Kactoily 4-in-1 Freshwater Aquarium Monitor User Manual

Model: 4-in-1 | Brand: kactoily

1. ບົດແນະນຳ

This manual provides detailed instructions for the Kactoily 4-in-1 Freshwater Aquarium Monitor. This device is designed to measure four critical water parameters simultaneously: pH, Total Dissolved Solids (TDS), Electrical Conductivity (EC), and Temperature. It features a split design with a separate probe unit and display unit, utilizing 2.4GHz technology for data transmission, allowing for convenient real-time monitoring of your aquarium's water quality.

Kactoily 4-in-1 Freshwater Aquarium Monitor with separate display and probe units.

Figure 1: Kactoily 4-in-1 Freshwater Aquarium Monitor

2. ເນື້ອໃນຊຸດ

ກວດ​ສອບ​ວ່າ​ລາຍ​ການ​ທັງ​ຫມົດ​ທີ່​ລະ​ບຸ​ໄວ້​ຂ້າງ​ລຸ່ມ​ນີ້​ແມ່ນ​ລວມ​ຢູ່​ໃນ​ຊຸດ​ຂອງ​ທ່ານ​:

  • Kactoily Wireless Monitor (Display Unit) x1
  • Probe Unit x1
  • Calibration Powder x6
  • ສາຍສາກໄຟ USB x2
  • ຈອກດູດ x2
  • Acrylic Stand x1
  • Plastic Screw x2
  • ຄູ່ມືຜູ້ໃຊ້ x1
  • Charger Plug (Optional) x2
  • Paste (Optional) x1
Diagram of Kactoily 4-in-1 Aquarium Monitor package contents, including monitor, probe, cables, calibration powder, stand, and suction cups.

ຮູບທີ 2: ອົງປະກອບລວມ

3. ຜະລິດຕະພັນເກີນview ແລະຄຸນສົມບັດ

The Kactoily 4-in-1 Aquarium Monitor offers advanced features for comprehensive water quality assessment:

  • ການວັດແທກ 4 ໃນ 1: Measures pH, TDS, EC, and Temperature simultaneously.
  • ການຕິດຕາມເວລາຈິງ: Provides continuous data display on a clear LCD screen.
  • ການ​ອອກ​ແບບ​ແບ່ງ​ປັນ​: Probe and main unit are separate, connected via 2.4GHz technology for flexible placement and observation.
  • High-Precision Probes: Equipped with platinum probes for enhanced longevity and accurate measurements. Probes are easily replaceable.
  • ກັນນໍ້າ IP67: The probe unit is designed to be waterproof for reliable underwater operation.
  • Multiple Fixation Methods: Includes an acrylic stand and suction cups to suit various aquarium setups.
  • ຈໍສະແດງຜົນທີ່ເປັນມິດກັບຜູ້ໃຊ້: Features a 1.6-inch color LCD screen for high-resolution and clear data visibility.
Kactoily 4-in-1 Monitor display showing real-time pH, temperature, TDS, and EC readings with button functions labeled.

Figure 3: Real-time Data Monitoring Display

Diagram illustrating the high-precision industrial-grade probes within the Kactoily monitor's sensor unit.

Figure 4: High-Precision Probe Design

4. ຄໍາແນະນໍາການຕິດຕັ້ງ

  1. Unpack ອົງປະກອບ: ເອົາສິ່ງຂອງທັງໝົດອອກຈາກການຫຸ້ມຫໍ່ຢ່າງລະມັດລະວັງ ແລະ ກວດສອບກັບລາຍການສິ່ງຂອງພາຍໃນກ່ອງ.
  2. Prepare the Probe: Unscrew the probe protection cap clockwise. The cap contains protection fluid; this can be replenished with pure water if needed.
  3. Attach Suction Cups/Stand: Snap the provided suction cups into the sensor unit or attach the acrylic stand as desired. The device supports various fixation methods to suit different fish tank styles.
  4. ຕໍາ​ແຫນ່ງ Probe ໄດ້​: Place the probe unit into the aquarium water, ensuring it is submerged to the appropriate level (between the 'Min level' and 'Max level' markings on the probe unit).
  5. ເຊື່ອມຕໍ່ພະລັງງານ: Plug the data cable from the probe unit into the display unit, and then connect the display unit to a power source using the USB charging cable and adapter. The display will illuminate and begin showing readings.
Kactoily monitor probe installed in an aquarium using suction cups and an acrylic stand.

Figure 5: Probe Installation with Suction Cups and Acrylic Stand

Dimensions of the Kactoily 4-in-1 Aquarium Monitor display unit and probe unit.

Figure 6: Product Dimensions for Placement Consideration

5. ຄໍາແນະນໍາການດໍາເນີນງານ

5.1. ການຕິດຕາມເວລາຈິງ

Once powered on, the monitor will automatically display real-time readings for pH, TDS, EC, and Temperature on its LCD screen. The display is backlit for clear visibility.

5.2. Manual Calibration and Adjustment

To ensure accurate measurements, periodic calibration is necessary. The monitor allows for manual calibration of pH, EC, and temperature settings.

5.2.1. ການປັບຄ່າ pH

  1. Access the settings menu on the display unit.
  2. Navigate to the 'pH-set' option.
  3. Follow the on-screen prompts to perform 2-point or 3-point calibration using standard pH buffer solutions (e.g., pH 4.01, pH 7.00, pH 9.18).
  4. Adjust the pH value if necessary using the 'pH-Adj' option.
Step-by-step guide for pH calibration of the Kactoily 4-in-1 Aquarium Monitor.

Figure 7: pH Calibration Process

5.2.2. EC Calibration

  1. ເຂົ້າເຖິງເມນູການຕັ້ງຄ່າ.
  2. Navigate to the 'EC-set' option.
  3. Perform calibration using a standard EC solution (e.g., 1413 µS/cm).
  4. Adjust the EC or TDS value if necessary using the 'EC-Adj' or 'TDS-Adj' option.
Step-by-step guide for EC calibration of the Kactoily 4-in-1 Aquarium Monitor.

Figure 8: EC Calibration Process

5.2.3. ການຕັ້ງອຸນຫະພູມ

  1. ເຂົ້າເຖິງເມນູການຕັ້ງຄ່າ.
  2. Navigate to the 'Temp-set' option.
  3. Select your preferred unit (Celsius or Fahrenheit) and set any necessary temperature compensation values.
Screen showing temperature unit selection and compensation value setting on the Kactoily monitor.

Figure 9: Temperature Unit and Compensation Setting

6. ບໍາລຸງຮັກສາ

  • Probe Cleaning: Regularly clean the probe tips to prevent buildup that can affect accuracy. Use distilled water or a mild cleaning solution specifically designed for pH/EC probes.
  • ການເກັບຮັກສາໂພຣບ: When not in use, ensure the probe protection cap is securely in place and contains the appropriate storage solution (or pure water) to keep the probe hydrated.
  • Recalibration: Calibrate the device regularly, especially if readings appear inconsistent or after cleaning the probes, to maintain accuracy.
  • ການສະຫນອງພະລັງງານ: Ensure the device is connected to a stable power source.

7. ການແກ້ໄຂບັນຫາ

  • ການອ່ານທີ່ບໍ່ຖືກຕ້ອງ:
    • Ensure probes are clean and free from debris.
    • Perform a full calibration for pH and EC as described in Section 5.2.
    • Check if the probe protection fluid needs replenishment.
  • pH Value Does Not Change During Calibration:
    • Go to the calibration page and select the 'Reset' option to restore factory settings. This will delete all calibration data, requiring a full recalibration.
    Screen prompting to confirm factory reset for the Kactoily 4-in-1 Aquarium Monitor.

    Figure 10: Factory Reset Option

  • ບໍ່ມີຈໍສະແດງຜົນ/ພະລັງງານ:
    • Verify that the USB charging cable is securely connected to both the display unit and the power adapter, and that the adapter is plugged into a working power outlet.
    • Ensure the data cable connecting the probe unit to the display unit is properly inserted.
  • Connectivity Issues (Probe to Display):
    • Ensure the probe unit and display unit are within the specified operating range (6.5 feet).
    • Check for any obstructions that might interfere with the 2.4GHz signal.

8. ຂໍ້ມູນຈໍາເພາະ

ພາລາມິເຕີຊ່ວງຄວາມລະອຽດຄວາມຖືກຕ້ອງ
pH0-140.01±0.05
ອຸນຫະພູມ0-60°C (32-140°F)0.1°C / 0.5°F± 0.1 ° C / ± 0.1 ° F
ທາດລະລາຍທັງໝົດ (TDS)0-999ppm / 1-200ppt1ppm / 1ppt± 5% FS
Electrical Conductivity (EC)0-999µs/cm / 1-400ms/cm1µs/cm / 1ms/cm± 5% FS
ຄວາມເຄັມ0.01%-25%/±0.1% (0.01%-5%) / ±1% (5.1%-25%)
ກາວິທັດສະເພາະ1-1.222//

Table 1: Measurement Specifications

Table detailing parameters, ranges, resolution, and accuracy for pH, Temperature, TDS, EC, Salinity, and Specific Gravity.

Figure 11: Detailed Specifications Chart

ຂໍ້ມູນຈໍາເພາະທົ່ວໄປ:

  • ຍີ່ຫໍ້: kactoily
  • ໝາຍເລກຕົວແບບ: 4-in-1
  • ຂະໜາດແພັກເກດ: 11.81 x 3.74 x 2.44 ນິ້ວ
  • ນ້ໍາຫນັກລາຍການ: 1.65 ປອນ
  • ປະເພດການຕິດຕັ້ງ: Wall Mount (with included accessories)
  • ແບັດເຕີຣີ: No batteries required (powered via USB)

9. ການຮັບປະກັນແລະການສະຫນັບສະຫນູນລູກຄ້າ

Kactoily is committed to the quality of this digital pH meter and provides a warranty or refund for the product. If you encounter any questions or issues regarding your purchase or the operation of the device, please do not hesitate to contact our customer service team. We aim to resolve your problem within 24 hours.

For support, please refer to the contact information provided with your purchase documentation or visit the official kactoily webເວັບໄຊ.