waveshare UPS Power Module (C)

Waveshare UPS Power Module (C) for Jetson Orin - Instruction Manual

1. ບົດແນະນຳ

This manual provides detailed instructions for the installation, operation, and maintenance of the Waveshare UPS Power Module (C). This module is designed to provide uninterruptible power to Jetson Orin series boards, ensuring stable operation and data integrity during power fluctuations or outages. It supports three 21700 Li-ion batteries (not included) and features real-time battery monitoring via I2C communication.

2. ເນື້ອໃນແພັກເກດ

ກວດ​ສອບ​ວ່າ​ລາຍ​ການ​ທັງ​ຫມົດ​ທີ່​ລະ​ບຸ​ໄວ້​ຂ້າງ​ລຸ່ມ​ນີ້​ແມ່ນ​ລວມ​ຢູ່​ໃນ​ຊຸດ​ຂອງ​ທ່ານ​:

Image showing the Waveshare UPS Power Module (C) and its included accessories: acrylic protection panel, DC dual-plug cable, and screws pack.

Figure 2.1: Included components of the Waveshare UPS Power Module (C) package.

  • UPS Power Module (C) x1
  • Acrylic protection panel x1
  • DC dual-plug cable x1
  • Screws pack x1

Note: Three 21700 Li-ion batteries (9V-12.6V) are NOT included and must be purchased separately.

3. ຂໍ້ຄວນລະວັງຄວາມປອດໄພ

Please read and adhere to the following safety guidelines to prevent personal injury or damage to the product:

Image displaying the Waveshare UPS Power Module (C) with a prominent 'SAFETY CAUTIONS' box listing warnings regarding battery handling.

Figure 3.1: Important safety cautions for battery handling and module usage.

  • Li-ion and Li-Po batteries are inherently unstable. Improper recharging or usage may lead to fire, personal injury, or property damage.
  • ບໍ່ reverse battery polarities during recharging or discharging.
  • ບໍ່ use inferior chargers or charging panels.
  • ບໍ່ mix old batteries with new ones, or use batteries from different brands.
  • ເມື່ອຊື້asing Lithium batteries, ensure their specifications are compatible with this expansion board. Use batteries from reputable manufacturers that have passed aging tests for stability and safety.
  • Lithium batteries have a limited cycle life. Replace them when they reach their maximum cycle life or after two years, whichever comes first.
  • Handle the module and batteries carefully. Keep them away from flammable and explosive materials. Store away from children to prevent accidents.

4. ຄຸນສົມບັດ

The Waveshare UPS Power Module (C) offers the following key features:

Image detailing the features and specifications of the Waveshare UPS Power Module (C).

ຮູບ 4.1: ເກີນview of module features and specifications.

  • Supports simultaneous charging and power output.
  • ຫມໍ້ໄຟ voltage monitoring via I2C bus communication.
  • Pogo pins connector design, ensuring compatibility with Jetson Orin series boards.
  • Onboard Li battery charging chip with dynamic path management for a stable power supply.
  • Multi-battery protection circuits: over charge/discharge, over current, short circuit.
  • Equalizing charge feature and battery reverse indicators for enhanced safety and stability.
  • Supports three 21700 batteries (not included) for extended battery life.

5. ຂໍ້ມູນຈໍາເພາະ

ພາລາມິເຕີມູນຄ່າ
ຜົນໄດ້ຮັບ Voltageຄືກັນກັບ input voltage when power is present; equals battery voltage (9V-12.6V) when no power input.
ການປ້ອນຂໍ້ມູນ Voltage15V~19V
ລົດເມຄວບຄຸມI2C
ຂະໜາດ100 × 79 ມມ
ຮອງຮັບແບັດເຕີຣີ21700 Li-ion Battery × 3 (in series, NOT included)
ຂະໜາດຂຸມສຳລັບຕິດຕັ້ງ2.5ມມ
ວັດສະດຸພາດສະຕິກ
ສີດຳ
ນ້ໍາຫນັກລາຍການ0.12 ກິ​ໂລກ​ຣາມ
ປະເພດຕົວເຊື່ອມຕໍ່Pogo Pins

6. ການຕິດຕັ້ງແລະການຕິດຕັ້ງ

6.1. ການຕິດຕັ້ງຫມໍ້ໄຟ

Insert three 21700 Li-ion batteries (not included) into the battery holders on the module. Ensure correct polarity by matching the '+' and '-' markings on the batteries with those on the module. Incorrect insertion will trigger the battery reverse indicators.

6.2. Module Mounting

Image showing the Waveshare UPS Power Module (C) mounted on a Jetson Orin Nano and a Jetson Orin NX board, demonstrating product compatibility.

Figure 6.1: UPS Power Module (C) compatibility with Jetson Orin Nano and Jetson Orin NX.

Align the UPS Power Module (C) with the pogo pins on your Jetson Orin Nano or Jetson Orin NX board. Gently press down to ensure the pogo pins make proper contact. Secure the module to the Jetson board using the provided screws and standoffs. The mounting holes are designed for precise alignment.

Close-up image of the Waveshare UPS Power Module (C) highlighting the pogo pins connector and various input/output ports and indicators.

Figure 6.2: Pogo Pins Connector and module interfaces.

6.3. Acrylic Protection Panel

Attach the acrylic protection panel to the module using the remaining screws. This panel provides physical protection for the module's circuitry.

6.4. ການເຊື່ອມຕໍ່ພະລັງງານ

Connect the provided DC dual-plug cable to the module's 15V-19V input port. Connect the other end of the cable to a compatible 15V-19V power adapter (not included).

7. ການດໍາເນີນງານ

7.1. ເປີດ/ປິດ

Use the onboard system power button to turn the module and the connected Jetson board on or off. A short press typically powers on, and a long press initiates a shutdown sequence.

7.2. Charging and Power Output

Image showing the UPS Power Module (C) connected to a Jetson Orin board and a display, illustrating uninterruptible power and real-time monitoring.

Figure 7.1: Uninterruptible power and real-time monitoring in action.

When an external power supply (15V-19V) is connected, the module will charge the installed 21700 batteries. The charge indicator LED will illuminate during this process. The module simultaneously provides power to the Jetson board. If external power is lost, the module automatically switches to battery power, ensuring continuous operation without interruption.

7.3. ຕົວຊີ້ວັດ

  • ຕົວຊີ້ວັດການສາກ: Illuminates when batteries are actively charging.
  • ຕົວຊີ້ວັດການສາກໄຟເຕັມ: Illuminates when batteries are fully charged.
  • ຕົວຊີ້ບອກລະບົບ: Indicates the operational status of the system.
  • Battery Reverse Indicators: Light up red if a battery is inserted with incorrect polarity.

8. Dynamic Path Management

Diagram illustrating the dynamic path management system, showing power input, recharger chip, Li battery, and system power consumption flow.

Figure 8.1: Dynamic Path Management System Diagram.

The module incorporates dynamic path management for efficient power delivery. When an external power supply (15V-19V) is connected, the battery output is disconnected. The system is powered directly by the external supply, and the installed batteries are charged simultaneously with a maximum charging current of approximately 1.33A.

Battery charging automatically stops once fully charged and resumes if the battery voltage drops below 12V. This intelligent charging mechanism prevents damage to the batteries from frequent charging and discharging cycles. If the external power supply becomes unavailable, the system seamlessly switches to battery power, ensuring continuous operation without interruption.

9. ການຕິດຕາມເວລາຈິງ

The UPS Power Module (C) utilizes I2C bus communication to monitor critical battery parameters in real-time, including voltage, current, power, and remaining capacity. This data can be accessed by the connected Jetson Orin board.

In scenarios where the battery voltage drops below a critical threshold, the system can be configured via software on the Jetson board to automatically save any open files and initiate a graceful shutdown. This feature helps prevent data loss during unexpected power outages.

When monitoring current, a negative value indicates that the batteries are discharging (powering the system), while a positive value indicates that the batteries are recharging.

10. Safe and Stable Circuit Design

ລະອຽດ view of the Waveshare UPS Power Module (C) circuit board, highlighting various protection circuits, charging circuit, and monitoring components.

Figure 10.1: Internal circuit design with protection features.

The module is engineered with multiple protection circuits to ensure safe and stable operation. These include:

  • ການປົກປ້ອງຄ່າໃຊ້ຈ່າຍເກີນ: Prevents batteries from being charged beyond their safe voltage ຈໍາກັດ.
  • ການປ້ອງກັນການໄຫຼເກີນ: Prevents batteries from being discharged below their safe voltage limit, prolonging battery life.
  • ການປົກປ້ອງເກີນປະຈຸບັນ: ການປົກປ້ອງຈາກການດຶງປະຈຸບັນຫຼາຍເກີນໄປ.
  • ການປ້ອງກັນວົງຈອນສັ້ນ: ຕັດໄຟອັດຕະໂນມັດໃນກໍລະນີເກີດໄຟຟ້າລັດວົງຈອນ.
  • Equalizing Charge Feature: ດຸ່ນດ່ຽງ voltage across the three series-connected 21700 batteries, which helps extend their overall lifespan and performance.
  • Battery Reverse Indicators: Visual alerts (red LEDs) if a battery is inserted with incorrect polarity, preventing immediate damage.

11. Pin Definition and Outline Dimensions

Image showing the pin definitions for the I2C communication and the outline dimensions of the Waveshare UPS Power Module (C) in millimeters.

Figure 11.1: Pin definitions and physical dimensions of the module.

11.1. Pin ຄໍານິຍາມ

The I2C communication pins are defined as follows:

  • GND: ດິນ
  • 3V3: ການປ້ອນຂໍ້ມູນພະລັງງານ 3.3V
  • SDA: Monitoring chip Serial Data line
  • SCL: Monitoring chip Serial Clock line

11.2. ຂະໜາດຂອງໂຄງຮ່າງ

The physical dimensions of the UPS Power Module (C) are:

  • ຄວາມຍາວ: 100.00 ມມ
  • ກວ້າງ: 79.00 ມມ
  • Mounting Hole Spacing (Horizontal): 86.00 ມມ
  • Mounting Hole Spacing (Vertical): 58.00 ມມ

12. ບໍາລຸງຮັກສາ

12.1. ການດູແລຫມໍ້ໄຟ

Regularly inspect the 21700 batteries for any signs of damage or swelling. Replace batteries that show signs of wear or have reached their end-of-life cycle (typically after two years or a specified number of charge cycles).

12.2. ທໍາຄວາມສະອາດ

Keep the module free from dust and debris. Use a soft, dry cloth to gently clean the surface. Avoid using liquids, solvents, or abrasive cleaners, as these can damage the electronic components.

12.3. ການເກັບຮັກສາ

If the module will not be used for an extended period, remove the 21700 batteries and store them separately in a cool, dry place, away from direct sunlight and extreme temperatures. Store the module in its original packaging or an anti-static bag.

13. ການແກ້ໄຂບັນຫາ

13.1. Module Not Powering On

  • ກວດ​ສອບ​ການ​ຕິດ​ຕັ້ງ​ຫມໍ້​ໄຟ​: Ensure all three 21700 batteries are correctly installed with proper polarity.
  • ຢືນຢັນການສາກແບັດເຕີຣີ: Confirm that the batteries are sufficiently charged.
  • ການສະຫນອງພະລັງງານພາຍນອກ: Ensure the 15V-19V external power supply is connected and functional.
  • Pogo Pin Connection: Check that the module is securely connected to the Jetson board via the pogo pins.

13.2. Batteries Not Charging

  • ການສະຫນອງພະລັງງານພາຍນອກ: Confirm the external power supply is connected and providing 15V-19V.
  • ຕົວຊີ້ວັດການສາກ: Check if the charge indicator LED is illuminated. If not, there might be an issue with the power input or battery connection.
  • ສຸຂະພາບຫມໍ້ໄຟ: Verify the health and proper insertion of the batteries.

13.3. I2C Monitoring Data Incorrect or Unavailable

  • I2C Connection: Ensure the pogo pin connection for I2C communication between the module and Jetson board is secure.
  • ການຕັ້ງຄ່າຊອບແວຣ: Verify that the I2C communication is correctly configured in the Jetson board's operating system or application.

13.4. Battery Reverse Indicator On

  • ການປະຕິບັດທັນທີ: Immediately power off the module and correct the battery polarity. Operating with reversed batteries can cause damage.

14. ການຮັບປະກັນແລະການສະຫນັບສະຫນູນ

14.1. ຂໍ້ມູນການຮັບປະກັນ

This Waveshare UPS Power Module (C) is covered by a 1-year manufacturer's warranty from the date of purchase. This warranty covers defects in materials and workmanship under normal use. It does not cover damage caused by misuse, accidents, unauthorized modifications, or improper installation.

14.2. ສະຫນັບສະຫນູນດ້ານວິຊາການ

For additional resources, detailed documentation, software examples, or technical assistance, please refer to the official Waveshare Wiki resources. The Wiki often contains comprehensive guides and community support. Contact information for direct technical support can typically be found on the official Waveshare webເວັບໄຊ.

ເອກະສານທີ່ກ່ຽວຂ້ອງ - UPS Power Module (C)

ກ່ອນview ຄູ່ມືການອອກແບບຜະລິດຕະພັນ NVIDIA Jetson Orin NX ແລະ Nano Series
ຄູ່ມືການອອກແບບທີ່ສົມບູນແບບນີ້ໃຫ້ຄໍາແນະນໍາແລະແນວທາງທີ່ສໍາຄັນສໍາລັບວິສະວະກອນທີ່ພັດທະນາຜະລິດຕະພັນດ້ວຍ NVIDIA Jetson Orin NX ແລະ Jetson Orin Nano System-on-Module (SOM). ມັນລາຍລະອຽດກ່ຽວກັບຄວາມສາມາດຂອງຮາດແວ, ລາຍລະອຽດຂອງອິນເຕີເຟດ, ແລະການປະຕິບັດທີ່ດີທີ່ສຸດສໍາລັບປະສິດທິພາບທີ່ດີທີ່ສຸດ.
ກ່ອນview ບັນທຶກການປ່ອຍ NVIDIA Jetson Linux 35.4.1 GA
ເອກະສານນີ້ໃຫ້ບັນທຶກການປ່ອຍສໍາລັບ NVIDIA Jetson Linux ຮຸ່ນ 35.4.1 GA, ລາຍລະອຽດກ່ຽວກັບຄຸນສົມບັດໃຫມ່, ບັນຫາທີ່ຮູ້, ແລະບັນຫາຄົງທີ່ສໍາລັບເວທີ Jetson.
ກ່ອນview ONX101 Carrier Board User Manual - OmniWise
This user manual provides detailed information on the OmniWise ONX101 Carrier Board, covering its technical specifications, connector descriptions, installation procedures, and software setup for NVIDIA Jetson Orin platforms.
ກ່ອນview NVIDIA Jetson Orin NX and Nano Series: Product Design Guide
Comprehensive technical guide for engineers designing with NVIDIA Jetson Orin NX and Jetson Orin Nano System-on-Modules (SOMs), covering hardware interfaces, power, routing, and best practices for optimal system performance.
ກ່ອນview ຄູ່ມືຜູ້ໃຊ້ Pickerbot Mini - Roboworks
ຄູ່​ມື​ການ​ນໍາ​ໃຊ້​ທີ່​ສົມ​ບູນ​ແບບ​ສໍາ​ລັບ Pickerbot Mini​, ເປັນ​ຫຸ່ນ​ຍົນ​ເລືອກ​ແລະ​ສະ​ຖານ​ທີ່​ອີງ​ໃສ່ ROS​, ອອກ​ແບບ​ສໍາ​ລັບ​ນັກ​ຄົ້ນ​ຄວ້າ​ຫຸ່ນ​ຍົນ​, ການ​ສຶກ​ສາ​, ນັກ​ສຶກ​ສາ​, ແລະ​ຜູ້​ພັດ​ທະ​ນາ​. ກວມເອົາຂໍ້ມູນຈໍາເພາະຂອງຜະລິດຕະພັນ, ຕົວຄວບຄຸມ ROS, ລະບົບການຮັບຮູ້, ອົງປະກອບຮາດແວ, ການຈັດການພະລັງງານ, ການດໍາເນີນງານທາງໂທລະສັບ, ການຂຽນໂປລແກລມສາຍຕາ MIROS, ROS 2 ການເລີ່ມຕົ້ນໄວ, ແລະຊຸດທີ່ຕິດຕັ້ງໄວ້ກ່ອນ.
ກ່ອນview DC-Jetson Orin-V01 Embedded Development Board - Product Specifications
Detailed product specifications for the Dingchang Dianzi DC-Jetson Orin-V01, an embedded development board featuring NVIDIA Jetson Orin architecture, Hexa-core Cortex-A78AE CPU, Ampere GPU, and extensive I/O for AI and industrial applications.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.