leaks, verify pump pressure stability.
Oil leaks from pumpDamaged shaft seal, loose fittings.Inspect and replace seals, tighten connections.
ສຽງຜິດປົກກະຕິຈາກປັ໊ມAir in system, worn bearings, cavitation.Bleed air, inspect pump internals for wear.

Do not attempt to repair the pump yourself if you are not a qualified technician. Contact a professional for all troubleshooting and repair needs.

ການຮັບປະກັນແລະການສະຫນັບສະຫນູນ

Information regarding specific warranty terms for the Riello Gulliver RG1 pump (model 3007771/RI) is not available in this document. Please refer to your purchase documentation or contact your supplier or a certified Riello service center for warranty details and technical support.

For spare parts availability, the provided information states "Information indisponible sur les pièces détachées" (Information unavailable on spare parts). It is recommended to contact Riello directly or an authorized distributor for spare part inquiries.

ເອກະສານທີ່ກ່ຽວຂ້ອງ - 3007771/RI

ກ່ອນview Riello Gulliver RG2F Oil Burner ບັນຊີລາຍຊື່ແລະແຜນວາດ
ລາຍ​ການ​ອາ​ໄຫຼ່​ລາຍ​ລະ​ອຽດ​ແລະ​ແຜນ​ວາດ​ອົງ​ປະ​ກອບ​ສໍາ​ລັບ​ການ Riello Gulliver RG2F ຫມໍ້​ໄຟ​ນ​້​ໍາ​ມັນ​ແສງ (Model 377T1​, ລະ​ຫັດ 3737770​)​, ລວມ​ທັງ​ການ​ເລກ​ສ່ວນ​ແລະ​ຄໍາ​ອະ​ທິ​ບາຍ​ພາ​ສາ​ອັງ​ກິດ​.
ກ່ອນview Priročnik za namestitev, uporabo ໃນ vzdrževanje gorilnika RIELLO Gulliver RG1NR na plinsko olje
Ta dokument vsebuje podrobna navodila za namestitev, uporabo, vzdrževanje in odpravljanje napak enostopenjskega gorilnika RIELLO Gulliver RG1NR na plinsko olje, vključno s tehničnimi podatki, postiodvosti varnost. težav.
ກ່ອນview Riello 40 Series Residential Oil Burners F3 & F5 ຄູ່ມືການຕິດຕັ້ງ
ຄູ່ມືນີ້ໃຫ້ຄໍາແນະນໍາການຕິດຕັ້ງຢ່າງລະອຽດສໍາລັບ Riello 40 Series Residential Oil Burners, ແບບ F3 ແລະ F5. ມັນກວມເອົາການກໍານົດອົງປະກອບ, ການຕິດຕັ້ງ, ການຕິດຕັ້ງ, ການເຊື່ອມຕໍ່ໄຟຟ້າ, ການຈັດວາງ nozzle, ແລະຂັ້ນຕອນການປັບ. ຄູ່ມືແມ່ນມີຈຸດປະສົງສໍາລັບຄໍາຮ້ອງສະຫມັກ retrofit ແລະປະກອບມີຂໍ້ມູນດ້ານວິຊາການ, ຂໍ້ມູນສະເພາະ, ແລະລາຍການອາໄຫຼ່.
ກ່ອນview Riello 40 BF Single Stage Operation Oil Burner Installation and Operating Manual
Comprehensive installation and operating manual for the Riello 40 BF single-stage oil burner, covering technical specifications, installation procedures, wiring diagrams, troubleshooting, and spare parts.
ກ່ອນview Riello 40 Series F3 & F5 Residential Oil Burner Installation Manual
Comprehensive installation manual for Riello 40 Series residential oil burners, models F3 and F5. Covers technical data, component identification, setup, mounting, electrical connections, oil line configuration, pump purge, adjustments, and spare parts.
ກ່ອນview Riello 40 G10 Light Oil Burner Installation and Maintenance Manual
This document provides comprehensive installation, use, and maintenance instructions for the Riello 40 G10 light oil burner. It includes technical data, diagrams, electrical wiring schematics, and combustion adjustment procedures.