The PC101 Water Quality Tester is designed for quick and accurate measurement of pH and Chlorine (CL2) levels in swimming pools, aquariums, and spas. This device provides instant readings, eliminating the need for complex color matching charts. It is an essential tool for maintaining optimal water quality.

Image: The PC101 Water Quality Tester, showing the main handheld unit, the separate probe with two electrodes, and the coiled cable connecting them.
ຕັ້ງຄ່າ
- ການຕິດຕັ້ງຫມໍ້ໄຟ: The PC101 requires one (1) AA 1.5V Alkaline battery (not included). Open the battery compartment, insert the battery with correct polarity, and close the compartment securely.
- ການເຊື່ອມຕໍ່ Probe: Ensure the probe is securely connected to the main unit.
- Initial Adjustment (Chlorine): Before testing chlorine levels, the meter must be adjusted to the "adjustment point." Refer to the operating instructions for detailed steps on this calibration.
ຄໍາແນະນໍາການດໍາເນີນງານ
General Usage Notes:
- Do not immerse the probe in any liquid other than pool or spa water.
- Always ensure the probe is clean before and after use.
Testing Chlorine (CL2) Level:
- ການກະກຽມ: Ensure the unit is powered on and the probe is clean.
- ການປັບ: Before each chlorine test, adjust the meter to the "adjustment point" as indicated on the device. This typically involves placing the probe in a known solution or following a specific procedure outlined on the device itself (often a dial or switch).
- ການແຊ່ນ້ໍາ: Carefully immerse the probe into the water you wish to test (pool, spa, aquarium).
- ການອ່ານ: Wait for the reading to stabilize on the large screen. The safe measure range for Chlorine Level is 1.2 to 1.7 ppm.
Testing pH Level:
- ການກະກຽມ: Ensure the unit is powered on and the probe is clean.
- ການແຊ່ນ້ໍາ: Carefully immerse the probe into the water you wish to test.
- ການອ່ານ: Wait for the reading to stabilize on the large screen. The safe measure range for pH Level is 7.2 to 7.8.

ຮູບພາບ: A close-up view of the PC101 tester's display, showing the analog scales for pH and Chlorine levels with color-coded indicators for ideal ranges.
ບໍາລຸງຮັກສາ
- ທໍາຄວາມສະອາດ Probe: After each use, gently rinse the probe with clean water and wipe it dry with a soft cloth. Do not use abrasive materials or harsh chemicals.
- ການເກັບຮັກສາ: Store the PC101 tester in a dry, cool place, away from direct sunlight and extreme temperatures. Ensure the probe is protected from damage.
- ການປ່ຽນແບັດເຕີຣີ: If the display becomes dim or readings are inconsistent, replace the AA 1.5V battery.
ການແກ້ໄຂບັນຫາ
| ບັນຫາ | ສາເຫດທີ່ເປັນໄປໄດ້ | ການແກ້ໄຂ |
|---|---|---|
| ບໍ່ມີຈໍສະແດງຜົນ ຫຼື ມືດ | ແບັດເຕີຣີຕໍ່າ ຫຼືຕາຍ | Replace the 1.5V AA battery. |
| Inaccurate Chlorine readings | Meter not adjusted to "adjustment point" before testing | Ensure the meter is adjusted correctly before each chlorine test. |
| ການອ່ານທີ່ບໍ່ສອດຄ່ອງ | Dirty probe electrodes; Battery low | Clean the probe electrodes thoroughly; Replace battery. |
| ສືບສວນຄວາມເສຍຫາຍ | Physical damage or immersion in non-pool/spa liquids | Avoid immersing the probe in liquids other than pool/spa water. Handle with care. Replacement probe may be required. |
ຂໍ້ມູນຈໍາເພາະ
- ຕົວແບບ: PC101
- Chlorine Level Safety Range: 1.2 ຫາ 1.7 ppm
- pH Level Safety Range: 7.2 ຫາ 7.8
- ການສະຫນອງພະລັງງານ: 1 x AA 1.5V Alkaline Battery (not included)
- ຂະໜາດຫົວໜ່ວຍຫຼັກ: ປະມານ 190 x 120 ມມ
- Probe with Handle Length: 150 ມມ
- Probe (electrode part only) Length: 48 mm (excluding black band)
- ຄວາມຍາວສາຍ: 130 ມມ
- ຄຸນສົມບັດການສະແດງ: ໄຮ້ສາຍ
ການຮັບປະກັນແລະການສະຫນັບສະຫນູນ
No specific warranty or support information is provided with this product. For any issues, please refer to the troubleshooting section or contact your retailer.
Ask a question about this manual