Finder 22.32.0.024.4320

ຄູ່ມືຜູ້ໃຊ້ຄອນແທັກເຕີແບບໂມດູນ Finder 22.32.0.024.4320

24V AC/DC Coil, DPST-NO 25A, LED & Mechanical Indicator

1. ການແນະນໍາ ແລະຫຼາຍກວ່າview

This manual provides essential information for the safe and effective installation, operation, and maintenance of the Finder 22.32.0.024.4320 Modular Contactor. This device is designed for controlling electrical loads in various industrial and commercial applications. It features a 24V AC/DC coil, DPST-NO (Double Pole Single Throw - Normally Open) contacts rated at 25A, and integrated LED and mechanical indicators for status monitoring.

Please read this manual thoroughly before attempting any installation or operation to ensure proper functionality and safety.

2. ຂໍ້ມູນຄວາມປອດໄພ

ຄຳເຕືອນ: ອັນຕະລາຍຈາກໄຟຟ້າຊອດ. ການຕິດຕັ້ງແລະການບໍາລຸງຮັກສາຄວນຈະຖືກປະຕິບັດໂດຍບຸກຄະລາກອນທີ່ມີຄຸນວຸດທິເທົ່ານັ້ນ.

  • Always disconnect power to the circuit before installing, servicing, or removing the contactor.
  • ໃຫ້ແນ່ໃຈວ່າສາຍໄຟທັງຫມົດປະຕິບັດຕາມລະຫັດໄຟຟ້າທ້ອງຖິ່ນແລະແຫ່ງຊາດ.
  • ກວດ​ສອບ voltage ແລະ ການຈັດອັນດັບໃນປະຈຸບັນຂອງຄອນແທັກເຕີກົງກັບຄວາມຕ້ອງການຂອງແອັບພລິເຄຊັນ.
  • ຢ່າໃຊ້ contactor ຖ້າມັນປະກົດວ່າເສຍຫາຍ.
  • ໃຊ້ອຸປະກອນປ້ອງກັນສ່ວນບຸກຄົນທີ່ເຫມາະສົມ (PPE) ໃນລະຫວ່າງການຕິດຕັ້ງແລະບໍາລຸງຮັກສາ.

3. ຄຸນລັກສະນະຂອງຜະລິດຕະພັນ

  • ຕົວແບບ: Finder 22.32.0.024.4320
  • Coil Voltage: 24V AC / DC
  • ການຕັ້ງຄ່າການຕິດຕໍ່: DPST-NO (Double Pole Single Throw - Normally Open)
  • ການຈັດອັນດັບການຕິດຕໍ່: 25A
  • ເອກະສານຕິດຕໍ່: AGSNO2 (Silver Tin Oxide) for high switching capacity and durability.
  • ຕົວຊີ້ວັດ: Integrated LED for coil status and mechanical indicator for contact position.
  • ການຕິດຕັ້ງ: DIN Rail Mountable for easy installation in control panels.
  • ການອອກແບບ: Modular and compact, suitable for space-constrained applications.
  • ໂໝດການໃຊ້ງານ: Automatic (controlled by coil energization).

4. ການຕິດຕັ້ງແລະການຕິດຕັ້ງ

4.1 ການຕິດຕັ້ງ

The Finder 22.32.0.024.4320 contactor is designed for DIN rail mounting. To install:

  1. Ensure the DIN rail is securely fastened within the enclosure.
  2. Hook the top edge of the contactor onto the DIN rail.
  3. Press the bottom edge of the contactor firmly until it clicks into place on the DIN rail.
  4. Verify the contactor is securely attached and does not wobble.

4.2 ການເຊື່ອມຕໍ່ສາຍໄຟ

Refer to the wiring diagram and terminal markings on the contactor for correct connections. The contactor has two main sets of terminals:

  • ຂົ້ວຕໍ່ຂົດລວດ (A1, A2): ເຊື່ອມຕໍ່ແຮງດັນຄວບຄຸມ 24V AC/DCtage to these terminals. Polarity is generally not critical for AC/DC coils, but always follow specific instructions if provided.
  • ຂົ້ວຕໍ່ໄຟຟ້າ (1, 2, 3, 4): These are the main power contacts. Terminals 1 and 3 are the inputs, and 2 and 4 are the outputs for the two normally open poles. Connect the load circuit to these terminals.

Ensure all wire connections are tight and secure to prevent loose connections, which can lead to overheating or intermittent operation.

Finder 22.32.0.024.4320 Modular Contactor with LED and Mechanical Indicator

Figure 1: Finder 22.32.0.024.4320 Modular Contactor. This image displays the Finder 22.32.0.024.4320 modular contactor, showing its compact design, terminal connections, and the integrated LED and mechanical status indicators. The model number and electrical ratings are visible on the front panel.

5. ຄໍາແນະນໍາການດໍາເນີນງານ

The Finder 22.32.0.024.4320 is an automatically operated modular contactor. Its function is to switch electrical loads on or off based on the energization of its control coil.

  1. ລັດ​ທີ່​ຂາດ​ພະ​ລັງ​ງານ​: ໃນເວລາທີ່ບໍ່ມີ voltage is applied to the coil terminals (A1, A2), the contactor's normally open (NO) power contacts (1-2 and 3-4) remain open. The LED indicator will be off, and the mechanical indicator will show the 'open' position.
  2. ສະຖານະພະລັງງານ: When the rated 24V AC/DC control voltage is applied to the coil terminals (A1, A2), the coil energizes, causing the contacts to close. The LED indicator will illuminate, and the mechanical indicator will show the 'closed' position. This action connects the load circuit.
  3. ການ​ດໍາ​ເນີນ​ງານ​ອັດ​ຕະ​ໂນ​ມັດ​: The contactor will maintain its energized state as long as the control voltage is present. When the control voltage is removed, the coil de-energizes, and the contacts return to their normally open position, disconnecting the load.

Monitor the LED and mechanical indicators to confirm the operational status of the contactor.

6. ບໍາລຸງຮັກສາ

ການບໍາລຸງຮັກສາເປັນປົກກະຕິຈະຊ່ວຍຮັບປະກັນຄວາມທົນທານແລະການດໍາເນີນງານທີ່ຫນ້າເຊື່ອຖືຂອງ contactor.

  • ການກວດກາສາຍຕາ: ກວດ​ເບິ່ງ contactor ເປັນ​ໄລ​ຍະ​ສໍາ​ລັບ​ອາ​ການ​ຂອງ​ຄວາມ​ເສຍ​ຫາຍ​ທາງ​ດ້ານ​ຮ່າງ​ກາຍ​, ການ​ປ່ຽນ​ສີ​, ຫຼື​ການ​ເຊື່ອມ​ຕໍ່​ຂາດ​.
  • ທໍາຄວາມສະອາດ: ຖ້າຈຳເປັນ, ໃຫ້ທຳຄວາມສະອາດດ້ານນອກຂອງຄອນແທັກເຕີຢ່າງລະມັດລະວັງດ້ວຍຜ້າແຫ້ງທີ່ບໍ່ມີຂົນ. ຢ່າໃຊ້ສານລະລາຍ ຫຼື ນ້ຳຢາທຳຄວາມສະອາດທີ່ມີສານຂັດ. ໃຫ້ແນ່ໃຈວ່າໄຟຟ້າໄດ້ຖືກຕັດກ່ອນທຳຄວາມສະອາດ.
  • ຄວາມເຄັ່ງຄັດຢູ່ປາຍຍອດ: Check terminal screws for tightness, especially after initial installation and during routine maintenance. Loose connections can cause overheating.
  • ເງື່ອນໄຂສິ່ງແວດລ້ອມ: ຮັບປະກັນວ່າສະພາບແວດລ້ອມການດຳເນີນງານຍັງຄົງຢູ່ພາຍໃນຂອບເຂດອຸນຫະພູມ ແລະ ຄວາມຊຸ່ມຊື່ນທີ່ກຳນົດໄວ້ເພື່ອປ້ອງກັນການລົ້ມເຫຼວກ່ອນໄວອັນຄວນ.

7. ການແກ້ໄຂບັນຫາ

If the contactor is not functioning as expected, consider the following troubleshooting steps:

  • Contactor Not Engaging:
    • Verify that the correct control voltage (24V AC/DC) is applied to terminals A1 and A2.
    • Check for loose wiring connections at the coil terminals.
    • Ensure the control circuit is complete and there are no open circuits.
    • Inspect the coil for any visible damage.
  • Contacts Not Closing/Opening Properly:
    • If the coil is energized but contacts do not close, there might be a mechanical obstruction or internal fault.
    • If contacts remain closed after coil de-energization, check for contact welding due to overload or short circuit.
  • ຄວາມຮ້ອນເກີນ:
    • Check for loose power connections, which can cause resistance and heat.
    • Ensure the load current does not exceed the 25A rating of the contacts.
    • Verify adequate ventilation around the contactor.

If issues persist after troubleshooting, contact a qualified electrician or Finder technical support.

8. ຂໍ້ມູນຈໍາເພາະ

Dimensional drawing of Finder 22.32.0.024.4320 Modular Contactor

Figure 2: Dimensional Drawing. This technical drawing illustrates the precise dimensions of the Finder 22.32.0.024.4320 modular contactor in millimeters, including height, width, and depth, crucial for installation planning and panel integration.

ພາລາມິເຕີມູນຄ່າ
ໝາຍເລກຕົວແບບ22.32.0.024.4320
Coil Voltage24V AC / DC
ການຕັ້ງຄ່າຕິດຕໍ່DPST-NO
ການຈັດອັນດັບການຕິດຕໍ່25A
ວັດສະດຸຕິດຕໍ່AGSNO2
ຕົວຊີ້ວັດLED & Mechanical
ປະເພດການຕິດຕັ້ງDIN Rail Mount
ຂະໜາດສິນຄ້າ (L x W x H)0.69 x 2.39 x 3.31 ນິ້ວ (ປະມານ 17.5 x 60.8 x 84 ມມ)
ນ້ໍາຫນັກລາຍການ3.88 ອອນສ໌ (ປະມານ 110 ກຣາມ)
ຜູ້ຜະລິດຊອກຫາ
ຮູບແບບການເຮັດວຽກອັດຕະໂນມັດ

9. ການຮັບປະກັນແລະການສະຫນັບສະຫນູນ

For warranty information, please refer to the documentation provided with your purchase or contact your authorized Finder distributor. For technical support or further inquiries, please visit the official Finder webເວັບໄຊ ຫຼືຕິດຕໍ່ພະແນກບໍລິການລູກຄ້າຂອງເຂົາເຈົ້າ.

You can find more information about Finder products at the Finder Store.