Inkbird ITC-308S

Inkbird ITC308S Temperature Controller User Manual

Model: ITC-308S

1. ບົດແນະນຳ

The Inkbird ITC308S is a reliable and easy-to-use temperature controller designed for precise temperature management in various applications, particularly aquariums. It features dual relay outputs for both heating and cooling devices, ensuring stable temperature control. The unit includes a fully submersible probe for accurate temperature readings in liquid environments.

2. ຂໍ້ມູນຄວາມປອດໄພ

  • Ensure the power supply matches the controller's requirements (110V for this model).
  • Do not immerse the main controller unit in water. Only the probe is submersible.
  • ສະເຫມີຕັດການເຊື່ອມຕໍ່ໄຟຟ້າກ່ອນທີ່ຈະດໍາເນີນການບໍາລຸງຮັກສາຫຼືການຕິດຕັ້ງໃດໆ.
  • ຮັກສາອຸປະກອນໃຫ້ຫ່າງຈາກເດັກນ້ອຍ ແລະສັດລ້ຽງ.
  • ຢ່າໃຊ້ອຸປະກອນຖ້າພາກສ່ວນໃດເສຍຫາຍ.

3. ເນື້ອໃນຊຸດ

  • ITC308S Temperature Controller Unit
  • Submersible Temperature Probe
  • Suction Cup for Probe Mounting
  • ຄູ່ມືຜູ້ໃຊ້
Inkbird ITC308S package contents including controller, probe, and manual.

ຮູບທີ 3.1: The Inkbird ITC308S Temperature Controller and its included accessories, packaged in a brown box.

4. ຜະລິດຕະພັນເກີນview

The ITC308S features a main control unit with a dual LED display, showing both the present value (PV) and set value (SV) temperatures. It has dedicated outlets for heating and cooling devices, and a detachable submersible probe for accurate temperature sensing.

Inkbird ITC308S Temperature Controller with probe and power outlets.

ຮູບທີ 4.1: ເກີນview of the Inkbird ITC308S controller, showing the display, control buttons, power cord, and probe connection.

Close-up of the Inkbird ITC308S power strip with labeled heating and cooling outlets.

ຮູບທີ 4.2: The dual power outlets, clearly marked for 'HEATING' and 'COOLING' devices.

Close-up of the submersible temperature probe with a suction cup for mounting.

ຮູບທີ 4.3: The submersible temperature probe, designed for accurate readings in water, shown with its suction cup.

5. ຂໍ້ມູນຈໍາເພາະ

ຄຸນສົມບັດລາຍລະອຽດ
ຕົວແບບITC-308S
ສະບັບtage120 ໂວນ (AC)
ໂຫຼດຜົນຜະລິດສູງສຸດ1200W (110V)
ໂໝດຄວບຄຸມອຸນຫະພູມOn/Off Control (Heating and Cooling)
ປະເພດ ProbeFully Submersible Aquarium Probe
ປະເພດການສະແດງLED Dual Display
ວັດສະດຸພາດສະຕິກ
ສີGreen, Gray and White

6. ຄໍາແນະນໍາການຕິດຕັ້ງ

  1. ເຊື່ອມຕໍ່ Probe: Plug the submersible temperature probe into the designated port on the main controller unit. Use the provided suction cup to secure the probe inside your aquarium or water bath, ensuring it is fully submerged and away from direct heat sources or strong currents.
  2. ເຊື່ອມຕໍ່ອຸປະກອນເຮັດຄວາມຮ້ອນ/ເຮັດຄວາມເຢັນ: Plug your heating device (e.g., aquarium heater) into the 'HEATING' outlet and your cooling device (e.g., cooling fan) into the 'COOLING' outlet on the power strip. Ensure devices are rated within the controller's maximum output load (1200W).
  3. ເປີດ: Plug the main power cord of the ITC308S controller into a standard 110V AC power outlet. The LED display will illuminate, showing the current temperature (PV) and the set temperature (SV).
Inkbird ITC308S submersible probe installed in an aquarium.

ຮູບທີ 6.1: The submersible probe correctly placed within an aquarium, ensuring accurate temperature measurement.

7. ຄໍາແນະນໍາການດໍາເນີນງານ

  1. View Current Temperature (PV): The upper LED display shows the current measured temperature (Process Value).
  2. View Set Temperature (SV): The lower LED display shows the desired set temperature (Set Value).
  3. ຕັ້ງຄ່າອຸນຫະພູມ:
    • ກົດ SET button once. The SV display will flash.
    • ໃຊ້ ຂຶ້ນ (▲) or ລົງ (▼) ປຸ່ມເພື່ອປັບອຸນຫະພູມທີ່ຕ້ອງການ.
    • ກົດ SET ອີກເທື່ອໜຶ່ງເພື່ອຢືນຢັນ ແລະບັນທຶກການຕັ້ງຄ່າ, ຫຼືລໍຖ້າສອງສາມວິນາທີເພື່ອໃຫ້ມັນບັນທຶກອັດຕະໂນມັດ.
  4. Heating/Cooling Indication: The 'HEATING' or 'COOLING' indicator lights will illuminate when the respective outlet is active.
  5. ການປັບອຸນຫະພູມ: Refer to the detailed instructions in the included paper manual for advanced settings like temperature calibration, differential settings, and alarm parameters. These settings allow fine-tuning of the controller's response.
  6. ການແຈ້ງເຕືອນ: The controller features over-temperature and sensor fault alarms. If an alarm triggers, the display will show an error code (e.g., 'HHH' for over-temperature, 'LLL' for under-temperature, 'ERR' for sensor fault) and an audible alert may sound. Address the issue promptly.

8. ບໍາລຸງຮັກສາ

  • ທໍາ​ຄວາມ​ສະ​ອາດ Probe​: Regularly inspect and clean the submersible probe to prevent algae or mineral buildup, which can affect accuracy. Use a soft cloth and mild cleaning solution if necessary.
  • ໜ່ວຍຄວບຄຸມ: Wipe the main controller unit with a dry, soft cloth. Do not use abrasive cleaners or immerse it in water.
  • ການກວດສອບສາຍ: Periodically check all cables for any signs of wear, cuts, or damage. Replace if necessary.

9. ການແກ້ໄຂບັນຫາ

ບັນຫາສາເຫດທີ່ເປັນໄປໄດ້ການແກ້ໄຂ
ຈໍສະແດງຜົນແມ່ນຫວ່າງເປົ່າບໍ່ມີການສະຫນອງພະລັງງານກວດເບິ່ງການເຊື່ອມຕໍ່ໄຟຟ້າແລະປ່ຽງ.
ການອ່ານອຸນຫະພູມບໍ່ຖືກຕ້ອງProbe dirty or improperly placed; calibration neededClean probe, ensure proper submersion, perform temperature calibration.
ອຸປະກອນເຮັດຄວາມຮ້ອນ/ເຮັດຄວາມເຢັນບໍ່ເປີດDevice not plugged in correctly; controller settings incorrect; device malfunctionVerify device connection to correct outlet, check set temperature and differential, test device independently.
ສຽງເຕືອນດັງເລື້ອຍໆTemperature outside set range; alarm limits too narrowAdjust set temperature or alarm high/low limits. Ensure heating/cooling devices are functioning.
'ERR' displayedເຊັນເຊີຜິດພາດCheck probe connection. If error persists, the probe may need replacement.

10. ການຮັບປະກັນແລະການສະຫນັບສະຫນູນ

Inkbird products are designed for reliability and performance. For warranty information, technical support, or service inquiries, please refer to the contact details provided in your product packaging or visit the official Inkbird webເວັບໄຊ. ຮັກສາໃບຮັບເງິນການຊື້ຂອງທ່ານສໍາລັບການຮ້ອງຂໍການຮັບປະກັນ.

Ask a question about this manual