APC AP7922

APC AP7922 32A 230V Switched Rack PDU User Manual

Model: AP7922 | Brand: APC by Schneider Electric

ແນະນຳ

This manual provides essential instructions for the safe installation, operation, and maintenance of your APC AP7922 32A 230V Switched Rack PDU. The AP7922 is a rack-mountable power distribution unit designed to provide advanced power control and monitoring capabilities for IT equipment in data centers and server rooms. It features AC 230V input, Ethernet 10/100 connectivity, and 16 output connectors, all within a 2U, 19-inch form factor.

ຂໍ້ມູນຄວາມປອດໄພທີ່ສໍາຄັນ

Please read and understand all safety instructions before installing or operating this equipment. Failure to follow these instructions could result in electric shock, fire, or serious injury.

  • ອຸປະກອນນີ້ມີຈຸດປະສົງເພື່ອໃຊ້ພາຍໃນເຮືອນເທົ່ານັ້ນ.
  • Connect the PDU to a properly grounded power source.
  • Do not attempt to open or service the PDU. Refer all servicing to qualified personnel.
  • Ensure the total current draw of connected equipment does not exceed the PDU's maximum current rating (32 Amps).
  • ຕັດການເຊື່ອມຕໍ່ໄຟຟ້າກ່ອນທີ່ຈະດໍາເນີນການບໍາລຸງຮັກສາຫຼືການຕິດຕັ້ງຂັ້ນຕອນ.

ເນື້ອໃນຊຸດ

ກວດ​ສອບ​ວ່າ​ລາຍ​ການ​ທັງ​ຫມົດ​ແມ່ນ​ມີ​ຢູ່​ໃນ​ການ​ຍົກ​ເລີກ​ການ​ຫຸ້ມ​ຫໍ່​:

  • APC AP7922 Switched Rack PDU
  • ຄູ່ມືການຕິດຕັ້ງ
  • ວົງເລັບ rack-mounting
  • Serial configuration cable
  • CD ເອກະສານ

ຄຸນສົມບັດຜະລິດຕະພັນ

The APC AP7922 Switched Rack PDU offers the following key features:

  • ສະຫຼັບປລັກສຽບ: Remotely control power to individual outlets for power cycling, delayed sequencing, and load shedding.
  • ການຄຸ້ມຄອງເຄືອຂ່າຍ: Full-featured network management interface via Ethernet 10/100 for remote monitoring and control.
  • ການຕິດຕາມປັດຈຸບັນ: Monitor the aggregate current draw per PDU to prevent circuit overloads.
  • ການອອກແບບ Rack-Mountable: Occupies 2U of rack space, compatible with standard 19-inch racks.
  • Output Connectors: Equipped with 16 C13 output connectors.
  • ການປ້ອນຂໍ້ມູນ Voltage: Supports AC 230V input.
APC AP7922 Switched Rack PDU front view with outlets and network port

ຮູບພາບ: ທາງຫນ້າ view of the APC AP7922 Switched Rack PDU, showing the 16 C13 outlets and network interface.

ຄໍາແນະນໍາການຕິດຕັ້ງ

1. ການຕິດຕັ້ງ Rack

  1. Identify two available 2U spaces in your standard 19-inch equipment rack.
  2. Attach the provided rack-mounting brackets to the PDU using the screws supplied.
  3. Secure the PDU into the rack using appropriate rack screws. Ensure it is firmly seated and level.

2. ການເຊື່ອມຕໍ່ພະລັງງານ

  1. Connect the PDU's input power cord to a dedicated 230V, 32A power source. Ensure the power source is properly grounded.
  2. Do not overload the circuit. Verify that the total load of connected devices will not exceed 32 Amps.

3. ການເຊື່ອມຕໍ່ເຄືອຂ່າຍ

  1. Connect a standard Ethernet cable from the PDU's network port to your network switch or router.
  2. The PDU will obtain an IP address via DHCP by default. Refer to the full user manual for static IP configuration.

ຄໍາແນະນໍາການດໍາເນີນງານ

Powering On/Off Connected Devices

Once the PDU is powered and connected to the network, you can manage its outlets remotely.

  1. Access the PDU's web ການໂຕ້ຕອບໂດຍການໃສ່ທີ່ຢູ່ IP ຂອງມັນເຂົ້າໄປໃນ a web ຕົວທ່ອງເວັບ.
  2. Log in using the default credentials (refer to the full manual for details).
  3. Navigate to the outlet control section. From here, you can individually switch on, switch off, or cycle power to each of the 16 C13 outlets.

Monitoring Current Draw

ໄດ້ web interface also provides real-time monitoring of the aggregate current draw. This allows you to ensure that the PDU and its connected circuit are not overloaded.

ບໍາລຸງຮັກສາ

  • ທໍາຄວາມສະອາດ: Periodically clean the exterior of the PDU with a soft, dry cloth. Do not use liquid cleaners or solvents.
  • ການອັບເດດເຟີມແວ: Check the APC website for available firmware updates to ensure optimal performance and security. Follow the instructions provided with the firmware package for safe updating.
  • ການຄຸ້ມຄອງສາຍໄຟ: Ensure all power and network cables are neatly routed and secured to prevent accidental disconnections or damage.

ການແກ້ໄຂບັນຫາ

ບັນຫາສາເຫດທີ່ເປັນໄປໄດ້ການແກ້ໄຂ
PDU does not power on.No input power; tripped circuit breaker.Verify the power cord is securely connected. Check the building's circuit breaker for the PDU's power source.
ບໍ່ສາມາດເຂົ້າເຖິງໄດ້ web ການໂຕ້ຕອບ.Incorrect IP address; network connectivity issue; PDU not powered.Ensure the PDU is powered on. Verify network cable connection. Confirm the correct IP address. Check network settings.
Outlets do not switch.Software issue; PDU fault.Try restarting the PDU. If the issue persists, contact technical support.
ສັນຍານເຕືອນເກີນ.Total current draw exceeds PDU rating.Disconnect non-essential equipment to reduce the load. Redistribute equipment across multiple PDUs if necessary.

ຂໍ້ມູນຈໍາເພາະ

ຄຸນສົມບັດລາຍລະອຽດ
ໝາຍເລກຕົວແບບAP7922
ຍີ່ຫໍ້APC ໂດຍ Schneider Electric
ປັດໄຈແບບຟອມ2U Rack-mountable, 19-inch
ການປ້ອນຂໍ້ມູນ Voltage230 វ៉ុល AC
ປະຈຸບັນການປ້ອນຂໍ້ມູນ32 Amps
ຜົນໄດ້ຮັບ Voltage230 វ៉ុល AC
ປະຈຸບັນຜົນຜະລິດ32 Amps (ສູງສຸດ)
ຈໍານວນຮ້ານຂາຍ16
ປະເພດຕົວເຊື່ອມຕໍ່C13
ການເຊື່ອມໂຍງເຄືອຂ່າຍອີເທີເນັດ 10/100
ວັດtage7360 ວັດ
ຂະໜາດ (H x W x D)4.49 x 17.52 x 3.5 ນິ້ວ
ນ້ຳໜັກ0.7 ກິ​ໂລກ​ຣາມ
ວັດສະດຸໂລຫະ
ສີດຳ

ການຮັບປະກັນແລະການສະຫນັບສະຫນູນ

ຂໍ້ມູນການຮັບປະກັນ

APC products typically come with a standard manufacturer's warranty. Please refer to the warranty card included with your product or visit the official APC website for detailed warranty terms and conditions specific to the AP7922 model.

ສະຫນັບສະຫນູນດ້ານວິຊາການ

For technical assistance, troubleshooting, or to report issues, please contact APC customer support. You can find contact information and additional resources on the official Schneider Electric webເວັບໄຊ:

APC by Schneider Electric Official Webເວັບໄຊ

© 2023 APC by Schneider Electric. All rights reserved. Information in this document is subject to change without notice.