The Notifier FRM-1 is an intelligent addressable relay module designed for use in fire alarm systems. This module provides a single Form-C relay contact that can be programmed to operate in response to specific system events. It is an essential component for controlling external devices such as door holders, fans, or other auxiliary equipment within a fire detection and alarm system.
This manual provides detailed instructions for the proper installation, operation, and maintenance of the FRM-1 module to ensure its reliable performance and compliance with safety standards.
ສິນຄ້າເກີນview

ຮູບ 1: ດ້ານຫນ້າ view of the FRM-1 module, showing the Notifier logo and the status indicator LED.

ຮູບ 2: ດ້ານຫລັງ view of the FRM-1 module, displaying the product label with model number, patent details, and terminal assignments for wiring.

ຮູບທີ 3: ພາຍໃນ view of the FRM-1 module, revealing the screw terminals for loop and address connections, and the mounting plate.

Figure 4: The FRM-1 module with its original packaging and a small installation guide.
The FRM-1 module is compact and designed for easy integration into existing fire alarm control panels (FACP) that support Notifier's intelligent addressable protocol. It features an intelligent design for reliable communication and operation within the system.
ຂໍ້ມູນຄວາມປອດໄພ
Always observe the following safety precautions when installing, operating, or maintaining the FRM-1 module:
- Installation must be performed by qualified personnel in accordance with all local and national electrical codes and standards.
- Disconnect all power to the fire alarm control panel before installing or servicing the module.
- ຮັບປະກັນການຕໍ່ຫນ້າດິນທີ່ເຫມາະສົມເພື່ອປ້ອງກັນການຊ໊ອກໄຟຟ້າ.
- Do not operate the module outside its specified voltage ແລະການຈັດອັນດັບໃນປະຈຸບັນ.
- Refer to the fire alarm control panel manual for specific wiring and programming instructions.
ການຕິດຕັ້ງແລະການຕິດຕັ້ງ
The FRM-1 module is designed for DIN rail mounting. Follow these general steps for installation:
- ການຕັດການເຊື່ອມຕໍ່ໄຟຟ້າ: Ensure the fire alarm control panel (FACP) is completely powered down before beginning installation.
- ການຕິດຕັ້ງ: Secure the FRM-1 module to a standard DIN rail within the FACP enclosure or an approved auxiliary enclosure.
- ທີ່ຢູ່: Set the unique address for the module using the rotary switches on the device. Each module on the Signaling Line Circuit (SLC) must have a distinct address.
- ສາຍໄຟ: Connect the SLC wiring to the designated terminals (SLC+ and SLC-) on the module. Refer to Figure 2 for terminal assignments.
- ການເຊື່ອມຕໍ່ Relay: Wire the external device (e.g., door holder, fan control) to the Form-C relay contacts (Normally Open, Normally Closed, Common) as required by your application. Ensure all connections are secure.
- ການຢັ້ງຢືນ: ກວດສອບການເຊື່ອມຕໍ່ສາຍໄຟທັງໝົດຄືນໃໝ່ເພື່ອຄວາມຖືກຕ້ອງ ແລະ ຄວາມປອດໄພ.
- ການຟື້ນຟູພະລັງງານ: Restore power to the FACP and verify the module's status indicator.
- ການຂຽນໂປຣແກມລະບົບ: Program the FACP to recognize the new module and configure its relay operation according to the system's design specifications.
Note: Always consult the specific installation manual for your fire alarm control panel for detailed wiring diagrams and compatibility information.
ຄໍາແນະນໍາການດໍາເນີນງານ
The Notifier FRM-1 operates automatically once properly installed and programmed within the fire alarm system. Its operation is dictated by the programming configured in the main fire alarm control panel (FACP).
- ຕົວຊີ້ບອກສະຖານະ: The module features a green LED indicator. This LED typically flashes during normal communication with the FACP and illuminates steadily when the relay is activated or in an alarm/active state, depending on programming.
- Relay Activation: The Form-C relay will change state (from Normally Open to Closed, or Normally Closed to Open) when the FACP sends a command to activate the module, usually in response to an alarm condition or a programmed event.
- ການເບິ່ງແຍງກວດກາ: The FRM-1 module is supervised by the FACP, meaning the panel continuously monitors its presence and operational status. Any communication loss or fault with the module will be reported by the FACP.
For specific operational scenarios and programming details, refer to the programming manual of your Notifier fire alarm control panel.
ບໍາລຸງຮັກສາ
The Notifier FRM-1 module requires minimal maintenance. Regular system checks, as part of the overall fire alarm system maintenance, are crucial to ensure its continued reliability.
- ການກວດກາສາຍຕາ: Periodically inspect the module for any signs of physical damage, loose connections, or environmental issues (e.g., excessive dust, moisture).
- ການທົດສອບການທໍາງານ: As part of routine fire alarm system testing (e.g., annual or semi-annual), verify the proper operation of the FRM-1 module and the external device it controls. This typically involves initiating a test condition that triggers the relay.
- ທໍາຄວາມສະອາດ: If necessary, gently clean the exterior of the module with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure power is disconnected before cleaning.
All maintenance and testing should be conducted by certified fire alarm technicians in accordance with NFPA 72 and local authority having jurisdiction (AHJ) requirements.
ການແກ້ໄຂບັນຫາ
Most issues related to the FRM-1 module will be indicated by the fire alarm control panel (FACP) as a trouble condition. Common troubleshooting steps include:
- Module Trouble/Fault:
- Verify the module's address is correctly set and unique.
- Check SLC wiring connections for looseness, shorts, or opens.
- Ensure the module is receiving proper power from the SLC.
- Consult the FACP's troubleshooting guide for specific trouble codes related to addressable modules.
- Relay ບໍ່ເປີດໃຊ້ງານ:
- Verify the FACP programming for the module's activation logic.
- Check the wiring to the external device connected to the relay contacts.
- Ensure the external device itself is functional.
- ບັນຫາຕົວຊີ້ວັດ LED:
- If the LED is off, check power and SLC communication.
- If the LED is solid when it should be flashing, it may indicate an active state or a fault, depending on the FACP's programming and the module's status.
For complex issues, contact a qualified fire alarm technician or Notifier technical support.
ຂໍ້ມູນຈໍາເພາະ
| ຄຸນລັກສະນະ | ລາຍລະອຽດ |
|---|---|
| ໝາຍເລກຕົວແບບ | FRM-1 |
| ຍີ່ຫໍ້ | ແຈ້ງເຕືອນ |
| ຂະໜາດສິນຄ້າ | 4.9 x 4.9 x 1.3 ນິ້ວ |
| ນ້ໍາຫນັກລາຍການ | 1.6 ອອນ |
| ປະເພດການຕິດຕັ້ງ | DIN Rail Mount |
| ປະເພດຕົວເຊື່ອມຕໍ່ | Screw Terminals |
| ປະເພດການຕິດຕໍ່ | Form-C (Normally Open/Normally Closed) |
| ວັດສະດຸຕິດຕໍ່ | ເງິນ |
| ຮູບແບບການເຮັດວຽກ | ອັດຕະໂນມັດ |
| ແຫຼ່ງພະລັງງານ | Wired Electric (from SLC) |
| UPC | 783863011252 |
| ວັນທີທີ່ມີໃຫ້ທໍາອິດ | ວັນທີ 5 ທັນວາ 2010 |
ຂໍ້ມູນການຮັບປະກັນ
Specific warranty details for the Notifier FRM-1 module are typically provided with the product packaging or can be obtained directly from Notifier or your authorized distributor. Please retain your proof of purchase for warranty claims.
ສະຫນັບສະຫນູນແລະຕິດຕໍ່
For technical assistance, product support, or service inquiries regarding the Notifier FRM-1 Intelligent Addressable Relay Module, please contact your authorized Notifier distributor or Notifier technical support. Contact information can typically be found on the Notifier official website or in the documentation provided with your fire alarm control panel.
It is recommended that all installation, programming, and servicing be performed by qualified and certified fire alarm professionals.