Johnson Controls T-3300-1

ຄູ່ມືການໃຊ້ງານເຄື່ອງຄວບຄຸມອຸນຫະພູມນິວເມຕິກ Johnson Controls T-3300-1

Model: T-3300-1

1. ບົດແນະນຳ

This manual provides essential information for the installation, setup, operation, and maintenance of the Johnson Controls T-3300-1 Pneumatic Thermostat. This device is designed to maintain space comfort by controlling the temperature of air returning to a terminal air conditioning unit. It supports both Direct Acting (DA) and Reverse Acting (RA) configurations, operating within a temperature range of 60 to 150 degrees Fahrenheit.

ກະລຸນາອ່ານຄູ່ມືນີ້ຢ່າງລະອຽດກ່ອນການຕິດຕັ້ງ ແລະ ການດຳເນີນງານເພື່ອຮັບປະກັນການເຮັດວຽກ ແລະ ຄວາມປອດໄພທີ່ເໝາະສົມ.

2. ຂໍ້ມູນຄວາມປອດໄພ

ຄຳເຕືອນ: Installation and servicing must be performed by qualified personnel only. Failure to follow these instructions could result in personal injury or equipment damage.

3. ອົງປະກອບຂອງຜະລິດຕະພັນ

The Johnson Controls T-3300-1 Pneumatic Thermostat consists of the main control unit, a temperature sensing bulb with capillary tubing, and mounting hardware.

Johnson Controls T-3300-1 Pneumatic Thermostat with sensing bulb and mounting bracket

ຮູບທີ 1: ເກີນview of the Johnson Controls T-3300-1 Pneumatic Thermostat. The image displays the olive-green main control unit with a silver adjustment dial labeled 'COOL' to 'WARM'. Two brass pneumatic connections are visible on the top and left side. A coiled copper capillary tube extends from the unit, terminating in a copper temperature sensing bulb. Below the main unit is a silver mounting bracket and a separate silver lever with a black rubber grommet, likely for calibration or linkage.

4. ການຕິດຕັ້ງ

4.1 ການຕິດຕັ້ງເຄື່ອງຄວບຄຸມອຸນຫະພູມ

  1. Select a suitable mounting location that accurately reflects the space temperature and is free from drafts, direct sunlight, or heat sources.
  2. Secure the mounting bracket to the wall or panel using appropriate fasteners.
  3. Attach the main control unit to the mounting bracket.

4.2 Connecting Pneumatic Lines

  1. Connect the main air supply line (typically 15 PSIG for Direct Acting or 20 PSIG for Reverse Acting) to the designated supply port.
  2. Connect the control line to the appropriate output port, leading to the controlled device (e.g., damper actuator, valve).
  3. Ensure all pneumatic connections are tight to prevent air leaks.

4.3 Positioning the Sensing Bulb

Position the temperature sensing bulb in the return air stream or the area where temperature control is desired. Ensure the bulb is not obstructed and can accurately sense the air temperature.

5. ການ​ຕັ້ງ​ຄ່າ​ແລະ Calibration​

5.1 ການເປີດພະລັງງານເບື້ອງຕົ້ນ

Once installation is complete, restore the pneumatic air supply. The thermostat will begin to respond to temperature changes.

5.2 ການຕັ້ງອຸນຫະພູມທີ່ຕ້ອງການ

Rotate the adjustment dial on the front of the thermostat to set the desired temperature. Turn towards 'COOL' for lower temperatures or 'WARM' for higher temperatures. The specific temperature scale may vary based on calibration.

5.3 Calibration (If Required)

If precise temperature control is critical, or if the thermostat's reading appears inaccurate, professional calibration may be necessary. Refer to the detailed service manual or contact a qualified HVAC technician for calibration procedures. This typically involves adjusting internal mechanisms to match a known reference temperature.

6. ການດໍາເນີນງານ

The T-3300-1 thermostat operates by sensing the air temperature via its capillary tube and bulb. Based on the setpoint and the sensed temperature, it modulates the pneumatic output pressure to control a connected device, thereby maintaining the desired space comfort.

The thermostat continuously adjusts its output to counteract temperature deviations from the setpoint.

7. ບໍາລຸງຮັກສາ

The Johnson Controls T-3300-1 is designed for reliable operation with minimal maintenance. However, periodic checks can ensure optimal performance.

8. ການແກ້ໄຂບັນຫາ

This section addresses common issues you might encounter with your T-3300-1 thermostat.

ບັນຫາສາເຫດທີ່ເປັນໄປໄດ້ການແກ້ໄຂ
ເຄື່ອງຄວບຄຸມອຸນຫະພູມບໍ່ຕອບສະໜອງຕໍ່ການປ່ຽນແປງຂອງອຸນຫະພູມ.No pneumatic air supply; Leaking connections; Damaged sensing bulb/capillary.Verify air supply; Check and tighten connections; Inspect sensing bulb for damage (replace if necessary).
ການຄວບຄຸມອຸນຫະພູມທີ່ບໍ່ຖືກຕ້ອງ.Improper calibration; Sensing bulb improperly located; Drafts or heat sources affecting bulb.Recalibrate by qualified personnel; Relocate sensing bulb; Shield bulb from external influences.
Constant air leak from thermostat.Loose pneumatic fittings; Internal diaphragm or valve issue.Tighten fittings; Contact qualified technician for internal repair or replacement.

For issues not listed here or if troubleshooting steps do not resolve the problem, contact Johnson Controls technical support or a certified HVAC professional.

9. ຂໍ້ມູນຈໍາເພາະ

ຄຸນສົມບັດລາຍລະອຽດ
ໝາຍເລກຕົວແບບT-3300-1
ປະເພດຜະລິດຕະພັນPneumatic Thermostat
ຊ່ວງການດໍາເນີນງານ60 ຫາ 150 ອົງສາຟາເຣນຮາຍ
ການປະຕິບັດDirect Acting (DA) / Reverse Acting (RA)
Direct Acting Supply Pressure15 PSIG
Reverse Acting Supply Pressure20 PSIG
ຂະໜາດ (L x W x H)7.0" x 7.0" x 5.0" (Approximate package dimensions, actual unit may vary slightly)
ນ້ຳໜັກ3 ປອນ (ໂດຍ​ປະ​ມານ​)
ສີສີຂຽວ
ປະເພດການຄວບຄຸມPush Button (Refers to adjustment dial)
ຄຸນນະສົມບັດພິເສດAuto Changeover (Functionality)

10. ການຮັບປະກັນແລະການສະຫນັບສະຫນູນ

For warranty information, technical support, or service inquiries, please refer to the official Johnson Controls website or contact their customer service department. Keep your purchase receipt and model number (T-3300-1) handy when contacting support.