Planet GS-4210-16P4C

Planet GS-4210-16P4C Managed PoE+ Gigabit Switch User Manual

Model: GS-4210-16P4C

1. ບົດແນະນຳ

The Planet GS-4210-16P4C is a high-performance Managed PoE+ Gigabit Switch designed for robust network applications. This device features IPv6/IPv4 dual stack management and a built-in L2/L4 Gigabit switching engine. It includes 16 10/100/1000BASE-T ports with 30-watt 802.3at Power over Ethernet Plus (PoE+) capabilities, alongside 4 additional Gigabit TP/SFP combo ports. With a total power budget of up to 220 watts, the GS-4210-16P4C offers a reliable and efficient Power over Ethernet solution for various network environments.

2. ຜະລິດຕະພັນເກີນview

The GS-4210-16P4C switch integrates advanced features to enhance network reliability and management. Its intelligent PoE functions are designed to optimize the availability of connected Powered Devices (PDs).

ຄຸນ​ນະ​ສົມ​ບັດ​ທີ່​ສໍາ​ຄັນ​:

  • 16 10/100/1000T 802.3at PoE+ Ports
  • 4 100/1000X SFP Ports
  • Total Power Budget: 220 Watts @ 25°C, 190W @ 50°C
  • Switch Throughput: 29.76Mpps
  • ອຸນ​ຫະ​ພູມ​ປະ​ຕິ​ບັດ​ການ​: 0° ເຖິງ 50°C​
  • IPv6/IPv4 Dual Stack Management
  • Intelligent PoE Functions (PD Alive Check, PoE Schedule)

ແຜນຜັງດ້ານຫນ້າ:

The front panel of the GS-4210-16P4C switch provides access to all network ports and status indicators.

ດ້ານໜ້າ view of the Planet GS-4210-16P4C Managed PoE+ Gigabit Switch
ຮູບ 2.1: ດ້ານຫນ້າ view of the Planet GS-4210-16P4C switch, showing 16 PoE+ Gigabit Ethernet ports and 4 Gigabit TP/SFP combo ports.

This image displays the front of the Planet GS-4210-16P4C switch. On the left, there is a console port and LED indicators for power, system status, and PoE activity. The central section features two blocks of eight 10/100/1000BASE-T PoE+ ports, totaling 16 ports. To the right, there are four Gigabit TP/SFP combo ports, offering flexible connectivity options.

ການຈັດວາງແຜງດ້ານຫຼັງ:

The rear panel includes power input and cooling components.

ຫລັງ view of the Planet GS-4210-16P4C Managed PoE+ Gigabit Switch
ຮູບ 2.2: ດ້ານຫລັງ view of the Planet GS-4210-16P4C switch, showing cooling fans and power input.

This image shows the rear of the Planet GS-4210-16P4C switch. It features two cooling fans for thermal management, ensuring stable operation. On the far right, there is the AC power input socket and a power switch.

3. ຕັ້ງຄ່າ

Follow these steps to set up your Planet GS-4210-16P4C switch:

  1. ການຫຸ້ມຫໍ່: Carefully remove the switch from its packaging. Verify that all components are present, including the switch unit, power cord, and any included mounting hardware.
  2. ການຕິດຕັ້ງ: The switch can be placed on a desktop or mounted in a standard 19-inch rack. Ensure adequate ventilation around the device to prevent overheating.
  3. ການເຊື່ອມຕໍ່ພະລັງງານ: Connect the provided AC power cord to the power input socket on the rear panel of the switch and then to a suitable power outlet. Ensure the power switch is in the OFF position before connecting.
  4. ການເຊື່ອມຕໍ່ເຄືອຂ່າຍ:
    • PoE+ Devices: Connect your Power over Ethernet (PoE) compatible devices (e.g., IP cameras, wireless access points) to the 16 10/100/1000BASE-T PoE+ ports using standard Ethernet cables.
    • Uplink/Non-PoE Devices: Use the 4 Gigabit TP/SFP combo ports for uplink connections to other network devices or for connecting non-PoE Gigabit devices. SFP transceivers can be inserted into the SFP slots for fiber optic connections.
  5. ເປີດ: Flip the power switch on the rear panel to the ON position. Observe the LED indicators on the front panel to confirm proper power-up and system initialization.
  6. ການຕັ້ງຄ່າເບື້ອງຕົ້ນ: ເຂົ້າເຖິງສະວິດ web management interface via a connected computer. Refer to the separate software user manual for detailed instructions on initial IP address configuration and login procedures. The switch supports both IPv6 and IPv4 management.

4. ຄໍາແນະນໍາການດໍາເນີນງານ

The GS-4210-16P4C switch offers intelligent PoE functions to enhance network management and efficiency.

4.1 Intelligent PoE Functions

  • PD Alive Check: The switch can be configured to monitor the status of connected Powered Devices (PDs) in real-time using ping actions. If a PD stops responding, the GS-4210-16P4C will automatically cycle the power on the corresponding PoE port, effectively rebooting the PD. This feature significantly improves network reliability by automatically restoring non-responsive devices and reduces the need for manual intervention.
  • ຕາຕະລາງ PoE: This function allows administrators to enable or disable PoE power feeding for each PoE port during specified time intervals. This is a powerful tool for energy saving, as it can power off devices during non-business hours. It also enhances security by ensuring that certain devices are only operational when needed. Additionally, the PoE schedule can be used to automatically reboot connected PoE IP cameras or wireless access points at a specific time each week, preventing potential crashes due to buffer overflow.

4.2 Web ການໂຕ້ຕອບການຄຸ້ມຄອງ

ສະຫຼັບຂອງ web management interface provides comprehensive control and monitoring capabilities. Through this interface, you can:

  • Configure network settings (IP addresses, VLANs, QoS).
  • Manage PoE settings, including the PD Alive Check and PoE Schedule functions.
  • Monitor the status of all ports and connected devices.
  • View a power usage chart to track the real-time power consumption of connected PDs.

5. ບໍາລຸງຮັກສາ

Regular maintenance ensures the optimal performance and longevity of your GS-4210-16P4C switch.

  • ການອັບເດດເຟີມແວ: ກວດສອບຜູ້ຜະລິດເປັນໄລຍະ website for firmware updates. Applying the latest firmware can improve performance, add new features, and address security vulnerabilities.
  • ເງື່ອນໄຂສິ່ງແວດລ້ອມ: Ensure the switch operates within its specified temperature range (0° to 50°C) and humidity levels. Keep the area around the switch clear to allow for proper airflow and cooling.
  • ທໍາຄວາມສະອາດ: Gently clean the exterior of the switch with a soft, dry cloth. Do not use liquid or aerosol cleaners. Ensure ventilation openings are free from dust accumulation.
  • PoE Device Reboot Schedule: Utilize the PoE schedule function to periodically reboot connected IP cameras or access points. This proactive measure can prevent device crashes and maintain consistent performance.

6. ການແກ້ໄຂບັນຫາ

If you encounter issues with your GS-4210-16P4C switch, consider the following troubleshooting steps:

  • ບໍ່ມີພະລັງງານ: Verify that the power cord is securely connected to both the switch and the power outlet. Check the power switch position and ensure the power outlet is functional.
  • ບໍ່ມີການເຊື່ອມຕໍ່ເຄືອຂ່າຍ:
    • Check the Ethernet cables for secure connections and damage.
    • Verify the link/activity LEDs on the switch ports and connected devices.
    • Ensure IP address settings are correct for managed access.
  • ອຸປະກອນ PoE ບໍ່ເປີດ:
    • Confirm the connected device is PoE compatible and meets 802.3at standards.
    • ກວດເບິ່ງ LED ສະຖານະ PoE ສໍາລັບພອດສະເພາະ.
    • Verify the total power budget is not exceeded. The switch has a 220W budget.
    • Utilize the PD Alive Check feature to automatically restart non-responsive devices.
    • Check the PoE schedule settings to ensure the port is enabled during operational hours.
  • ປະສິດທິພາບເຄືອຂ່າຍຊ້າ:
    • ກວດສອບການຈະລາຈອນເຄືອຂ່າຍ ຫຼື ການວົນຊ້ຳຫຼາຍເກີນໄປ.
    • Ensure cables are of appropriate quality and length.
    • Review switch configuration for any bandwidth limitations or QoS settings.
  • ການເຂົ້າເຖິງ Web ການໂຕ້ຕອບ: Ensure your computer's IP address is in the same subnet as the switch's management IP. Clear browser cache or try a different browser if issues persist.

7. ຂໍ້ມູນຈໍາເພາະ

Detailed technical specifications for the Planet GS-4210-16P4C Managed PoE+ Gigabit Switch:

ຄຸນສົມບັດຂໍ້ມູນຈໍາເພາະ
ໝາຍເລກຕົວແບບGS-4210-16P4C
ທ່າເຮືອ16 x 10/100/1000BASE-T 802.3at PoE+
4 x 100/1000X SFP (Combo)
ມາດຕະຖານ PoEIEEE 802.3at/af
ງົບປະມານພະລັງງານທັງໝົດ220 Watts @ 25°C
190 Watts @ 50°C
ການບໍລິໂພກພະລັງງານ251 Watts / 861.2 BTU (Max)
ສະຫຼັບການສົ່ງຜ່ານ29.76 Mpps
ຄວາມອາດສາມາດສະຫຼັບ40 Gbps
ອຸນຫະພູມປະຕິບັດການ0° ເຖິງ 50°C (32° ຫາ 122°F)
ຂະໜາດສິນຄ້າ (L x W x H)17.32 x 11.81 x 1.75 ນິ້ວ (440 x 300 x 44.5 ມມ)
ນ້ໍາຫນັກລາຍການ9.09 ປອນ (4.12 ກິ​ໂລ​)
ຜູ້ຜະລິດເຕັກໂນໂລຊີດາວເຄາະ
ການຄຸ້ມຄອງIPv6/IPv4 Dual Stack, Web, SNMP, Telnet

8. ຂໍ້ມູນຄວາມປອດໄພ

ກະລຸນາປະຕິບັດຕາມຄຳແນະນຳດ້ານຄວາມປອດໄພຕໍ່ໄປນີ້ເພື່ອປ້ອງກັນຄວາມເສຍຫາຍຕໍ່ອຸປະກອນ ຫຼື ການບາດເຈັບຕໍ່ຕົວທ່ານເອງ:

  • ຢ່າເປີດອຸປະກອນ casing. ອ້າງອີງການບໍລິການທັງໝົດໃຫ້ກັບບຸກຄະລາກອນທີ່ມີຄຸນວຸດທິ.
  • ຮັບປະກັນການສະຫນອງພະລັງງານ voltage ກົງກັບຂໍ້ກຳນົດທີ່ລະບຸໄວ້ໃນປ້າຍອຸປະກອນ.
  • Avoid placing the device in areas with high humidity, extreme temperatures, or direct sunlight.
  • ຫ້າມກີດຂວາງການເປີດລະບາຍອາກາດ.
  • Disconnect power before cleaning or moving the device.

9. ການຮັບປະກັນແລະການສະຫນັບສະຫນູນ

For warranty information and technical support, please refer to the documentation provided with your purchase or visit the official Planet Technology website. Contact their customer service for assistance with product registration, troubleshooting, or service requests.

ເອກະສານທີ່ກ່ຽວຂ້ອງ - GS-4210-16P4C

ກ່ອນview PLANET GS-4210 Series Quick Installation Guide for L2/L4 Managed Gigabit Ethernet Switches
This Quick Installation Guide provides essential steps for setting up and configuring PLANET's GS-4210 Series L2/L4 Managed Gigabit Ethernet Switches with 802.3bt PoE++ technology. Learn about package contents, requirements, terminal setup, IP configuration, and web ການຄຸ້ມຄອງ.
ກ່ອນview PLANET GS-4210 Series Managed Gigabit Ethernet Switches: ຄູ່ມືການຕິດຕັ້ງດ່ວນ
ເອກະສານນີ້ໃຫ້ຄໍາແນະນໍາການຕິດຕັ້ງໄວສໍາລັບ PLANET GS-4210 Series ຂອງ Managed Gigabit Ethernet Switches. ມັນກວມເອົາເນື້ອໃນຊຸດ, ຄວາມຕ້ອງການລະບົບ, terminal ແລະ web ການ​ຈັດ​ຕັ້ງ​ການ​ຄຸ້ມ​ຄອງ​, ການ​ປະ​ຢັດ​ການ​ຕັ້ງ​ຄ່າ​, ແລະ​ການ​ແກ້​ໄຂ​ບັນ​ຫາ​.
ກ່ອນview ຄູ່ມືການຕິດຕັ້ງດ່ວນຂອງສະວິດທີ່ມີການຈັດການ PLANET GS-4210
ຄູ່ມືການຕິດຕັ້ງດ່ວນສຳລັບສະວິດ Gigabit Ethernet ທີ່ມີການຈັດການຊຸດ PLANET GS-4210, ເຊິ່ງກວມເອົາເນື້ອໃນຊຸດ, ຂໍ້ກຳນົດ, ການຕັ້ງຄ່າເຄື່ອງຮັບສັນຍານ, web ການຄຸ້ມຄອງ, ແລະ ການກູ້ຄືນການຕັ້ງຄ່າເລີ່ມຕົ້ນ.
ກ່ອນview PLANET GS-4210 Series Managed Switch User Manual
Comprehensive user manual for the PLANET GS-4210-16T2S, GS-4210-24T2S, and GS-4210-24P2S managed switches. This guide covers installation, configuration, management, and troubleshooting for these high-performance network switches.
ກ່ອນview PLANET AVS-4210-8HP2X Pro AV Managed Gigabit PoE Switch Quick Installation Guide
Quick installation guide for the PLANET AVS-4210-8HP2X Pro AV Managed Gigabit PoE Switch, covering setup, web management, console access, and support.
ກ່ອນview PLANET AVS-4210-24HP4X Pro AV Managed Gigabit PoE Switch Quick Installation Guide
This guide provides essential steps for installing and configuring the PLANET AVS-4210-24HP4X Pro AV Managed Gigabit PoE Switch. It covers package contents, system requirements, web management login, console setup, IP address configuration, saving settings, and default recovery procedures.