System Sensor 5603 135°F Fixed Temperature Mechanical Heat Detector User Manual

1. ບົດແນະນຳ

This manual provides essential information for the proper installation, operation, and maintenance of the System Sensor 5603 135°F Fixed Temperature, Single-Circuit Mechanical Heat Detector. Please read this manual thoroughly before installation and retain it for future reference. This device is designed to detect abnormally high temperatures, indicating a potential fire condition.

2. ຂໍ້ມູນຄວາມປອດໄພ

3. ຜະລິດຕະພັນເກີນview

The System Sensor 5603 is a reliable fixed temperature heat detector designed for various fire protection applications. It operates on a single circuit, providing a clear alarm signal when the ambient temperature reaches 135°F (57.2°C). Its mechanical design ensures consistent performance without the need for batteries.

System Sensor 5603 Fixed Temperature Heat Detector

Image: System Sensor 5603 Fixed Temperature Heat Detector. This image shows the compact, circular design of the heat detector, typically mounted on a ceiling or wall.

ຄຸນ​ນະ​ສົມ​ບັດ​ທີ່​ສໍາ​ຄັນ​:

4. ການຕິດຕັ້ງແລະການຕິດຕັ້ງ

Proper installation is crucial for the effective operation of the heat detector. Refer to NFPA 72, the National Fire Alarm and Signaling Code, and all local codes for specific installation requirements.

ຂັ້ນ​ຕອນ​ການ​ຕິດ​ຕັ້ງ​:

  1. ການຕັດການເຊື່ອມຕໍ່ໄຟຟ້າ: Ensure all power to the fire alarm control panel and associated circuits is disconnected before beginning installation.
  2. ສະຖານທີ່ຕິດຕັ້ງ: Select a mounting location on a ceiling or wall where the detector can effectively monitor the area. Avoid areas with high air currents or obstructions that could prevent heat from reaching the detector.
  3. ຖານ​ຕິດ​ຕັ້ງ​: Secure the appropriate mounting base (sold separately, if applicable) to the ceiling or wall using suitable fasteners.
  4. ສາຍໄຟ: Connect the detector to the fire alarm control panel circuit according to the wiring diagram provided with the mounting base and the control panel documentation. Ensure all connections are secure and polarity is correct. This is a wired device and requires a continuous power source.
  5. Detector Attachment: Attach the 5603 heat detector to the mounting base by aligning the tabs and twisting clockwise until it locks into place.
  6. ການ​ຟື້ນ​ຟູ​ແລະ​ການ​ທົດ​ສອບ​ພະ​ລັງ​ງານ​: Restore power to the fire alarm control panel. Conduct a system test as per the control panel manufacturer's instructions to ensure the detector communicates properly with the system. Note: The 5603 detector itself is not designed for field testing without activation.

5. ການດໍາເນີນງານ

The System Sensor 5603 heat detector operates by continuously monitoring the ambient temperature. When the temperature at the detector's location reaches or exceeds its fixed activation point of 135°F (57.2°C), the internal mechanical element will trigger. This activation causes the detector to change its electrical state, signaling an alarm condition to the connected fire alarm control panel. The control panel will then initiate its programmed alarm sequence, which may include sounding alarms and notifying emergency services.

It is important to understand that this detector responds to heat, not smoke. For comprehensive fire protection, heat detectors should be used in conjunction with smoke detectors and other fire safety equipment as required by local codes and risk assessments.

6. ບໍາລຸງຮັກສາ

Regular maintenance ensures the continued reliability of your heat detector. While the 5603 is a mechanical device with no user-serviceable parts, periodic inspection and cleaning are recommended.

ຂໍ້ແນະນຳການບຳລຸງຮັກສາ:

7. ການແກ້ໄຂບັນຫາ

The System Sensor 5603 is a robust mechanical device. Most issues related to an alarm system not functioning correctly are typically associated with the wiring or the fire alarm control panel rather than the detector itself.

Common Scenarios and Solutions:

For any persistent issues or if you suspect a malfunction, contact a qualified fire alarm technician or System Sensor technical support.

8. ຂໍ້ມູນຈໍາເພາະ

ພາລາມິເຕີມູນຄ່າ
ໝາຍເລກຕົວແບບ5603
ອຸນຫະພູມການເປີດໃຊ້ງານ135°F (57.2°C) Fixed Temperature
ປະເພດວົງຈອນSingle-Circuit
ປະເພດເຄື່ອງກວດຈັບເຄື່ອງກວດຄວາມຮ້ອນກົນຈັກ
ແຫຼ່ງພະລັງງານCorded Electric (System Powered)
ຄວາມຊຸ່ມຊື່ນປະຕິບັດການເຖິງ 95% ບໍ່ condensing
ຂະ ໜາດ (ຜະລິດຕະພັນ)ປະມານ 5 x 5 x 2.5 ນິ້ວ
ນ້ໍາຫນັກລາຍການApproximately 4-6 ounces (0.25 lbs)
ຜູ້ຜະລິດເຊັນເຊີລະບົບ
UPC / GTIN783863022463

9. ການຮັບປະກັນແລະການສະຫນັບສະຫນູນ

ການຮັບປະກັນຈໍາກັດ:

The System Sensor 5603 heat detector comes with a ຮັບປະກັນ 3 ປີຈໍາກັດ from the date of purchase. This warranty covers defects in materials and workmanship under normal use. It does not cover damage resulting from improper installation, misuse, abuse, or unauthorized modifications. For full warranty terms and conditions, please refer to the official System Sensor warranty statement or contact customer support.

ສະຫນັບສະຫນູນດ້ານວິຊາການ:

For technical assistance, installation questions, or warranty claims, please contact System Sensor customer support. Contact information can typically be found on the manufacturer's official webສະຖານທີ່ຫຼືການຫຸ້ມຫໍ່ຜະລິດຕະພັນ.

Webເວັບໄຊ: www.systemsensor.com

ເອກະສານທີ່ກ່ຽວຂ້ອງ - 5603

ກ່ອນview System Sensor i4 Series COSMO-2W & COSMO-4W Combination CO/Smoke Detector Wiring Diagrams
Detailed wiring diagrams and configuration guide for the System Sensor i4 Series COSMO-2W (2-wire) and COSMO-4W (4-wire) combination Carbon Monoxide and Photoelectric Smoke Detectors. Includes panel connections, module terminals, and DIP switch settings for fire alarm systems.
ກ່ອນview ສະຖານີທົດສອບໄລຍະໄກ RTS151KEY-A: ຄູ່ມືການຕິດຕັ້ງ ແລະ ການບຳລຸງຮັກສາ
ຄຳແນະນຳກ່ຽວກັບການຕິດຕັ້ງ ແລະ ການບຳລຸງຮັກສາທີ່ຄົບຖ້ວນສຳລັບສະຖານີທົດສອບໄລຍະໄກ System Sensor RTS151KEY-A, ລວມທັງລາຍລະອຽດສະເພາະ, ການດຳເນີນງານ, ແຜນວາດສາຍໄຟ ແລະ ຂໍ້ມູນການຮັບປະກັນ.
ກ່ອນview System Sensor RTS151KEY(A) Remote Test Station Installation and Maintenance Instructions
Installation and maintenance instructions for the System Sensor RTS151KEY(A) Remote Test Station. This document provides specifications, operation details, wiring diagrams, and warranty information for the product.
ກ່ອນview System Sensor D2 Duct Smoke Detector: Installation and Maintenance Manual
This manual provides comprehensive installation, maintenance, and operational guidelines for the System Sensor D2 Duct Smoke Detector, designed for early smoke detection in HVAC systems. It details specifications, wiring, testing procedures, and troubleshooting.
ກ່ອນview System Sensor 6424 Projected Beam Smoke Detector Technical Specification
Detailed technical specifications, features, applications, wiring diagrams, and mounting instructions for the System Sensor 6424 Projected Beam Smoke Detector, a 4-wire, 24 VDC infrared detector for large, high-ceiling areas.
ກ່ອນview System Sensor D2 Duct Smoke Detector: Installation and Maintenance Manual
This document provides detailed installation and maintenance instructions for the System Sensor D2 Duct Smoke Detector. It covers product specifications, installation procedures, testing, cleaning, and optional accessories for effective operation in HVAC systems.