1. ບົດແນະນຳ
This manual provides essential instructions for the safe and effective operation of the Hioki 3030-10 HiTester Analog Multimeter. This device is an average-sensing, manual-ranging meter designed for measuring voltage, resistance, and current in various electrical testing applications. Please read this manual thoroughly before use and retain it for future reference.
2. ຂໍ້ມູນຄວາມປອດໄພ
To ensure safe operation and prevent damage to the device, observe the following safety precautions:
- The meter is designed to meet International Electrotechnical Commission (IEC) safety standard 61010.
- It is certified for Category III installations up to 600V, suitable for use with enclosed building circuit installations (e.g., service panel parts, branch circuits, fixed installations connected directly to AC power supply).
- A 0.5-amp/250V fuse is installed to protect the operator from electric shock due to transient voltage. Do not bypass or use an incorrect fuse.
- Always select the appropriate measurement range before connecting the test leads to the circuit.
- ຢ່າເກີນອັດຕາຄ່າປ້ອນຂໍ້ມູນສູງສຸດສຳລັບໜ້າທີ່ໃດໆ.
- Inspect test leads for damage before each use. Replace if insulation is compromised.
- The meter is designed to withstand falls of up to 1 meter onto hardwood or concrete. However, avoid dropping the device.
3. ເນື້ອໃນຊຸດ
ກວດສອບວ່າມີລາຍການທັງຫມົດ:
- Hioki 3030-10 HiTester Analog Multimeter
- Detachable Test Leads (Red and Black)
- ກະເປົາຖື
- ຄູ່ມືຜູ້ໃຊ້ (ເອກະສານນີ້)
4. ຜະລິດຕະພັນເກີນview ແລະຄຸນສົມບັດ

ຮູບທີ 1: Hioki 3030-10 HiTester Analog Multimeter. The image displays the multimeter unit, its protective carrying case, and the red and black test leads. The multimeter features a clear analog display with multiple scales for various measurements, a central rotary switch for function and range selection, and input jacks for the test leads.
The Hioki 3030-10 is an analog multimeter designed for reliable electrical measurements. Key features include:
- ຈໍສະແດງຜົນແບບອະນາລັອກ: Provides a clear, real-time indication of measurements, useful for observing trends and fluctuations.
- Manual Ranging: Requires the user to select the appropriate measurement range for precision.
- Average-Sensing: Delivers accurate readings for linear loads with undistorted waveforms.
- ຟັງຊັນການວັດແທກ: ມາດຕະການ DC/AC voltage, ກະແສໄຟຟ້າ DC, ແລະຄວາມຕ້ານທານ.
- Battery Test Feature: Determines charge level for 1.5V batteries.
- LED Test Function: Allows testing of LED lights.
- Temperature Measurement Capability: Requires a separately sold thermistor probe.
- ການປະຕິບັດຕາມຄວາມປອດໄພ: Meets IEC 61010, CAT III 600V safety standards.
- ການອອກແບບທົນທານ: Engineered to withstand drops up to 1 meter.
5. ຕັ້ງຄ່າ
5.1 ການຕິດຕັ້ງຫມໍ້ໄຟ
The Hioki 3030-10 requires two AAA batteries for operation. To install or replace batteries:
- Ensure the multimeter is turned OFF (rotary switch set to 'OFF').
- ຊອກຫາຝາປິດຊ່ອງໃສ່ຫມໍ້ໄຟຢູ່ດ້ານຫຼັງຂອງໜ່ວຍ.
- Open the cover and insert two AAA batteries, observing the correct polarity (+/-) as indicated inside the compartment.
- ປິດຝາປິດຝາຫມໍ້ໄຟ.
5.2 ການເຊື່ອມຕໍ່ສາຍທົດສອບ
Connect the detachable test leads to the multimeter:
- Insert the black test lead into the "COM" (common) input jack.
- Insert the red test lead into the "VΩmA" input jack for voltage, resistance, and current measurements.
- ໃຫ້ແນ່ໃຈວ່າການເຊື່ອມຕໍ່ແມ່ນແໜ້ນໜາກ່ອນທີ່ຈະດໍາເນີນການວັດແທກໃດໆ.
6. ຄໍາແນະນໍາການດໍາເນີນງານ
The Hioki 3030-10 is a manual-ranging multimeter. Always select the appropriate function and range using the rotary switch before making a measurement.
6.1 DC Voltage ການວັດແທກ (V)
- ຕັ້ງສະວິດ rotary ເປັນ DC Vol ທີ່ຕ້ອງການtage (V) range (e.g., 0.3V, 3V, 12V, 30V, 120V, 300V, 600V). Start with the highest range if the voltage ແມ່ນບໍ່ຮູ້ຈັກ.
- ເຊື່ອມຕໍ່ສາຍທົດສອບສີແດງເຂົ້າກັບດ້ານບວກ (+) ຂອງວົງຈອນ ແລະ ສາຍທົດສອບສີດຳເຂົ້າກັບດ້ານລົບ (-).
- ອ່ານ voltage value from the appropriate DCV scale on the analog display.
6.2 AC Voltage Measurement (~V)
- ຕັ້ງຄ່າສະຫຼັບ rotary ກັບ AC Vol ທີ່ຕ້ອງການtage (~V) range (e.g., 12V, 30V, 120V, 300V, 600V). Start with the highest range if the voltage ແມ່ນບໍ່ຮູ້ຈັກ.
- ເຊື່ອມຕໍ່ຕົວນໍາການທົດສອບໃນທົ່ວ AC voltage ແຫຼ່ງ.
- ອ່ານ voltage value from the appropriate ACV scale on the analog display.
6.3 DC Current Measurement (A)
ຂໍ້ຄວນລະວັງ: ເຊື່ອມຕໍ່ມັລຕິມີເຕີແບບອະນຸກົມກັບວົງຈອນສະເໝີເມື່ອວັດແທກກະແສໄຟຟ້າ. ຢ່າເຊື່ອມຕໍ່ມັນແບບຂະໜານກັນຂ້າມກະແສໄຟຟ້າtage ແຫຼ່ງ.
- Set the rotary switch to the desired DC Current (A) range (e.g., 60µA, 30mA, 300mA). Start with the highest range if the current is unknown.
- Break the circuit and connect the multimeter in series, ensuring the current flows through the meter.
- Read the current value from the appropriate DCA scale on the analog display.
6.4 ການວັດແທກຄວາມຕ້ານທານ (Ω)
ຂໍ້ຄວນລະວັງ: ໃຫ້ແນ່ໃຈວ່າວົງຈອນຖືກຕັດພະລັງງານກ່ອນທີ່ຈະວັດແທກຄວາມຕ້ານທານ.
- Set the rotary switch to the desired Resistance (Ω) range (e.g., x1, x10, x100, x1k).
- Before measuring, short the test leads together and adjust the "Ω ADJ" knob (if present) to zero the meter.
- ເຊື່ອມຕໍ່ຕົວນໍາການທົດສອບໃນທົ່ວອົງປະກອບທີ່ຈະວັດແທກ.
- Read the resistance value from the Ω scale on the analog display and multiply by the selected range multiplier.
6.5 Battery Test (BATT 1.5V)
- Set the rotary switch to the "BATT 1.5V" position.
- Connect the red test lead to the positive (+) terminal of the 1.5V battery and the black test lead to the negative (-) terminal.
- Read the battery charge level from the "BATT" scale on the analog display.
6.6 LED Test (LED)
- Set the rotary switch to the "LED" position.
- Connect the test leads to the LED. Observe polarity; if the LED does not light, reverse the leads.
- A lit LED indicates functionality.
6.7 ການວັດແທກອຸນຫະພູມ (TEMP)
This function requires a separately purchased thermistor probe. Refer to the thermistor probe's manual for specific connection and operation instructions.
- Set the rotary switch to the "TEMP" position.
- Connect the thermistor probe to the designated input jacks.
- Read the temperature from the "TEMP(°C)" scale on the analog display.
7. ບໍາລຸງຮັກສາ
7.1 ການທໍາຄວາມສະອາດ
ເຊັດແມັດຄasing ມີອ່ອນ, damp cloth. Do not use abrasive cleaners or solvents. Ensure the device is off and disconnected from all circuits before cleaning.
7.2 ການທົດແທນຟິວ
If the current measurement function ceases to operate, the fuse may need replacement. The Hioki 3030-10 uses a 0.5-amp/250V fuse. Always replace with a fuse of the identical type and rating.
- ໃຫ້ແນ່ໃຈວ່າມັນຕິມີເຕີປິດຢູ່ ແລະ ສາຍທົດສອບຖືກຖອດອອກແລ້ວ.
- Refer to the device's internal diagram (if available) or contact customer support for instructions on accessing the fuse compartment.
- Carefully remove the old fuse and insert the new 0.5A/250V fuse.
- Reassemble the meter securely.
7.3 ການເກັບຮັກສາ
When not in use, store the multimeter in its carrying case in a cool, dry place, away from direct sunlight and extreme temperatures. Remove batteries if storing for extended periods to prevent leakage.
8. ການແກ້ໄຂບັນຫາ
If the multimeter does not function as expected, consider the following:
- ບໍ່ມີຈໍສະແດງຜົນ/ພະລັງງານ: ກວດເບິ່ງການຕິດຕັ້ງແບດເຕີລີ່ແລະໃຫ້ແນ່ໃຈວ່າແບດເຕີຣີບໍ່ຫມົດໄປ. ປ່ຽນແທນຖ້າຈໍາເປັນ.
- ການອ່ານທີ່ບໍ່ຖືກຕ້ອງ:
- ໃຫ້ແນ່ໃຈວ່າໄດ້ເລືອກຟັງຊັນ ແລະ ຂອບເຂດທີ່ຖືກຕ້ອງສຳລັບການວັດແທກ.
- ກວດສອບວ່າສາຍທົດສອບໄດ້ເຊື່ອມຕໍ່ຢ່າງຖືກຕ້ອງ ແລະ ບໍ່ເສຍຫາຍ.
- For resistance measurements, ensure the circuit is de-energized and the meter is zeroed.
- Current Function Not Working: Check the internal fuse (refer to Section 7.2).
- Needle Not Moving: Ensure the meter is powered on and the test leads are making good contact with the circuit. Check for open circuits.
If problems persist after attempting these steps, contact Hioki customer support for further assistance.
9. ຂໍ້ມູນຈໍາເພາະ
| ພາລາມິເຕີ | ມູນຄ່າ |
|---|---|
| ໝາຍເລກຕົວແບບ | 3030-10 |
| ປະເພດການວັດແທກ | Analog Multimeter (Average-Sensing, Manual-Ranging) |
| ຊິງຕັນດີຊີ Voltage ຊ່ວງ | 0.3V, 3V, 12V, 30V, 120V, 300V, 600V |
| AC Voltage ຊ່ວງ | 12V, 30V, 120V, 300V, 600V |
| DC Current Ranges | 60µA, 30mA, 300mA |
| ຊ່ວງການຕໍ່ຕ້ານ | x1, x10, x100, x1k (Max 3MΩ) |
| ການທົດສອບຫມໍ້ໄຟ | ຫມໍ້ໄຟ 1.5V |
| ການປ້ອງກັນຟິວ | 0.5A / 250V |
| ມາດຕະຖານຄວາມປອດໄພ | IEC 61010, CAT III 600V |
| ແຫຼ່ງພະລັງງານ | 2 x ຫມໍ້ໄຟ AAA (ບໍ່ລວມ) |
| ນ້ໍາຫນັກລາຍການ | 150 g |
| ຂະໜາດສິນຄ້າ (L x W x H) | 15.75 x 15.49 x 5.84 cm |
| ການດໍາເນີນງານ Voltage (Min.) | 0.3 ໂວນ (DC) |
| ລະດັບອຸນຫະພູມສູງສຸດ | 150 ອົງສາ Celsius |